No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 29-11-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0454/W03/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect Namevivek raj gupta
License No.SINPC/ENG/0001/2022
Architect AddressPRINCE CHOWK,SIMDEGA ,JHARKHAND
Architect EmailIDvivekgupta553@gmail.com
Architect Mobile No7008039097
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1147
NorthPlot No. - 1147
SouthPlot No. - 11477
EastPlot No. - 1147
WestRoad Width - 3.6
Owner's Details
NamePRAPHULITA AIND ANTHONY
AddressSALDEGA
Email IDJHON12@GMAIL.COM
Mobile No9821738485
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 525.81
2 Physical area measured at site 525.81
3Area as per Drawing 525.81

Area of Plot Considered : 525.81

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 525.81
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 525.81
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 488.13
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 37.67
37.67
Balance Plot Area 488.13

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 315.49
Proposed Coverage Area ( 17.63 % ) 92.70
Total Prop. Coverage Area ( 17.63 % ) 92.70
Balance coverage area ( 42.37 % ) 222.79
FAR CHECK
Perm. FAR Area ( 1.500 ) 788.71
Total Perm. FAR area 788.71
Residential FAR 185.41
Proposed FAR Area 185.41
Total Proposed FAR Area 185.41
Consumed FAR (Factor) 0.35
Balance FAR Area 603.30
BUA CHECK
Total Proposed BuiltUp Area 185.40


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 3.60
Proposed Road Width as per Master Plan -
Road Widening Width -
Plot size (as per measurement) 525.81

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 525.81 OK
Plot Width Mt. - - 15.37 OK
Plot Depth Mt. - - 34.21 OK
Access Width Mt. - - 3.60 OK
Plot Frontage Mt. - - 15.37 OK
Coverage Area Sq.Mt. - 315.49 92.70 OK
FAR Area Sq.Mt. - 788.71 185.41 OK
Consumed FAR Sq.Mt. - 1.50 0.35 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 26.29 37.67 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 37.67 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.95 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 25.00 - 25.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 9.08 OK
A-1 (BUILDING) Front Margin... 3.6 M MAIN ROAD Mt. 4.00 - 18.41 OK
Rear Margin Mt. 3.00 - 5.10 OK
Side1 Margin Mt. 1.00 - 1.50 OK
Side2 Margin Mt. 1.00 - 1.67 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 10.00 6.20 OK
A (BUILDING) First Floor - Height Mt. 2.75 - 3.10 OK
First Floor - Clear Height Mt. 2.75 - 3.00 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Ground Floor - Height Mt. 2.75 - 3.10 OK
Ground Floor - Clear Height Mt. 2.75 - 3.00 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.200 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 8.91 OK
Width Mt. - - 2.38 OK
Depth Mt. - - 3.74 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 4.06 OK
Width Mt. - - 1.45 OK
Depth Mt. - - 2.81 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 3.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)