No Image Found   

Failed List Report

Simdega Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 29-08-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0441/W07/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKhijri
Taluka36
Architect Details
Architect NameMAHENDRA MEHTA
License No.SINPC/DFTMN/0002/2022
Architect AddressRAJ CONSULTANCY, CLUB COMPLEX ,GANDHI MAIDAN MAIN ROAD SIMDEGA
Architect EmailIDrajconsultancysmd@gmail.com
Architect Mobile No9386222833
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No546
North -
South -
East -
West -
Owner's Details
NameKALYAN EKKA
AddressPURNAPANI
Email IDrajconsultancy@gmail.com
Mobile No9386789346
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 101.88
2 Physical area measured at site 101.88
3 Area as per Site Visit (Site Visit Report) 101.88
4Area as per Drawing 101.88

Area of Plot Considered : 101.88

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 101.88
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 101.88
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 93.95
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 7.93
7.93
Balance Plot Area 93.95

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 71.32
Proposed Coverage Area ( 46.76 % ) 47.64
Total Prop. Coverage Area ( 46.76 % ) 47.64
Balance coverage area ( 23.24 % ) 23.68
FAR CHECK
Perm. FAR Area ( 1.800 ) 183.38
Total Perm. FAR area 183.38
Residential FAR 142.93
Proposed FAR Area 142.93
Total Proposed FAR Area 142.93
Consumed FAR (Factor) 1.40
Balance FAR Area 40.45
BUA CHECK
Total Proposed BuiltUp Area 142.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.09 6.09
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 101.88 101.88


   
   

[-] Building:A1 (RESIDENTIAL)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:SECOND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop


   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)