No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 10-07-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0518/W04/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect NameDEELIP KUMAR
License No.SINPC/DFTMN/0003/2023
Architect AddressRAJ CONSULTANCY CLUB COMPLEX GANDHI MAIDAN, MAIN ROAD, SIMDEGA
Architect EmailIDrajconsultancysmd@gmail.com
Architect Mobile No9386222833
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1393
North -
South -
East -
West -
Owner's Details
NameDAVID KANDULNA JOHN KANDULNA
AddressSALDEGA PAHAN TOLI
Email IDkandulnadavid423@gmail.com
Mobile No9608728952
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1214.15
2 Plot area as per Document by Applicant 1214.15
3 Area as per Site Visit (Site Visit Report) 1214.15
4Area as per Drawing 1214.15

Area of Plot Considered : 1214.15

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1214.15
Deduction from Gross Plot area
- Surrender Free of Cost 110.64
110.64
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1103.51
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1047.98
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 110.64
- Common Plot 55.52
166.16
Balance Plot Area 1047.98

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 551.76
Proposed Coverage Area ( 11.85 % ) 130.81
Total Prop. Coverage Area ( 11.85 % ) 130.81
Balance coverage area ( 38.15 % ) 420.95
FAR CHECK
Perm. FAR Area ( 2.000 ) 2428.30
Total Perm. FAR area 2428.30
Residential FAR 265.62
Proposed FAR Area 265.62
Total Proposed FAR Area 265.62
Consumed FAR (Factor) 0.22
Balance FAR Area 2162.68
BUA CHECK
Total Proposed BuiltUp Area 265.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 2.33
Plot size (as per measurement) 1214.15 1214.15
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 1103.51 OK
Plot Width Mt. - - 47.42 OK
Plot Depth Mt. - - 23.27 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 47.42 OK
Coverage Area Sq.Mt. - 551.76 130.81 OK
FAR Area Sq.Mt. - 2428.30 265.62 OK
Consumed FAR Sq.Mt. - 2.00 0.22 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 55.18 55.52 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 55.52 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.83 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 12 OK
Car In Area Sq.Mt. - - 31.08 OK
Total Car In Area Sq.Mt. 25.00 - 31.08 OK
Visitor's Car Parking In Area Sq.Mt. - - 15.54 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 15.54 OK
TwoWheeler In Area Sq.Mt. - - 6.22 OK
Total TwoWheeler In Area Sq.Mt. - - 6.22 OK
DriveWay PLOT - - - DRIVE WAY - Width No. 3.60 - 6.22 OK
A1-1 (RESIDENTIAL) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 6.24 OK
Rear Margin Mt. 1.80 - 3.03 OK
Side1 Margin Mt. 3.66 - 4.87 OK
Side2 Margin Mt. 3.66 - 31.48 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A1 (RESIDENTIAL) Height Mt. 16.40 6.05 OK
A1 (RESIDENTIAL) First Floor - Height Mt. 2.75 - 3.02 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Ground Floor - Height Mt. 2.75 - 3.02 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Plinth - Height Mt. 0.45 - 0.61 OK
Plinth - Clear Height Mt. - - 0.61 OK
Plinth - Beam Clear Height Mt. - - 0.61 OK
A1 (RESIDENTIAL) Terrace Floor - Height Mt. - - 0.91 OK
Terrace Floor - Clear Height Mt. - - 0.91 OK
Terrace Floor - Beam Clear Height Mt. - - 0.91 OK
A1 (RESIDENTIAL) No. of Floors No. G + 4 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.067 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.168 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.067 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.168 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.067 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.540 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.93 OK
Width Mt. - - 1.94 OK
Depth Mt. - - 3.05 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 16.36 OK
Width Mt. - - 2.01 OK
Depth Mt. - - 8.16 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.84 OK
Width Mt. - - 1.89 OK
Depth Mt. - - 3.10 OK
Height Mt. - - - OK
A1 (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 45 mt. or above, Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 3.66 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room2.18x1.07 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.78x3.38 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall2.29x3.53 No Rule Defined
Hall2.46x3.20 No Rule Defined
Kitchen2.43x3.20 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen2.44x2.87 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen3.78x2.31 Area for Kitchen when store room is provided shall be Mini. 4.5 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Toilet1.37x3.20 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.37x3.53 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}