No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 09-08-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0515/W14/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect NameRAWNIT KUMAR
License No.SINPC/ENG/0004/2020
Architect AddressVILL-PALKOT,PS-PALKOT PO-PALKOT
Architect EmailIDrawnitkumar5@gmail.com
Architect Mobile No6200132032
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No720,722,727
North -
South -
East -
West -
Owner's Details
NamePAWAN KUMAR MITTAL
AddressMITTAL GALI SIMDEGA
Email IDmedicinehouse568@gmail.com
Mobile No7488002058
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 416.98
2 Plot area as per Document by Applicant 416.98
3 Physical area measured at site 416.98
4 Area as per Site Visit (Site Visit Report) 416.98
5Area as per Drawing 416.98

Area of Plot Considered : 416.98

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 416.98
Deduction from Gross Plot area
- Surrender Free of Cost 16.28
16.28
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 400.70
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 356.64
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 16.28
- Common Plot 44.06
60.34
Balance Plot Area 356.64

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 240.42
Proposed Coverage Area ( 63.59 % ) 254.81
Total Prop. Coverage Area ( 63.59 % ) 254.81
Balance coverage area ( - % ) 0.00
FAR CHECK
Perm. FAR Area ( 1.500 ) 625.47
Total Perm. FAR area 625.47
Residential FAR 631.65
Proposed FAR Area 631.65
Total Proposed FAR Area 631.65
Consumed FAR (Factor) 1.51
Balance FAR Area 0.00
Total Paid Proposed FAR Area 6.18
BUA CHECK
Total Proposed BuiltUp Area 751.26


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.66 3.66
Proposed Road Width as per Master Plan 3.66 -
Road Widening Width 0 1.97
Plot size (as per measurement) 416.98 416.98
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 400.70 OK
Plot Width Mt. - - 7.82 OK
Plot Depth Mt. - - 51.25 OK
Access Width Mt. - - 3.66 OK
Plot Frontage Mt. - - 8.25 OK
Coverage Area Sq.Mt. - 240.42 254.81 Failed
FAR Area Sq.Mt. - 625.47 631.65 Failed
Consumed FAR Sq.Mt. - 1.50 1.51 Failed
Common Plot Checks Common Plot - Total Area Sq.Mt. 20.04 44.06 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 44.06 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.26 OK
Tree Cover (Plantation) - Angle Degree - 86.07 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 14 OK
A-1 (SRI PAWAN KUMAR MITTAL) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 4.00 - 2.47 Failed
Rear Margin Mt. 4.00 - 3.14 Failed
Side1 Margin Mt. - - 0.86 OK
Side2 Margin Mt. 0.90 - 0.90 OK
A-1 (SRI PAWAN KUMAR MITTAL) BldgLine for 3.66 MTR WIDE MAINROAD Mt. 0.72 4.46 OK
A-1 (SRI PAWAN KUMAR MITTAL) ResvRoad Width Check for... 3.66 MTR WIDE MAINROAD Mt. 0.72 1.99 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI PAWAN KUMAR MITTAL) Height Mt. 9.95 9.16 OK
A (SRI PAWAN KUMAR MITTAL) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.96 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.96 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.96 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Plinth - Height Mt. 0.45 - 0.57 OK
Plinth - Clear Height Mt. - - 0.57 OK
Plinth - Beam Clear Height Mt. - - 0.57 OK
A (SRI PAWAN KUMAR MITTAL) Terrace Floor - Height Mt. - - 0.99 OK
Terrace Floor - Clear Height Mt. - - 0.99 OK
Terrace Floor - Beam Clear Height Mt. - - 0.99 OK
A (SRI PAWAN KUMAR MITTAL) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.196 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1 & 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.196 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.196 OK
STAIRCASE - Tread Width Mt. - 0.255 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.444 OK
SewageTreatment Plant Area Sq.Mt. - - 1.07 OK
Width Mt. - - 0.83 OK
Depth Mt. - - 1.29 OK
Height Mt. - - - OK
RAINWATERHARVESTING Area Sq.Mt. - - 0.66 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 0.89 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.04 OK
Width Mt. - - 0.43 OK
Depth Mt. - - 2.43 OK
Height Mt. - - - OK
SOLARHEATINGSYSTEM Area Sq.Mt. - - 1.23 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.61 OK
Height Mt. - - - OK
A (SRI PAWAN KUMAR MITTAL) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - Width Mt. - 0.75 OK
0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - Depth Mt. - 0.15 OK
0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (SRI PAWAN KUMAR MITTAL) - GROUND FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SewageTreatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAINWATERHARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLARHEATINGSYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room2.96x3.35 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.00x4.43 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.02x3.35 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.54x4.43 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dining2.19x9.08 No Rule Defined
Dining3.32x3.18 No Rule Defined
Drawing Room3.09x4.98 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Drawing Room4.66x8.65 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Kitchen1.80x4.28 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Sitout5.05x1.21 No Rule Defined
Sitout5.84x1.20 No Rule Defined
Study Room2.20x4.43 No Rule Defined
Toilet1.20x3.05 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.96x1.37 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet3.02x1.37 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}