-
No Image Found

Check List Report

Seraikela Nagar Panchayat

Version Number: 1.0.29
Version Date: 30/06/2018
Report Generated On: 11-10-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0033/W03/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHatsai
Taluka37
Architect Details
Architect NameL K SUMAN
License No.SNPC/ENG/0009/2018
Architect AddressSHOP NO-01 2ND FLOOR BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Commercial
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No137
NorthRoad Width - 12.1
SouthSurvey No. - Niz Land
EastSurvey No. - Weekly Haat
WestSurvey No. - Other Plot
Owner's Details
NameSRI BIRBIKRAM SINGH DEO AND SRI SURBIKRAM SINGH DEO
AddressNUA PAKA 1 SERAIKELA
Email ID004debeshsinghdeo@gmail.com
Mobile No9097022171
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1254.98
2 Plot area as per Document by Applicant 807.85
3 Physical area measured at site 807.85
4 Area as per Site Visit (Site Visit Report) 807.85
5Area as per Drawing 807.85

Area of Plot Considered : 807.85

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 807.85
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 807.85
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 716.83
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 91.02
91.02
Balance Plot Area 716.83

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 403.92
Proposed Coverage Area ( 41.56 % ) 335.71
Total Prop. Coverage Area ( 41.56 % ) 335.71
Balance coverage area ( 8.44 % ) 68.21
FAR CHECK
Perm. FAR Area ( 2.00 ) 1615.70
Total Perm. FAR area 1615.70
Residential FAR 280.85
Commercial FAR 667.11
Proposed FAR Area 947.96
Total Proposed FAR Area 947.96
Consumed FAR (Factor) 1.17
Balance FAR Area 667.74
BUA CHECK
Total Proposed BuiltUp Area 962.13


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.1 12.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 807.85 807.85


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 807.85 OK
Plot Width Sq.Mt. - - 20.73 OK
Plot Depth Sq.Mt. - - 38.97 OK
Access Width Sq.Mt. - - 12.10 OK
Plot Frontage Sq.Mt. - - 20.73 OK
Coverage Area Sq.Mt. - 403.92 335.71 OK
FAR Area Sq.Mt. - 1615.70 947.96 OK
Consumed FAR Sq.Mt. - 2.00 1.17 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 80.78 91.02 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 91.02 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.47 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 75.00 - 75.00 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. 14.00 - 24.00 OK
A-1 (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Front Margin... 12.1 M WIDE R O A D Mt. 7.00 - 7.00 OK
Rear Margin Mt. 4.50 - 4.52 OK
Side1 Margin Mt. 2.50 - 6.00 OK
Side2 Margin Mt. 2.50 - 2.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Height Mt. 23.10 9.00 OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Second Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Terrace Floor - Height Mt. 1.00 1.20 1.20 OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 3 OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Number Of Lift(s) No. - 1 OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) GROUND FLOOR PLAN - LIFT - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - LIFT - Depth Mt. 1.90 2.40 OK
FIRST FLOOR PLAN - LIFT - Width Mt. 1.70 1.80 OK
FIRST FLOOR PLAN - LIFT - Depth Mt. 1.90 2.40 OK
SECOND FLOOR PLAN - LIFT - Width Mt. 1.70 1.80 OK
SECOND FLOOR PLAN - LIFT - Depth Mt. 1.90 2.40 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.80 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.40 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.200 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 1.200 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.12 OK
Width Mt. - - 1.71 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.69 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
A (BIRBIKRAM SINGHDEO AND SURBIKRAM SINGHDEO) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)