No Image Found

Detail Scrutiny Report

Seraikela Nagar Panchayat

Version Number: 1.0.32
Version Date: 10/05/2018
Report Generated On: 05-02-2019
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0027/W03/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHansahudi
Taluka37
Architect Details
Architect NameL K SUMAN
License No.SNPC/ENG/0009/2018
Architect AddressSHOP NO-01 2ND FLOOR BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Other Residential Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No61/A, 63/A
NorthPlot No. - Hiralal Pradhan
SouthPlot No. - Seller Nij, Devender Uraon
EastRoad Width - 5.0
WestSurvey No. - Seller NIj
Owner's Details
NameSri Jyoti Lal Mahato
AddressAdarsh Colony Seraikela
Email IDjyotilal25@gmail.com
Mobile No8709001034
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 202.50
2 Plot area as per Document by Applicant 202.00
3 Physical area measured at site 202.00
4 Area as per Site Visit (Site Visit Report) 202.00
5Area as per Drawing 201.85

Area of Plot Considered : 201.85

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED BUILDING
Plot OccupancyResidential
Plot SubUse Other Residential Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 201.85
Deduction from Gross Plot area
- Extra Land Area 9.96
9.96
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 191.89
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 169.51
Deductions for Balance Plot Area (from Gross Plot Area)
- Extra Land Area 9.96
- Common Plot 22.37
32.34
Balance Plot Area 169.51

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 134.32
Proposed Coverage Area ( 39.49 % ) 75.78
Total Prop. Coverage Area ( 39.49 % ) 75.78
Balance coverage area ( 30.51 % ) 58.54
FAR CHECK
Perm. FAR Area ( 1.50 ) 287.83
Total Perm. FAR area 287.83
Residential FAR 75.78
Proposed FAR Area 75.78
Total Proposed FAR Area 75.78
Consumed FAR (Factor) 0.39
Balance FAR Area 212.05
BUA CHECK
Total Proposed BuiltUp Area 75.78


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4 4.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 0.76
Plot size (as per measurement) 202 201.85



[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 9.59 22.37 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 22.37 0.00 0.00 - 2.33 - 90.00 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (JYOTILAL MAHATO) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (JYOTILAL MAHATO) 10.00 3.30 3.30 3.30 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (JYOTILAL MAHATO) Ground Floor 2.75 - 3.30 2.75 - 3.19 2.40 - 2.96 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (JYOTILAL MAHATO) Terrace Floor 1.00 1.20 1.10 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (JYOTILAL MAHATO) G + 2 1 - 1 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
134.32 75.78 OK
70% 39.49%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (JYOTILAL MAHATO) - 75.78
Total Prop. Coverage Area - 75.78
Total Coverage Area 134.32 75.78

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (JYOTILAL MAHATO) 1 75.78 75.78 75.78 75.78 01
Grand Total : 1 75.78 75.78 75.78 75.78 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (JYOTILAL MAHATO)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 75.78 75.78 75.78 75.78
Terrace Floor 0.00 0.00 0.00 0.00
Total : 75.78 75.78 75.78 75.78


[-] UnitBUA Table for Building :A (JYOTILAL MAHATO) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN A FLAT 75.78 67.42 7 1
Total: - - 75.78 67.42 7 1


[-] Building :A (JYOTILAL MAHATO)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 75.78 75.78 75.78 75.78 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 75.78 75.78 75.78 75.78 01
Total Number of Same Buildings : 1
Total : 75.78 75.78 75.78 75.78 01
[-] Table 4c-2

FARArea
Building FAR Area:75.78
Existing FAR Area :0.00
Perm.
287.83
Prop.
75.78
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (JYOTILAL MAHATO) Extra Land 2.00 5.03 1.50 1.53 0.90 0.92 0.90 2.44 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (JYOTILAL MAHATO) BldgLine for 4.0 M WIDE ROAD 0.55 5.79 4.0 M WIDE ROAD Extra Land 0.55 0.76 Ok





[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.


[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (JYOTILAL MAHATO)


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (JYOTILAL MAHATO)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.900 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK



[-] Floor Details (Table 9)


[-] Building:A (JYOTILAL MAHATO)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.




[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 191.89 OK
Plot Width - 13.11 OK
Plot Depth - 14.64 OK
Access Width - 4.00 OK
Plot Frontage - 13.11 OK
Coverage Area 134.32 75.78 OK
FARArea
Bldg. FAR Area : 75.78
Sanctioned FAR Area :0.00
287.83 75.78 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Building Level (Rooms)