No Image Found

Failed List Report

Seraikela Nagar Panchayat

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 29-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District SERAIKELA
Authority SARAIKELA NAGAR PANCHAYAT
Inward_No SNPC/BP/0035/W04/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Hansahudi
Taluka 37
Architect Details
Architect Name L K SUMAN
License No. SNPC/ENG/0009/2018
Architect Address SHOP NO-01 2ND FLOOR BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR
Architect EmailID lksumanoffice@gmail.com
Architect Mobile No 9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 308/A
North Survey No. - Kiran Devi
South Plot No. - 308
East Road Width - 3.66
West Plot No. - 302
Owner's Details
Name Smt. Namita Singh
Address Hansahudi, Seraikela
Email ID namitaseraikela@gmail.com
Mobile No 9006283004
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 202.40
2 Plot area as per Document by Applicant 198.51
3 Physical area measured at site 198.51
4 Area as per Site Visit (Site Visit Report) 198.51
5 Area as per Drawing 198.51

Area of Plot Considered : 198.51

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot \OPROPOSED BUILDING
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 198.51
Deduction from Gross Plot area
- Extra Land Area 6.24
6.24
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 192.27
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 171.99
Deductions for Balance Plot Area (from Gross Plot Area)
- Extra Land Area 6.24
- Common Plot 20.28
26.52
Balance Plot Area 171.99

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 134.59
Proposed Coverage Area ( 45.07 % ) 86.66
Total Prop. Coverage Area ( 45.07 % ) 86.66
Balance coverage area ( 24.93 % ) 47.93
FAR CHECK
Perm. FAR Area ( 1.50 ) 288.40
Total Perm. FAR area 288.40
Residential FAR 173.33
Proposed FAR Area 173.33
Total Proposed FAR Area 173.33
Consumed FAR (Factor) 0.90
Balance FAR Area 115.07
BUA CHECK
Total Proposed BuiltUp Area 173.32


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.66 3.66
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 0.72
Plot size (as per measurement) 198.51 198.51





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)