No Image Found

Detail Scrutiny Report

Seraikela Nagar Panchayat

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 21-07-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0014/W04/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageHansahudi
Taluka37
Architect Details
Architect NameDURGA PRASAD DUBEY
License No.SNPC/ENG/0004/2017
Architect AddressAT-WARD 05 KABIKUTIR,SERAIKELLA
Architect EmailIDdpdubeyseraikella@gmail.com
Architect Mobile No9234758068
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No521,522
NorthRoad Width - 7.32
SouthPlot No. - ISHWAR CHANDRA
EastPlot No. - TARAPAD TRIPATHY
WestPlot No. - NIJ EXT.HOUSE
Owner's Details
NamePANKAJINI DUBEY
AddressAT WARD NO-01 HENSAHUDI SERAIKELLA PS-SERAIKELLA,PO-SERAIKELLA
Email IDpinayakdubey48@gmail.com
Mobile No9234719800
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 890.28
2 Plot area as per Document by Applicant 890.28
3 Physical area measured at site 890.28
4 Area as per Site Visit (Site Visit Report) 890.28
5Area as per Drawing 490.26

Area of Plot Considered : 490.26

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 490.26
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 490.26
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 397.30
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 92.96
92.96
Balance Plot Area 397.30

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 294.16
Proposed Coverage Area ( 31.74 % ) 155.62
Total Prop. Coverage Area ( 31.74 % ) 155.62
Balance coverage area ( 28.26 % ) 138.54
FAR CHECK
Perm. FAR Area ( 2.00 ) 980.52
Total Perm. FAR area 980.52
Residential FAR 155.62
Proposed FAR Area 155.62
Total Proposed FAR Area 155.62
Consumed FAR (Factor) 0.32
Balance FAR Area 824.90
BUA CHECK
Total Proposed BuiltUp Area 155.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.32 7.32
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 890.28 490.26




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 49.03 92.96 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 92.96 0.00 0.00 - 4.15 - 89.75 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 4 OK



[-] Drawing Checkings

No Rule Status
1 Setback is not checked as per Rule, Please check the Drawing again. Failed

Notice: Please correct the failed entity, you may have the wrong result due to improper drawing.



[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 16.40 0.00 0.00 3.26 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Ground Floor 2.75 - 3.26 OK
Plinth 0.45 - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 4 1 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
294.16 155.62 OK
60% 31.74%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (BUILDING) - 155.62
Total Prop. Coverage Area - 155.62
Total Coverage Area 294.16 155.62


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BUILDING) 1 155.62 155.62 155.62 155.62 01
Grand Total : 1 155.62 155.62 155.62 155.62 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 155.62 155.62 155.62 155.62
Terrace Floor 0.00 0.00 0.00 0.00
Total : 155.62 155.62 155.62 155.62


[-] UnitBUA Table for Building :A (BUILDING) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT SPLIT FLAT 155.62 133.35 11 1
Total: - - 155.62 133.35 11 1


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 155.62 155.62 155.62 155.62 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 155.62 155.62 155.62 155.62 01
Total Number of Same Buildings : 1
Total : 155.62 155.62 155.62 155.62 01

[-] Table 4c-2

FARArea
Building FAR Area:155.62
Existing FAR Area :0.00
Perm.
980.52
Prop.
155.62
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BUILDING)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.200 0.225 0.250 0.200 0.148 - 8 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.200 - 0.250 - 0.000 - 0 2.100 - 2.400 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 2.88 - - 1.20 - - 2.40 - - 0.00 OK
ENT.GATE - - 1.05 - - 0.22 - - 4.68 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.88 - - 1.20 - - 2.40 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK




[-] Floor Details (Table 9)


[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 490.26 OK
Plot Width - 21.89 OK
Plot Depth - 22.39 OK
Access Width - 7.32 OK
Plot Frontage - 21.55 OK
Coverage Area 294.16 155.62 OK
FARArea
Bldg. FAR Area : 155.62
Sanctioned FAR Area :0.00
980.52 155.62 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For new area, on Road width 6.1-7.5 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For new area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 16}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)