Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Plot Width |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Plot Depth |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Access Width |
The minimum width of abutting road shall not be less than 6.1 mt. {As per Rule no. 61.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Plot Frontage |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
FAR Area |
(1)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
|
Consumed FAR |
(1)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
;
(2)
;
(3)
; ;
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
Affordable Housing having bldg ht. 10-12 mt.,no of floors as G+3, Plot Depth 33-45 mt. and Plot width 45 mt. or above, Margin required in Front shall be 4.5 mt., Rear 3.0 mt. and 4.0 mt. shall be provided on both side.
|
PWork to PWork Margin |
For Affordable Housing, Reqd Building to Building margin shall be 4.5 mt. or 1/4th of height of Building whichever is high {As per Rule No. 83.11}
|
Building Level |
Building Height |
For Affordable Housing, No height limitation shall be applicable {As per Chapter XI}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4)
The height of Plinth floor for Affordable Housing shall be Min. height 30 cm. from the surrounding ground level {As per Rule No. 83.18}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Floor Number |
For Affordable Housing, No floor number limitation shall be applicable {As per Chapter XI}
|
Balcony |
Projected balcony may be allowed on first floor subject to condition that the side and rear setback of the Building is more than 4.5 mt. and 4.5m. clear driveway is available for Fire movement. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Passage |
No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Arch Projection |
(1)
No need to check
(2)
Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
|
Plot / Building Level |
Accessory Use |
(1)
-
(2)
No need to check distance from Building Sewage Treatment Plant
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4)
No need to check distance from Building RAIN WATER HARVESTING
(5)
No need to check distance from Building ENT.GATE
(6)
-
(7)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Accessory Use Number |
(1)
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2)
For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |