General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0009/W01/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGutusai
Taluka37
Architect Details
Architect NameANITA KUMARI
License No.SNPC/ENG/0019/2020
Architect AddressHari Har Mall, Birsa Chowk, Seraikela
Architect EmailIDcdcs00108@gmail.com
Architect Mobile No7001652241
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No293/A
NorthPlot No. - 290
SouthPlot No. - 292
EastPlot No. - 292
WestRoad Width - 3.66
Owner's Details
NameSUMITRA TIU
AddressANJANI NAGAR SERAIKELA
Email IDbikkidas09@gmail.com
Mobile No9199591314
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 139.21
2 Plot area as per Document by Applicant 139.21
3 Area as per Site Visit (Site Visit Report) 139.21
4Area as per Drawing 139.35

Area of Plot Considered : 139.21

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 139.21
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 139.21
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 131.21
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 8.00
8.00
Balance Plot Area 131.21

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 97.45
Proposed Coverage Area ( 59.06 % ) 82.22
Total Prop. Coverage Area ( 59.06 % ) 82.22
Balance coverage area ( 10.94 % ) 15.23
FAR CHECK
Perm. FAR Area ( 1.50 ) 208.82
Total Perm. FAR area 208.82
Residential FAR 164.45
Proposed FAR Area 164.45
Total Proposed FAR Area 164.45
Consumed FAR (Factor) 1.18
Balance FAR Area 44.37
BUA CHECK
Total Proposed BuiltUp Area 164.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.66 3.66
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 139.21 139.35
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 139.21 OK
Plot Width Mt. - - 9.14 OK
Plot Depth Mt. - - 15.24 OK
Access Width Mt. - - 3.66 OK
Plot Frontage Mt. - - 9.14 OK
Coverage Area Sq.Mt. - 97.45 82.22 OK
FAR Area Sq.Mt. - 208.82 164.45 OK
Consumed FAR Sq.Mt. - 1.50 1.18 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 6.96 8.00 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 8.00 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 13 OK
TIU-1 (SUMITRA) Front Margin... 3.66M MAIN ROAD Access Road Mt. 2.50 - 2.48 Failed
Rear Margin Mt. 1.50 - 1.52 OK
Side1 Margin Mt. 0.90 - 0.93 OK
Side2 Margin Mt. - - 0.90 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
TIU (SUMITRA) Height Mt. 7.97 6.40 OK
TIU (SUMITRA) First Floor - Height Mt. 2.75 - 3.20 OK
First Floor - Clear Height Mt. 2.75 - 3.05 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.90 OK
Existing Ground Floor - Height Mt. 2.75 - 3.20 OK
Existing Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Existing Ground Floor - Beam Clear Height Mt. 2.40 - 2.90 OK
Plinth - Height Mt. 0.45 - 0.46 OK
Plinth - Clear Height Mt. - - 0.46 OK
Plinth - Beam Clear Height Mt. - - 0.46 OK
TIU (SUMITRA) Terrace Floor - Height Mt. - - 1.00 OK
TIU (SUMITRA) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.016 OK
STAIRCASE - Tread Width Mt. 0.225 0.229 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 4.58 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 3.01 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.67 OK
Width Mt. - - 1.46 OK
Depth Mt. - - 1.46 OK
Height Mt. - - - OK
TIU (SUMITRA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)