-
No Image Found   

Check List Report

Seraikela Nagar Panchayat

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 29-01-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0005/W07/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageIndritandi
Taluka37
Architect Details
Architect NameDURGA PRASAD DUBEY
License No.SNPC/ENG/0004/2017
Architect AddressAT-WARD 05 KABIKUTIR,SERAIKELLA
Architect EmailIDdpdubeyseraikella@gmail.com
Architect Mobile No9234758068
Plot Details
Plot Use Residential
Plot SubUse Other Residential Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No584
NorthRoad Width - 6.09
SouthPlot No. - 586
EastPlot No. - NIJ SHELLERS
WestPlot No. - SUJATA PRADHAN
Owner's Details
NameANJANA JYOTISHI
AddressAT WARD NO 07 (OLD02) INDRATANDI,UNDER NAGAR PANCHAYAT SERAIKELLA
Email IDideasconsulting@yahoo.com
Mobile No9771312904
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 202.33
2 Plot area as per Document by Applicant 202.33
3 Physical area measured at site 202.33
4 Area as per Site Visit (Site Visit Report) 202.33
5Area as per Drawing 202.33

Area of Plot Considered : 202.33

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Other Residential Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 202.33
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 202.33
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 179.49
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 22.84
22.84
Balance Plot Area 179.49

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 141.63
Proposed Coverage Area ( 48.66 % ) 98.45
Total Prop. Coverage Area ( 48.66 % ) 98.45
Balance coverage area ( 21.34 % ) 43.18
FAR CHECK
Perm. FAR Area ( 1.80 ) 364.19
Total Perm. FAR area 364.19
Residential FAR 98.45
Proposed FAR Area 98.45
Total Proposed FAR Area 98.45
Consumed FAR (Factor) 0.49
Balance FAR Area 265.74
BUA CHECK
Total Proposed BuiltUp Area 98.45


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.09 6.09
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 202.33 202.33
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 202.33 OK
Plot Width Mt. - - 11.66 OK
Plot Depth Mt. - - 17.35 OK
Access Width Mt. - - 6.09 OK
Plot Frontage Mt. - - 11.66 OK
Coverage Area Sq.Mt. - 141.63 98.45 OK
FAR Area Sq.Mt. - 364.19 98.45 OK
Consumed FAR Sq.Mt. - 1.80 0.49 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 10.12 22.84 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 22.84 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.03 OK
Tree Cover (Plantation) - Angle Degree - 88.87 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
A-1 (RESIDENTIAL) Front Margin... 6.09 METER WIDE ROAD Mt. 2.50 - 3.89 OK
Rear Margin Mt. 1.50 - 1.51 OK
Side1 Margin Mt. 0.90 - 2.52 OK
Side2 Margin Mt. 0.90 - 0.92 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 10.00 3.16 OK
A (RESIDENTIAL) Ground Floor - Height Mt. 2.75 - 3.16 OK
Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.82 OK
Plinth Floor - Height Mt. 0.45 - 0.61 OK
Plinth Floor - Clear Height Mt. - - 0.61 OK
Plinth Floor - Beam Clear Height Mt. - - 0.61 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. 1.00 1.20 1.02 OK
A (RESIDENTIAL) No. of Floors No. G + 2 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.991 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.991 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.438 OK
Toilet Area Sq.Mt. - 5.00 1.78 OK
Width Mt. - - 1.14 OK
Depth Mt. - - 1.56 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 5.13 OK
Width Mt. - - 1.76 OK
Depth Mt. - - 2.92 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.71 OK
Width Mt. - - 1.14 OK
Depth Mt. - - 1.50 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.70 OK
Width Mt. - - 0.26 OK
Depth Mt. - - 2.72 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.38 OK
Width Mt. - - 0.68 OK
Depth Mt. - - 2.03 OK
Height Mt. - - - OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)