-
No Image Found   

Detail Scrutiny Report

Seraikela Nagar Panchayat

Version Number: 1.0.44  
Version Date: 29/04/2019 
Report Generated On: 29-05-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0014/W02/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePannichatar
Taluka37
Architect Details
Architect NameL K SUMAN
License No.SNPC/ENG/0009/2018
Architect AddressSHOP NO-01 2ND FLOOR BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No133/A, 134/A, 136/A
NorthPlot No. - 134
SouthRoad Width - 3.66 m
EastPlot No. - 135
WestSurvey No. - other plot
Owner's Details
NameMR. NARENDRA SINGH
AddressWARD-2, PANICHATAR SERAIKELA
Email IDexample@gmail.com
Mobile No7033595550
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 456.66
2 Plot area as per Document by Applicant 167.98
3 Physical area measured at site 167.98
4 Area as per Site Visit (Site Visit Report) 167.98
5Area as per Drawing 167.78

Area of Plot Considered : 167.78

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED BUILDING
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 167.78
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 167.78
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 141.87
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.91
25.91
Balance Plot Area 141.87

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 117.45
Proposed Coverage Area ( 68.72 % ) 115.29
Total Prop. Coverage Area ( 68.72 % ) 115.29
Balance coverage area ( 1.29 % ) 2.16
FAR CHECK
Perm. FAR Area ( 1.50 ) 251.67
Total Perm. FAR area 251.67
Residential FAR 230.28
Proposed FAR Area 245.05
Total Proposed FAR Area 245.05
Consumed FAR (Factor) 1.46
Balance FAR Area 6.62
BUA CHECK
Total Proposed BuiltUp Area 345.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.96 3.96
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 167.98 167.78
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 8.39 25.91 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 12.45 0.00 0.00 - 1.52 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 13.46 0.00 0.00 - 0.83 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 4 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (B N TRACTAR) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (B N TRACTAR) 8.44 8.20 8.20 8.20 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (B N TRACTAR) Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.61 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.61 OK
Parking Floor - - 2.50 2.40 - 2.40 2.10 - 2.29 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (B N TRACTAR) Terrace Floor 1.00 1.20 1.12 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (B N TRACTAR) P + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
117.45 115.29 OK
70% 68.72%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (B N TRACTAR) - 115.29
  Total Prop. Coverage Area - 115.29
  Total Coverage Area 117.45 115.29

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Parking Resi. Stair
A (B N TRACTAR) 1 345.56 4.90 95.61 230.28 14.77 245.05 245.05 01
Grand Total : 1 345.56 4.90 95.61 230.28 14.77 245.05 245.05 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (B N TRACTAR)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Parking Floor 115.28 14.77 115.28 14.77
First Floor 115.14 115.14 115.14 115.14
Second Floor 115.14 115.14 115.14 115.14
Terrace Floor 0.00 0.00 0.00 0.00
Total : 345.56 245.05 345.56 245.05


[-] UnitBUA Table for Building :A (B N TRACTAR)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT 230.28 204.59 8 1
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 8 0
Total: - - 230.28 204.59 16 1


[-] Building :A (B N TRACTAR)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Parking Resi. Stair
Parking Floor 115.28 4.90 95.61 0.00 14.77 14.77 14.77 00
First Floor 115.14 0.00 0.00 115.14 0.00 115.14 115.14 01
Second Floor 115.14 0.00 0.00 115.14 0.00 115.14 115.14 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 345.56 4.90 95.61 230.28 14.77 245.05 245.05 01
Total Number of Same Buildings : 1
Total : 345.56 4.90 95.61 230.28 14.77 245.05 245.05 01
[-] Table 4c-2

  FAR Area
Building FAR Area:245.05
Existing FAR Area :0.00
Perm.
251.67
Prop.
245.05
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (B N TRACTAR) 3.96 WIDE ROAD 2.50 2.50 1.50 1.50 - 0.00 0.90 0.94 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (B N TRACTAR)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (B N TRACTAR)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
PARKING FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.254 0.200 0.132 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.254 0.200 0.130 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.220 - 0.254 - 0.000 - 0 - - 2.593 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.254 0.200 0.130 - 11 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 4.90 - - 2.01 - - 2.44 - - 0.00 OK
RAIN WATER HARVESTING - - 1.50 - - 1.00 - - 1.50 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.50 - - 1.00 - - 1.50 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (B N TRACTAR)


[-] Floor:PARKING FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 167.78 OK
  Plot Width - 8.27 OK
  Plot Depth - 20.30 OK
  Access Width - 3.96 OK
  Plot Frontage - 8.27 OK
  Coverage Area 117.45 115.29 OK
  FAR Area
Bldg. FAR Area : 245.05
Sanctioned FAR Area :0.00
251.67 245.05 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)