-
No Image Found   

Detail Scrutiny Report

Seraikela Nagar Panchayat

Version Number: 1.0.52  
Version Date: 16/10/2020 
Report Generated On: 17-12-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0057/W08/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageHatsai
Taluka37
Architect Details
Architect NameNIKHIL SHUKLA
License No.SNPC/ARC/0014/2019
Architect AddressHOUSE NO- 125, CHANAKYAPURI COLONY , OLD PURULIA ROAD , JESU BHAWAN , MANGO, JAMSHEDPUR
Architect EmailIDnikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No14
NorthRoad Width - 6.10
South -
East -
West -
Owner's Details
NameBASANTI MAHATO
AddressRENGOGORA P.O:BURUDIH
Email IDbasantimahato522@gmail.com
Mobile No9955073633
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 303.50
2 Plot area as per Document by Applicant 303.50
3 Physical area measured at site 303.50
4 Area as per Site Visit (Site Visit Report) 303.50
5Area as per Drawing 304.35

Area of Plot Considered : 303.50

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 303.50
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 303.50
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 287.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.95
15.95
Balance Plot Area 287.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 182.10
Proposed Coverage Area ( 51.49 % ) 156.28
Total Prop. Coverage Area ( 51.49 % ) 156.28
Balance coverage area ( 8.51 % ) 25.82
FAR CHECK
Perm. FAR Area ( 2.00 ) 607.00
Total Perm. FAR area 607.00
Residential FAR 301.63
Proposed FAR Area 301.63
Total Proposed FAR Area 301.63
Consumed FAR (Factor) 0.99
Balance FAR Area 305.37
BUA CHECK
Total Proposed BuiltUp Area 319.14


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.66 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 303.5 304.35

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 15.18 15.95 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 5.69 0.00 0.00 - 1.17 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 10.26 0.00 0.00 - 1.43 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 13.87 6.10 6.10 6.54 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) First Floor 2.75 - 3.05 2.75 - 2.93 2.40 - 2.67 OK
Ground Floor 2.75 - 3.05 2.75 - 2.93 2.40 - 2.67 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 4 2 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
182.10 156.28 OK
60% 51.49%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 156.28
  Total Prop. Coverage Area - 156.28
  Total Coverage Area 182.10 156.28

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (BUILDING) 1 319.14 17.50 301.64 301.64 301.64 03
Grand Total : 1 319.14 17.50 301.64 301.64 301.64 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 156.29 138.79 156.29 138.79
First Floor 162.85 162.85 162.85 162.85
Terrace Floor 0.00 0.00 0.00 0.00
Total : 319.14 301.64 319.14 301.64


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN UNIT-1 FLAT 138.79 138.33 14 1
FIRST FLOOR PLAN UNIT-2 FLAT 79.48 78.64 9 2
UNIT-3 FLAT 72.93 71.51 8
Total: - - 291.20 288.49 31 3


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 156.29 17.50 138.79 138.79 138.79 01
First Floor 162.85 0.00 162.85 162.85 162.85 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 319.14 17.50 301.64 301.64 301.64 03
Total Number of Same Buildings : 1
Total : 319.14 17.50 301.64 301.64 301.64 03
[-] Table 4c-2

  FAR Area
Building FAR Area:301.63
Existing FAR Area :0.00
Perm.
607.00
Prop.
301.63
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 6.10M WIDE ROAD 3.00 4.72 1.80 1.83 0.90 1.07 0.90 0.99 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment > 0 1 3.00 1 3 - - - - - - -
> 0 1 3.00 - - - 1 1 - - - -
Total : - - - - 3 3 - 1 0 - 0 3

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 3 37.50 OK
Total Car 3 37.50 3 37.50 OK
Total Visitor Parking 1 12.50 0 0.00 FAILED
TwoWheeler - - 3 6.00 OK
Total TwoWheeler - - 3 6.00 OK
Other Parking - - - 5.00 OK
Total 50.00 54.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.067 0.225 0.267 0.200 0.152 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.067 - 0.267 - 0.000 - 0 2.100 - 2.591 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.067 0.225 0.267 0.200 0.152 - 10 - - 0.000 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (BUILDING)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 2.26 - 1.38 OK
CHHAJJA 0.75 0.61 - 2.26 - 1.38 OK
CHHAJJA 0.75 0.61 - 1.84 - 1.12 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
FIRST FLOOR PLAN CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
CHHAJJA 0.75 0.61 - 1.83 - 1.11 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 3.18 - - 1.64 - - 1.94 - - 0.00 OK
RAIN WATER HARVESTING - - 0.29 - - 0.61 - - 0.61 - - 0.00 OK
ENT.GATE - - 0.76 - - 0.19 - - 4.09 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 0 Failed
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
UNIT-1 TOILET 1.79X1.47 2.80 2.63 1.20 1.47 1.20 1.79 0.30 0.37 Failed

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
UNIT-2 TOILET 1.79X1.47 2.80 2.63 1.20 1.47 1.20 1.79 0.30 0.37 Failed
LIVING/DINING 6.06X1.14 9.50 20.94 2.40 4.53 2.40 6.06 2.09 1.82 Failed
UNIT-3 LIVING/DINING 5.16X3.58 9.50 18.56 2.40 3.58 2.40 5.18 1.86 1.82 Failed


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 303.50 OK
  Plot Width - 12.80 OK
  Plot Depth - 23.77 OK
  Access Width - 6.10 OK
  Plot Frontage - 12.80 OK
  Coverage Area 182.10 156.28 OK
  FAR Area
Bldg. FAR Area : 301.63
Sanctioned FAR Area :0.00
607.00 301.63 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For new area, on Road width 6.1-7.5 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For new area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 16}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)