No Image Found   

Check List Report

Seraikela Nagar Panchayat

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 07-02-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0004/W10/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePannichatar
Taluka37
Architect Details
Architect NameABHISHEK TEWARI
License No.SNPC/ARC/0025/2021
Architect AddressPRITKSHA 23, FORTUNE CITY NEAR N.I.T,JSR P.O- ADITYAPUR INDUSTRIAL AREA
Architect EmailIDabhitewari1984@gmail.com
Architect Mobile No8603677734
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No52/A,51
NorthPlot No. - PORTION PLOT NUMBER- 52
SouthSurvey No. - MOBIN
EastRoad Width - 18
WestPlot No. - PORTION PLOT NUMBER- 52
Owner's Details
NameAKASH KUMAR AGARWAL
AddressPANICHATTAR RAJBANDH SARAIKELA,SAEAIKELA-KHARSWAN
Email IDrammybahl9@gmail.com
Mobile No9334348000
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 405.06
2 Plot area as per Document by Applicant 405.06
3 Physical area measured at site 405.06
4 Area as per Site Visit (Site Visit Report) 405.06
5Area as per Drawing 405.06

Area of Plot Considered : 405.06

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 405.06
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 405.06
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 371.79
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 33.27
33.27
Balance Plot Area 371.79

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 243.04
Proposed Coverage Area ( 53.53 % ) 216.81
Total Prop. Coverage Area ( 53.53 % ) 216.81
Balance coverage area ( 6.48 % ) 26.23
FAR CHECK
Perm. FAR Area ( 2.00 ) 810.12
Total Perm. FAR area 810.12
Residential FAR 806.41
Proposed FAR Area 806.41
Total Proposed FAR Area 806.41
Consumed FAR (Factor) 1.99
Balance FAR Area 3.71
BUA CHECK
Total Proposed BuiltUp Area 921.96


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 18 18.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 405.06 405.06
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 405.06 OK
Plot Width Mt. - - 16.30 OK
Plot Depth Mt. - - 24.85 OK
Access Width Mt. - - 18.00 OK
Plot Frontage Mt. - - 16.93 OK
Coverage Area Sq.Mt. - 243.04 216.81 OK
FAR Area Sq.Mt. - 810.12 806.41 OK
Consumed FAR Sq.Mt. - 2.00 1.99 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 20.25 33.27 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 33.27 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.51 OK
Tree Cover (Plantation) - Angle Degree - 87.66 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 10 OK
A-1 (RESIDENTIAL) Front Margin... 18 METER WIDE MAIN ROAD Mt. 3.00 - 3.55 OK
Rear Margin Mt. 2.25 - 3.30 OK
Side1 Margin Mt. 1.50 - 1.52 OK
Side2 Margin Mt. 1.50 - 1.53 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 30.00 12.00 OK
A (RESIDENTIAL) Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.89 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.89 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.89 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.89 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. - - 1.00 OK
A (RESIDENTIAL) No. of Floors No. - 4 OK
No. of Tenements No. - 1 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.263 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2& 3 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.263 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.263 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.263 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.775 OK
Toilet Area Sq.Mt. - 5.00 0.60 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 0.80 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 0.71 OK
Width Mt. - - 0.83 OK
Depth Mt. - - 0.85 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.95 OK
Width Mt. - - 0.89 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 2.12 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 3.42 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.74 OK
Width Mt. - - 0.81 OK
Depth Mt. - - 0.92 OK
Height Mt. - - - OK
A (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)