No Image Found   

Detail Scrutiny Report

Seraikela Nagar Panchayat

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 11-01-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthoritySARAIKELA NAGAR PANCHAYAT
Inward_NoSNPC/BP/0020/W01/2022/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGutusai
Taluka37
Layout Sanction Date22/4/2022
Architect Details
Architect NameDURGA PRASAD DUBEY
License No.SNPC/ENG/0004/2017
Architect AddressAT-WARD 05 KABIKUTIR,SERAIKELLA
Architect EmailIDdpdubeyseraikella@gmail.com
Architect Mobile No9234758068
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No292
NorthRoad Width - 5
SouthSurvey No. - PAWAN AGARWAL
EastSurvey No. - MADHU PRIYA AND SAJAY VERMA
WestRoad Width - 4
Owner's Details
NameROMI RIMESH AND DILIP KUMAR SAHU
AddressGUTUSAI ANJANI NAGAR,SERAIKELLA
Email IDNIKU.IDEAS@GMAIL.COM
Mobile No7488957279
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 352.87
2 Plot area as per Document by Applicant 352.87
3 Physical area measured at site 352.87
4 Area as per Site Visit (Site Visit Report) 352.87
5Area as per Drawing 352.87

Area of Plot Considered : 352.87

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 352.87
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 352.87
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 289.38
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 63.49
63.49
Balance Plot Area 289.38

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 211.72
Proposed Coverage Area ( 55.15 % ) 194.60
Total Prop. Coverage Area ( 55.15 % ) 194.60
Balance coverage area ( 4.85 % ) 17.12
FAR CHECK
Perm. FAR Area ( 2.000 ) 705.74
Total Perm. FAR area 705.74
Residential FAR 694.01
Proposed FAR Area 705.50
Total Proposed FAR Area 705.50
Consumed FAR (Factor) 2.00
Balance FAR Area 0.24
BUA CHECK
Total Proposed BuiltUp Area 980.52


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 352.87 352.87
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 17.64 63.49 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 63.49 0.00 0.00 - 4.72 - 85.91 4.80 METER WIDE ROAD OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL) 14.32 14.15 14.15 14.15 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Fourth Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Parking Floor - - 2.75 2.40 - 2.65 2.10 - 2.30 OK
Plinth - - 0.46 - - 0.46 - - 0.46 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) P + 4 5 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
211.72 194.60 OK
60% 55.15%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 194.60
  Total Prop. Coverage Area - 194.60
  Total Coverage Area 211.72 194.60

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Accessory Use Parking Resi. Stair
A (RESIDENTIAL) 1 980.52 772.55 207.97 29.28 14.76 50.89 180.10 520.50 173.50 7.80 705.49 705.49 03
Grand Total : 1 980.52 772.55 207.97 29.28 14.76 50.89 180.10 520.50 173.50 7.80 705.49 705.49 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Parking Floor 11.49 183.11 11.49 0.00 11.49 183.11 11.49 0.00
First Floor 0.00 196.48 0.00 173.50 0.00 196.48 0.00 173.50
Second Floor 0.00 196.48 0.00 173.50 0.00 196.48 0.00 173.50
Third Floor 0.00 196.48 0.00 173.50 0.00 196.48 0.00 173.50
Fourth Floor 196.48 0.00 173.50 0.00 196.48 0.00 173.50 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 207.97 772.55 184.99 520.50 207.97 772.55 184.99 520.50


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1- 3 FLOOR PLAN SPLIT A FLAT Existing 544.83 522.09 6 3
SPLIT A FLAT Existing 0.00 0.00 7
SPLIT A FLAT Existing 0.00 0.00 6
FOURTH FLOOR PLAN SPLIT A FLAT Proposed 0.00 0.00 6 0
SPLIT A FLAT Proposed 0.00 0.00 7
SPLIT A FLAT Proposed 0.00 0.00 6
Total: - - - 1634.50 1566.27 76 3


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Accessory Use Parking Resi. Stair
Parking Floor 194.60 183.11 11.49 0.00 0.00 3.01 180.10 0.00 0.00 7.80 11.49 11.49 00
First Floor 196.48 196.48 0.00 7.32 3.69 11.97 0.00 173.50 0.00 0.00 173.50 173.50 01
Second Floor 196.48 196.48 0.00 7.32 3.69 11.97 0.00 173.50 0.00 0.00 173.50 173.50 01
Third Floor 196.48 196.48 0.00 7.32 3.69 11.97 0.00 173.50 0.00 0.00 173.50 173.50 01
Fourth Floor 196.48 0.00 196.48 7.32 3.69 11.97 0.00 0.00 173.50 0.00 173.50 173.50 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 980.52 772.55 207.97 29.28 14.76 50.89 180.10 520.50 173.50 7.80 705.49 705.49 03
Total Number of Same Buildings : 1
Total : 980.52 772.55 207.97 29.28 14.76 50.89 180.10 520.50 173.50 7.80 705.49 705.49 03
[-] Table 4c-2

  FAR Area
Building FAR Area:705.50
Existing FAR Area :0.00
Perm.
705.74
Prop.
705.50
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) 6.10 METER WIDE ROAD 3.50 5.17 2.50 2.50 1.00 1.00 1.00 1.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (RESIDENTIAL) 14.15 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (RESIDENTIAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
PARKING FLOOR PLAN Lift 1.70 1.70 1.90 2.17 OK
FOURTH FLOOR PLAN Lift 1.70 1.70 1.90 2.17 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 2.17 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment > 0 1 3.00 1 3 - - - - - - -
> 0 1 3.00 - - - 1 1 - - - -
Total : - - - - 3 6 - 1 1 - 0 5

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 6 75.00 OK
Total Car 3 37.50 6 75.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 5 10.00 OK
Total TwoWheeler - - 5 10.00 OK
Other Parking - - - 82.60 OK
Total 50.00 190.10 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
PARKING FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.172 - 8 - - 0.000 OK
FOURTH FLOOR PLAN Fire Escape Staircase 0.900 1.200 0.250 0.250 0.200 0.178 16 8 - - 0.000 OK
TERRACE FLOOR PLAN Fire Escape Staircase - 1.200 - 0.250 - 0.000 16 0 - - 2.324 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 3.01 - - 1.26 - - 2.40 - - 0.00 OK
RWH - - 2.10 - - 1.58 - - 1.58 - - 0.00 OK
ENT.GATE - - 0.61 - - 0.12 - - 5.24 - - 0.00 OK
Entrance Lobby - 12.00 11.97 - - 2.40 - - 4.99 - - 0.00 OK
SHS - - 1.23 - - 1.25 - - 1.25 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:PARKING FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1- 3 FLOOR PLAN



No Room Found.

[-] Floor:FOURTH FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 352.87 OK
  Plot Width - 14.44 OK
  Plot Depth - 24.44 OK
  Access Width 6.10 6.10 OK
  Plot Frontage - 13.68 OK
  Coverage Area 211.72 194.60 OK
  FAR Area
Bldg. FAR Area : 705.50
Sanctioned FAR Area :0.00
705.74 705.50 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SARAIKELA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.5 mt., Rear 2.5mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
(4) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RWH
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SHS
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)