Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Plot Width |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Plot Depth |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
Access Width |
The minimum width of abutting road shall not be less than 6.1 mt. {As per Rule no. 61.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Plot Frontage |
The minimum size of plot for Affordable Housing Unit shall be 1500.0 sq.mt. {As per Chapter XI}
|
FAR Area |
(1)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
|
Consumed FAR |
(1)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2)
In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
DriveWay Rule |
(1)
For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
|
Margin Rule |
Affordable Housing having bldg ht. 10-12 mt.,no of floors as G+3, Plot Depth 45 mt. or above and Plot width 45 mt. or above, Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 4.0 mt. shall be provided on both side.
|
PWork to PWork Margin |
For Affordable Housing, Reqd Building to Building margin shall be 4.5 mt. or 1/4th of height of Building whichever is high {As per Rule No. 83.11}
|
Building Level |
Building Height |
For Affordable Housing, No height limitation shall be applicable {As per Chapter XI}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4)
The height of Plinth floor for Affordable Housing shall be Min. height 30 cm. from the surrounding ground level {As per Rule No. 83.18}
|
Parapet Height |
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Floor Number |
For Affordable Housing, No floor number limitation shall be applicable {As per Chapter XI}
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
-
(2)
No need to check distance from Building Sewage Treatment Plant
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4)
No need to check distance from Building RAIN WATER HARVESTING
(5)
No need to check distance from Building ENT.GATE
(6)
-
(7)
No need to check distance from Building SOLAR HEATING SYSTEM
(8)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(9)
No need to check distance from Building Generator Room
|
Building Level (Rooms) |