No Image Found   

Check List Report

Kodarma Nagar Panchayat

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 03-04-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityKODERMA NAGAR PANCHAYAT
Inward_NoKONPC/BP/0006/W05/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKodarma
Taluka25
Architect Details
Architect NameAnil Kumar Singh
License No.KONPC/ENG/0001/2017
Architect AddressAT Chotki Bagi, Koderma, PO/ Dist Koderma
Architect EmailIDanilkumarsingh70366@gmail.com
Architect Mobile No9470156651
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No689
NorthPlot No. - KODARMA CLUB
SouthRoad Width - 4.57 MTR WIDE MAIN ROAD Access Road
EastPlot No. - LAND OF SUNDAR NAGAR
WestRoad Width - 20.0 MTR WIDE MAIN ROAD Access Road
Owner's Details
NameMR AWADH KISHOR
AddressSUNDAR NAGAR KODARMA
Email IDanilkrsingh70366@gmail.com
Mobile No9534198039
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 485.41
2 Plot area as per Document by Applicant 485.41
3 Physical area measured at site 485.41
4 Area as per Site Visit (Site Visit Report) 485.41
5Area as per Drawing 485.08

Area of Plot Considered : 485.08

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 485.08
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 485.08
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 428.51
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 56.58
56.58
Balance Plot Area 428.51

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 242.54
Proposed Coverage Area ( 43.11 % ) 209.14
Total Prop. Coverage Area ( 43.11 % ) 209.14
Balance coverage area ( 6.89 % ) 33.40
FAR CHECK
Perm. FAR Area ( 2.000 ) 970.16
Total Perm. FAR area 970.16
Commercial FAR 386.83
Proposed FAR Area 399.94
Total Proposed FAR Area 399.94
Consumed FAR (Factor) 0.82
Balance FAR Area 570.22
BUA CHECK
Total Proposed BuiltUp Area 627.41


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 20 20.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 485.41 485.08
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 485.08 OK
Plot Width Mt. - - 16.86 OK
Plot Depth Mt. - - 28.77 OK
Access Width Mt. - - 20.00 OK
Plot Frontage Mt. - - 16.89 OK
Coverage Area Sq.Mt. - 242.54 209.14 OK
FAR Area Sq.Mt. - 970.16 399.94 OK
Consumed FAR Sq.Mt. - 2.00 0.82 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 24.25 56.58 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 56.58 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.87 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 13 OK
Car In Area Sq.Mt. - - 50.00 OK
Total Car In Area Sq.Mt. 25.00 - 131.00 OK
Parallel Car In Area Sq.Mt. - - 81.00 OK
Total Visitor Parking In Area Sq.Mt. - - 27.00 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 27.00 OK
TwoWheeler In Area Sq.Mt. - - 24.00 OK
Total TwoWheeler In Area Sq.Mt. 8.00 - 24.00 OK
ERiksha Stand Area In Area Sq.Mt. - - 81.00 OK
Other Parking In Area Sq.Mt. - - 117.75 OK
DriveWay A (MR AWADH KISHOR) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 4.10 OK
A-1 (MR AWADH KISHOR) Front Margin... 20.0 MTR WIDE MAIN ROAD Access Road Mt. 6.50 - 6.53 OK
Rear Margin Mt. 4.00 - 4.04 OK
Side1 Margin Mt. 2.50 - 2.51 OK
Side2 Margin Mt. 2.50 - 2.51 OK
A-1 (MR AWADH KISHOR) Basement Front Margin... 20.0 MTR WIDE MAIN ROAD Access Road Mt. 2.00 - 6.53 OK
Basement Rear Margin Mt. 2.00 - 4.04 OK
Basement Side1 Margin Mt. 2.00 - 2.51 OK
Basement Side2 Margin Mt. 2.00 - 2.51 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MR AWADH KISHOR) Height Mt. 36.53 6.37 OK
A (MR AWADH KISHOR) First Floor - Height Mt. 2.75 - 3.07 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Ground Floor - Height Mt. 2.75 - 3.07 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.86 OK
Basement Floor - Height Mt. 2.40 - 3.07 OK
Basement Floor - Clear Height Mt. 2.40 - 2.95 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.86 OK
A (MR AWADH KISHOR) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (MR AWADH KISHOR) Basement Floor - Height of Basement Floor above GL Mt. 0.90 1.50 1.43 OK
Basement Floor - Area Sq.Mt. - 209.14 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
A (MR AWADH KISHOR) Area Sq.Mt. - 209.14 OK
Status - OK
Total Area Sq.Mt. - 209.14 OK
A (MR AWADH KISHOR) No. of Basement Floor No. 1 1 OK
A (MR AWADH KISHOR) No. of Floors No. - 2 OK
No. of Tenements No. - 15 OK
A (MR AWADH KISHOR) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (MR AWADH KISHOR) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.15 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.15 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.15 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.99 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.15 OK
BASEMENT FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.750 1.227 OK
Staircase -3FL - Tread Width Mt. 0.225 0.268 OK
Staircase -3FL - Riser Height Mt. 0.200 - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.750 1.227 OK
Staircase -3FL - Tread Width Mt. 0.225 0.268 OK
Staircase -3FL - Riser Height Mt. 0.200 0.102 OK
Staircase -3FL - Riser No. On Flight No. - 7 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.750 1.227 OK
Staircase -3FL - Tread Width Mt. 0.225 0.268 OK
Staircase -3FL - Riser Height Mt. 0.200 0.102 OK
Staircase -3FL - Riser No. On Flight No. - 7 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.227 OK
Staircase -3FL - Tread Width Mt. - 0.268 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. 2.100 - 2.453 OK
Toilet Area Sq.Mt. - 5.00 1.80 OK
Width Mt. - - 1.33 OK
Depth Mt. - - 1.36 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.91 OK
Depth Mt. - - 0.99 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.80 OK
Width Mt. - - 1.33 OK
Depth Mt. - - 1.36 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.98 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 3.76 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 9.23 OK
Width Mt. - - 1.53 OK
Depth Mt. - - 6.02 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.46 OK
Width Mt. - - 1.53 OK
Depth Mt. - - 6.17 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.46 OK
Width Mt. - - 1.53 OK
Depth Mt. - - 5.52 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.68 OK
Width Mt. - - 1.21 OK
Depth Mt. - - 1.39 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 1.80 OK
Width Mt. - - 1.33 OK
Depth Mt. - - 1.36 OK
Height Mt. - - - OK
A (MR AWADH KISHOR) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 2.00 mt. long 1.50 mt. High 3.91 mt. Wide Natural Slope - Width Mt. - 2.00 OK
2.00 mt. long 1.50 mt. High 3.91 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
2.00 mt. long 1.50 mt. High 3.91 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (MR AWADH KISHOR) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Koderma Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Koderma Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 15-21 mt., Margin required in Front shall be 6.5 mt., Rear 4.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building Entrance Lobby
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)