No Image Found

Check List Report

Dhanbad Municipal Corporation

Version Number: 1.0.32
Version Date: 10/05/2018
Report Generated On: 01-02-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0006/W21/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageBisanpur
Taluka15
Architect Details
Architect NameKushjee Pandey
License No.DMC/ARC/0027/2017
Architect EmailIDkush@abhikalpadesign.com
Architect Mobile No9643660451
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No197,198
NorthPlot No. - Aruna devi
SouthPlot No. - Shaligram Mistry
EastRoad Width - 4.12
WestPlot No. - 200
Owner's Details
NameAjit Kumar
AddressS/o sri Ram Yatan Singh Babudih, P.o- B.Polytecnic, Dist-Dhanbad
Email IDhardikpatel10000@gmail.com
Mobile No9431125283
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 416.14
2 Plot area as per Document by Applicant 409.23
3 Physical area measured at site 409.23
4 Area as per Site Visit (Site Visit Report) 409.23
5Area as per Drawing 406.99

Area of Plot Considered : 406.99

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 406.99
Deduction from Gross Plot area
- Surrender Free of Cost 26.64
26.64
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 380.35
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 338.46
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 26.64
- Common Plot 41.89
68.53
Balance Plot Area 338.46

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 228.21
Proposed Coverage Area ( 52.25 % ) 198.75
Total Prop. Coverage Area ( 52.25 % ) 198.75
Balance coverage area ( 7.75 % ) 29.46
FAR CHECK
Perm. FAR Area ( 1.50 ) 610.48
Total Perm. FAR area 610.48
Residential FAR 596.26
Proposed FAR Area 596.26
Total Proposed FAR Area 596.26
Consumed FAR (Factor) 1.47
Balance FAR Area 14.22
BUA CHECK
Total Proposed BuiltUp Area 596.25


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 4.1 4.10
Proposed Road Width as per Master Plan 6.6 -
Road Widening Width 0 1.75
Plot size (as per measurement) 409.23 406.99


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 380.35 OK
Plot Width Mt. - - 14.12 OK
Plot Depth Mt. - - 26.95 OK
Access Width Mt. - - 4.10 OK
Plot Frontage Mt. - - 15.24 OK
Coverage Area Sq.Mt. - 228.21 198.75 OK
FAR Area Sq.Mt. - 610.48 596.26 OK
Consumed FAR Sq.Mt. - 1.50 1.47 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 38.03 41.89 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 41.89 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.37 OK
Tree Cover (Plantation) - Angle Degree - 85.13 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
A-1 (AJIT KUMAR) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 4.60 OK
Rear Margin Mt. 1.80 - 3.08 OK
Side1 Margin Mt. 0.90 - 1.15 OK
Side2 Margin Mt. 0.90 - 1.07 OK
A-1 (AJIT KUMAR) BldgLine for 4.10 MTR WIDE ROAD Access Road Mt. 1.70 6.35 OK
A-1 (AJIT KUMAR) ResvRoad Width Check for... 4.10 MTR WIDE ROAD Access Road Mt. 1.70 1.75 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (AJIT KUMAR) Height Mt. 10.00 9.00 OK
A (AJIT KUMAR) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Plinth - Height Mt. 0.45 - 0.78 OK
Plinth - Clear Height Mt. - - 0.78 OK
Plinth - Beam Clear Height Mt. - - 0.78 OK
A (AJIT KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.02 OK
A (AJIT KUMAR) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.046 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.046 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.046 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.046 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 3.000 OK
SUMP TANK Area Sq.Mt. - - 4.86 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 3.24 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.79 OK
Width Mt. - - 1.89 OK
Depth Mt. - - 2.54 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.25 OK
Width Mt. - - 0.37 OK
Depth Mt. - - 3.41 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 3.24 OK
Width Mt. - - 1.40 OK
Depth Mt. - - 2.31 OK
Height Mt. - - - OK
A (AJIT KUMAR) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road more than 100 and upto 250 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road more than 100 and upto 250 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)