No Image Found

Check List Report

Dhanbad Municipal Corporation

Version Number: 1.0.29
Version Date: 30/06/2018
Report Generated On: 08-10-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0079/W23/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKolakusma
Taluka15
Architect Details
Architect NameAjit Kumar
License No.DMC/ENG/0014/2016
Architect AddressFlat No. B2, Ground Floor, Prabha Appartment, Besides MADA, L.C.Road, Dhanbad-826001 (Jharkhand)
Architect EmailIDerajitkumardhn@gmail.com
Architect Mobile No9431124040
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD-(2259,2261,2260), NEW-(3152,3157,3159)
NorthPlot No. - 2259
SouthPlot No. - 2261,2263
EastPlot No. - 2260
WestRoad Width - 4.55
Owner's Details
NameSMT ASHA DEVI
AddressSASTRI NAGAR, MUNIDIH, QRT. NO. MM230
Email IDspsahscpa@gmail.com
Mobile No9939315362
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 336.52
2 Plot area as per Document by Applicant 329.92
3 Area as per Site Visit (Site Visit Report) 329.92
4Area as per Drawing 329.92

Area of Plot Considered : 329.92

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 329.92
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 329.92
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 301.06
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 28.86
28.86
Balance Plot Area 301.06

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 197.95
Proposed Coverage Area ( 54.83 % ) 180.88
Total Prop. Coverage Area ( 54.83 % ) 180.88
Balance coverage area ( 5.17 % ) 17.07
FAR CHECK
Perm. FAR Area ( 1.50 ) 494.88
Total Perm. FAR area 494.88
Residential FAR 361.76
Proposed FAR Area 361.76
Total Proposed FAR Area 361.76
Consumed FAR (Factor) 1.10
Balance FAR Area 133.12
BUA CHECK
Total Proposed BuiltUp Area 361.76


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.55 4.55
Proposed Road Width as per Master Plan 3.66 -
Road Widening Width 0 -
Plot size (as per measurement) 329.92 329.92


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 329.92 OK
Plot Width Sq.Mt. - - 15.24 OK
Plot Depth Sq.Mt. - - 21.64 OK
Access Width Sq.Mt. - - 4.55 OK
Plot Frontage Sq.Mt. - - 14.99 OK
Coverage Area Sq.Mt. - 197.95 180.88 OK
FAR Area Sq.Mt. - 494.88 361.76 OK
Consumed FAR Sq.Mt. - 1.50 1.10 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 16.50 28.86 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 28.86 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.05 OK
Tree Cover (Plantation) - Angle Degree - 89.98 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 10 OK
ASHA DEVI-1 (1) Front Margin... 4.55 mt. Wide MainRoad Mt. 3.00 - 3.52 OK
Rear Margin Mt. 1.80 - 3.04 OK
Side1 Margin Mt. 1.00 - 1.23 OK
Side2 Margin Mt. 1.00 - 1.21 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
ASHA DEVI (1) Height Mt. 10.00 6.00 OK
ASHA DEVI (1) First Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
ASHA DEVI (1) Terrace Floor - Height Mt. 1.00 1.20 1.05 OK
ASHA DEVI (1) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.068 OK
STAIRCASE - Tread Width Mt. 0.225 0.253 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.068 OK
STAIRCASE - Tread Width Mt. 0.225 0.253 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.068 OK
STAIRCASE - Tread Width Mt. - 0.253 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 3.000 OK
SUMP TANK Area Sq.Mt. - - 9.11 OK
Width Mt. - - 2.99 OK
Depth Mt. - - 3.05 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.42 OK
Width Mt. - - 1.84 OK
Depth Mt. - - 1.86 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.05 OK
Width Mt. - - 0.11 OK
Depth Mt. - - 9.79 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 3.09 OK
Width Mt. - - 1.98 OK
Depth Mt. - - 1.99 OK
Height Mt. - - - OK
ASHA DEVI (1) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)