No Image Found

Failed List Report

Dhanbad Municipal Corporation

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 30-08-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0108/W23/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKolakusma
Taluka15
Architect Details
Architect NameAshish kr singh
License No.DMC/ARC/0016/2017
Architect Address502 gokuldham tower kusum vihar koyla nagar
Architect EmailIDashish@creogenx.com
Architect Mobile No8789316969
Plot Details
Plot Use Residential
Plot SubUse Row House
PlotNearbyReligiousStructure NA
Plot/SubPlot No249 NEW (234)
NorthRoad Width - 6.09 M WIDE ROAD
SouthPlot No. - PART OF THIS PLOT
EastPlot No. - PART OF THIS PLOT
WestPlot No. - PART OF THIS PLOT
Owner's Details
NameSMT BHARTI DEVI
AddressBLOCK NO 14 M.O.C.P. COLONY , P.S - TISRA , DHANBAD
Email IDabhisheksinghunik@gmail.com
Mobile No7654165006
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 221.48
2 Plot area as per Document by Applicant 221.48
3 Physical area measured at site 191.76
4 Area as per Site Visit (Site Visit Report) 191.76
5Area as per Drawing 191.74

Area of Plot Considered : 191.74

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Row House
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 191.74
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 191.74
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 145.28
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 46.47
46.47
Balance Plot Area 145.28

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 134.22
Proposed Coverage Area ( 60.39 % ) 115.79
Total Prop. Coverage Area ( 60.39 % ) 115.79
Balance coverage area ( 9.61 % ) 18.43
FAR CHECK
Perm. FAR Area ( 1.80 ) 345.13
Total Perm. FAR area 345.13
Residential FAR 231.59
Proposed FAR Area 231.59
Total Proposed FAR Area 231.59
Consumed FAR (Factor) 1.21
Balance FAR Area 113.54
BUA CHECK
Total Proposed BuiltUp Area 231.58


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.09 6.09
Proposed Road Width as per Master Plan 3.66 -
Road Widening Width 0 -
Plot size (as per measurement) 191.76 191.74





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Plot Width The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Plot Depth The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)