-
No Image Found

Failed List Report

Dhanbad Municipal Corporation

Version Number: 1.0.33
Version Date: 27/02/2019
Report Generated On: 12-03-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0244/W23/2018
Application TypeGeneral Proposal
Project TypeGroup Development Scheme
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDhanbad
Taluka15
Architect Details
Architect NameAVINASH KUMAR KESHRI
License No.DMC/ARC/0015/2017
Architect AddressC/O- DASHARATH AMBUJ STREET- PANCHWATIPURAM, BARIATU, RANCHI
Architect EmailIDavi2k5@gmail.com
Architect Mobile No8826301177
Plot Details
Plot Use Residential
Plot SubUse Group Housing
PlotNearbyReligiousStructure NA
Plot/SubPlot No247,252
NorthPlot No. - other plot
SouthRoad Width - 7.5
EastPlot No. - other plot
WestRoad Width - 6.1
Owner's Details
NameDEVI SHARAN SINHA GYAN RANJAN SINHA NAYAN RANJAN SINHA DILIP KUMAR SINHA SHAILENDRA NATH SINHA ADITYA NARAYAN PRASAD KULDIP PRASAD SINGH UMA SHANKER PRASAD SUNAYNA GUPTA ARBIND KUMAR SATYARTHY ABHISHEK KUMAR
AddressNIRMALA KUNJ, FLAT NO- 102, VEER KUNWAR SINGH COLONY, KARMIK NAGAR,DHANBAD
Email IDinfo@nirmalanand.in
Mobile No9431182089
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 4453.53
2 Plot area as per Document by Applicant 4453.53
3 Physical area measured at site 3688.79
4 Area as per Site Visit (Site Visit Report) 3688.79
5Area as per Drawing 3687.51

Area of Plot Considered : 3687.51

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Group Housing
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 3687.51
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3687.51
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3316.17
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 371.34
371.34
Balance Plot Area 3316.17

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 35.00 % ) 1290.63
Proposed Coverage Area ( 34.86 % ) 1285.29
Total Prop. Coverage Area ( 34.86 % ) 1285.29
Balance coverage area ( 0.14 % ) 5.34
FAR CHECK
Perm. FAR Area ( 3.50 ) 12906.29
Total Perm. FAR area 12906.29
Residential FAR 11681.47
Proposed FAR Area 11780.81
Total Proposed FAR Area 11780.81
Consumed FAR (Factor) 3.19
Balance FAR Area 1125.48
BUA CHECK
Total Proposed BuiltUp Area 16039.75


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 7.5 7.50
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 3688.79 3687.51
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Group Housing shall be 3000.0 sq.mt.{As per Chapter VI}
Plot Width The minimum size of plot for Group Housing shall be 3000.0 sq.mt.{As per Chapter VI}
Plot Depth The minimum size of plot for Group Housing shall be 3000.0 sq.mt.{As per Chapter VI}
Access Width The minimum width of abutting road for Group Housing shall be 6.10 mt.{As per Chapter VI}
Plot Frontage The minimum size of plot for Group Housing shall be 3000.0 sq.mt.{As per Chapter VI}
FAR Area (1) In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2) In Group Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Chapter VI}
Consumed FAR (1) In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2) In Group Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Chapter VI}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule (1) In case of buildings of more than 30m height, for every increase in height of 6.7 m. or fraction thereof or addition of two floor, 1m. in the front set back and 0.75 m. in the sides and rear setbacks shall be added {As per Rule No. 37 Table 14 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 45 mt. or above, Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 3.66 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For Group Housing, No height limitation shall be applicable except in areas near protected monuments and airport, etc {As per Chapter VI}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For Group Housing, No floor number limitation shall be applicable {As per Chapter XI}
Balcony (1) Projected balcony may be allowed on first floor subject to condition that the side and rear setback of the Building is more than 4.5 mt. and 4.5m. clear driveway is available for Fire movement. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, above G+4 floors or if the number of flats is 16 or more, Mini. 1 Lift shall be required For every 16 flats or part thereof. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is more then 40, two ramp of minimum of 3.30m width if it is strait and 3.6 width if it is curved at any point, or one ramp of minimum 5.4 m width and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. For height more than 2.4m,slope shall not exceed 1:20. {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is more then 500sq.mt.,atleast two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved or one ramp of minimum 5.4m width shall be provided
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) -
(6) No need to check distance from Building Sewage Treatment Plant
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building RAIN WATER HARVESTING
(9) -
(10) No need to check distance from Building Fire Hydrants
(11) No need to check distance from Building ENT.GATE
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)