No Image Found   

Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.50  
Version Date: 16/10/2020 
Report Generated On: 05-11-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0207/W22/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhelatand
Taluka15
Architect Details
Architect NamePARTHA - PAL
License No.DMC/ENG/0021/2016
Architect AddressLIG-283, HOUSING COLONY, DHANBAD
Architect EmailIDpalpartha078@gmail.com
Architect Mobile No9835129422
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No716(old), 820(new)
NorthPlot No. - PLOT NO 716
SouthPlot No. - YAMUNA PANDEY
EastRoad Width - 4.87
WestPlot No. - RANJIT SINGH
Owner's Details
NameLALITA KUMARI.
AddressSASANBERIA, P.S NIRSA ,DHANBAD
Email IDPalpartha078@gmail.com
Mobile No6200868825
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 167.13
2 Plot area as per Document by Applicant 167.13
3 Physical area measured at site 163.17
4 Area as per Site Visit (Site Visit Report) 163.17
5Area as per Drawing 163.17

Area of Plot Considered : 163.17

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 163.17
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 163.17
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 136.54
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 26.63
26.63
Balance Plot Area 136.54

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 114.22
Proposed Coverage Area ( 57.49 % ) 93.81
Total Prop. Coverage Area ( 57.49 % ) 93.81
Balance coverage area ( 12.51 % ) 20.41
FAR CHECK
Perm. FAR Area ( 1.50 ) 244.76
Total Perm. FAR area 244.76
Residential FAR 291.64
Proposed FAR Area 291.64
Total Proposed FAR Area 291.64
Consumed FAR (Factor) 1.79
Balance FAR Area 0.00
Total Paid Proposed FAR Area 46.88
BUA CHECK
Total Proposed BuiltUp Area 291.63


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 0 -
Plot size (as per measurement) 163.17 163.17
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 8.16 26.63 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 26.63 0.00 0.00 - 3.02 - 89.06 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 5 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
AA (AA) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
AA (AA) 9.95 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
AA (AA) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
AA (AA) Terrace Floor 1.00 1.20 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
AA (AA) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
114.22 93.81 OK
70% 57.49%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  AA-1 (AA) - 93.81
  Total Prop. Coverage Area - 93.81
  Total Coverage Area 114.22 93.81

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
AA (AA) 1 291.63 291.63 291.63 291.63 01
Grand Total : 1 291.63 291.63 291.63 291.63 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
AA (AA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 93.81 93.81 93.81 93.81
First Floor 98.91 98.91 98.91 98.91
Second Floor 98.91 98.91 98.91 98.91
Terrace Floor 0.00 0.00 0.00 0.00
Total : 291.63 291.63 291.63 291.63


[-] UnitBUA Table for Building :AA (AA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT AA FLAT 291.64 291.40 7 1
FIRST FLOOR PLAN SPLIT AA FLAT 0.00 0.00 9 0
SECOND FLOOR PLAN SPLIT AA FLAT 0.00 0.00 9 0
Total: - - 291.64 291.40 25 1


[-] Building :AA (AA)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 93.81 93.81 93.81 93.81 01
First Floor 98.91 98.91 98.91 98.91 00
Second Floor 98.91 98.91 98.91 98.91 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 291.63 291.63 291.63 291.63 01
Total Number of Same Buildings : 1
Total : 291.63 291.63 291.63 291.63 01
[-] Table 4c-2

  FAR Area
Building FAR Area:291.64
Existing FAR Area :0.00
Perm.
244.76
Prop.
291.64
Status
Failed




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
AA-1 (AA) 4.57 mt. Wide MainRoad 2.50 3.10 1.50 2.10 0.90 0.90 - 0.45 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: AA (AA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :AA (AA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.900 0.250 0.250 0.200 0.150 - 3 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 0.900 0.250 0.250 0.200 0.150 - 3 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.900 0.250 0.250 0.200 0.150 - 3 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 7.65 - - 2.06 - - 3.72 - - 0.00 OK
RAIN WATER HARVESTING - - 2.25 - - 1.50 - - 1.50 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:AA (AA)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 163.17 OK
  Plot Width - 9.00 OK
  Plot Depth - 18.13 OK
  Access Width - 4.57 OK
  Plot Frontage - 9.00 OK
  Coverage Area 114.22 93.81 OK
  FAR Area
Bldg. FAR Area : 291.64
Sanctioned FAR Area :0.00
244.76 291.64 Failed





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)