No Image Found   

Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 25-02-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0029/W22/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKolakusma
Taluka15
Architect Details
Architect NameRAJEEV RANJAN SINGH
License No.DMC/ENG/0032/2017
Architect AddressRADHA KRISHNA NAGAR, SUBA SINGH MAINSON, NEAR BINOD BIHARI CHOWK, OMKAR CITY
Architect EmailIDrajeev3003sai@gmail.com
Architect Mobile No9835815638
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No400(P), NEW-65
NorthRoad Width - 45
SouthPlot No. - 401,406 & VILLAGE ROAD
EastPlot No. - 416
WestPlot No. - 400 (P), AND RELIANCE OFFICE BUILDING
Owner's Details
NameSRI SANTOSH KUMAR SINGH
AddressSHANTI COLONY, SARAIDHELA P.S- SARAIDHELA DIST- DHANBAD
Email IDsantoshkumarsingh72.ss@gmail.com
Mobile No9905161031
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1457.39
2 Plot area as per Document by Applicant 1457.36
3 Physical area measured at site 1457.36
4 Area as per Site Visit (Site Visit Report) 1457.35
5Area as per Drawing 1456.93

Area of Plot Considered : 1456.93

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1456.93
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1456.93
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1063.50
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 393.43
393.43
Balance Plot Area 1063.50

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 728.47
Proposed Coverage Area ( 42.21 % ) 614.97
Total Prop. Coverage Area ( 42.21 % ) 614.97
Balance coverage area ( 7.79 % ) 113.50
FAR CHECK
Perm. FAR Area ( 2.50 ) 3642.33
Total Perm. FAR area 3642.33
Residential FAR 275.46
Commercial FAR 2748.33
Proposed FAR Area 3032.96
Total Proposed FAR Area 3032.96
Consumed FAR (Factor) 2.08
Balance FAR Area 609.37
BUA CHECK
Total Proposed BuiltUp Area 3673.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 45 45.00
Proposed Road Width as per Master Plan 3.66 -
Road Widening Width 0 -
Plot size (as per measurement) 1457.35 1456.93
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 145.69 393.43 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 393.43 0.00 0.00 - 20.41 - 74.75 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 26 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI SANTOSH KUMAR SINGH) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Status
Perm Prop
A (SRI SANTOSH KUMAR SINGH) 82.99 15.24 15.24 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI SANTOSH KUMAR SINGH) Fourth Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.64 OK
Third Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.64 OK
Second Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.64 OK
First Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.64 OK
Ground Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.64 OK
Basement Floor 2.40 - 2.74 2.40 - 2.64 2.10 - 2.34 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI SANTOSH KUMAR SINGH) Terrace Floor 1.00 1.20 1.07 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (SRI SANTOSH KUMAR SINGH) Basement Floor - 2.74 - 615.92 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (SRI SANTOSH KUMAR SINGH) - 615.92
Total - 615.92 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (SRI SANTOSH KUMAR SINGH)   45 mt. Wide MainRoad 3.00 15.49 3.00 5.55 2.50 3.06 2.50 3.33 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI SANTOSH KUMAR SINGH) - 5 - 6 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (SRI SANTOSH KUMAR SINGH) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
728.47 614.97 OK
50% 42.21%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRI SANTOSH KUMAR SINGH) - 614.97
  Total Prop. Coverage Area - 614.97
  Total Coverage Area 728.47 614.97

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Parking Resi. Commercial Stair
A (SRI SANTOSH KUMAR SINGH) 1 3695.53 22.29 3673.24 41.90 598.37 275.46 2748.33 9.17 3032.97 3032.97 06
Grand Total : 1 3695.53 22.29 3673.24 41.90 598.37 275.46 2748.33 9.17 3032.97 3032.97 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI SANTOSH KUMAR SINGH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 615.92 9.17 615.92 9.17
Ground Floor 614.97 614.97 614.97 614.97
First Floor 615.92 607.54 615.92 607.54
Second Floor 608.81 600.43 608.81 600.43
Third Floor 608.81 600.43 608.81 600.43
Fourth Floor 608.81 600.43 608.81 600.43
Terrace Floor 0.00 0.00 0.00 0.00
Total : 3673.24 3032.97 3673.24 3032.97


[-] UnitBUA Table for Building :A (SRI SANTOSH KUMAR SINGH)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN Banquet OTHER 606.58 606.38 15 1
FIRST FLOOR PLAN Resturant OTHER 607.54 607.30 11 1
TYPICAL - 2& 3 FLOOR PLAN HOTEL OFFICE 600.43 600.14 34 2
FOURTH FLOOR PLAN A FLAT 275.46 275.39 16 2
HOTEL OFFICE 324.97 324.68 17
Total: - - 3015.40 3014.03 127 6


[-] Building :A (SRI SANTOSH KUMAR SINGH)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Parking Resi. Commercial Stair
Basement Floor 615.92 0.00 615.92 8.38 598.37 0.00 0.00 9.17 9.17 9.17 00
Ground Floor 615.93 0.96 614.97 0.00 0.00 0.00 614.97 0.00 614.97 614.97 01
First Floor 615.92 0.00 615.92 8.38 0.00 0.00 607.54 0.00 607.54 607.54 01
Second Floor 615.92 7.11 608.81 8.38 0.00 0.00 600.43 0.00 600.43 600.43 01
Third Floor 615.92 7.11 608.81 8.38 0.00 0.00 600.43 0.00 600.43 600.43 01
Fourth Floor 615.92 7.11 608.81 8.38 0.00 275.46 324.97 0.00 600.43 600.43 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 3695.53 22.29 3673.24 41.90 598.37 275.46 2748.33 9.17 3032.97 3032.97 06
Total Number of Same Buildings : 1
Total : 3695.53 22.29 3673.24 41.90 598.37 275.46 2748.33 9.17 3032.97 3032.97 06
[-] Table 4c-2

  FAR Area
Building FAR Area:3032.96
Existing FAR Area :0.00
Perm.
3642.33
Prop.
3032.96
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI SANTOSH KUMAR SINGH) 45 mt. Wide MainRoad 6.00 15.49 5.00 5.55 2.50 3.06 2.50 3.34 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (SRI SANTOSH KUMAR SINGH) 15.24 1 2 OK

[-] Lift Check Table

[-] For Building :A (SRI SANTOSH KUMAR SINGH)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.70 1.90 1.98 OK
GROUND FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.70 1.90 1.98 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.98 OK
FIRST FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.70 1.90 1.98 OK
TYPICAL - 2& 3 FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.70 1.90 1.98 OK
FOURTH FLOOR PLAN Lift 1.70 1.70 1.90 1.98 OK
Lift 1.70 1.83 1.90 2.74 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SRI SANTOSH KUMAR SINGH) Commercial Shop > 0 50 2640.27 1 36 - - - - - - -
> 0 50 2640.27 - - - - - - 1 110 -
Residential Residential Bldg/Apartment 0 - 140 1 - 1 - - - - - - - -
> 140 1.5 - 1 1.5 - - - - - - -
> 0 1 1.00 - - - - - - 1 1 -
> 0 1 1.00 - - - 1 1 - - - -
Total : - - - - 38 25 - 1 1 - 111 44

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 25 312.50 OK
Total Car 38 475.00 25 312.50 FAILED
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 44 88.00 OK
Total TwoWheeler 111 222.00 44 88.00 FAILED
Other Parking - - - 323.37 OK
Total 709.50 836.87 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI SANTOSH KUMAR SINGH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN Internal Staircase - 1.219 - 0.000 - 0.254 14 12 - - 0.000 OK
Internal Staircase - 1.524 - 0.254 - 0.145 14 11 - - 0.000 OK
FIRST FLOOR PLAN Internal Staircase - 1.219 - 0.000 - 0.254 14 12 - - 0.000 OK
Internal Staircase - 1.524 - 0.254 - 0.145 14 11 - - 0.000 OK
TYPICAL - 2& 3 FLOOR PLAN Internal Staircase - 1.219 - 0.000 - 0.254 14 12 - - 0.000 OK
Internal Staircase - 1.524 - 0.254 - 0.145 14 11 - - 0.000 OK
FOURTH FLOOR PLAN Internal Staircase - 1.219 - 0.000 - 0.254 14 12 - - 0.000 OK
Internal Staircase - 1.524 - 0.254 - 0.145 14 11 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
15.00 mt. long 1.50 mt. High 2.00 mt. Wide Natural Slope - 3.05 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SRI SANTOSH KUMAR SINGH) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 5.02 - - 1.69 - - 2.98 - - 0.00 OK
RAIN WATER HARVESTING - - 2.14 - - 1.41 - - 1.51 - - 0.00 OK
ENT.GATE - - 0.97 - - 0.41 - - 2.37 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.46 - - 0.46 - - 3.16 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI SANTOSH KUMAR SINGH) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRI SANTOSH KUMAR SINGH)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 2& 3 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FOURTH FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1456.93 OK
  Plot Width - 24.57 OK
  Plot Depth - 59.30 OK
  Access Width 6.10 45.00 OK
  Plot Frontage - 24.25 OK
  Coverage Area 728.47 614.97 OK
  FAR Area
Bldg. FAR Area : 3032.96
Sanctioned FAR Area :0.00
3642.33 3032.96 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 21-27 mt., Margin required in Front shall be 6.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)