-
No Image Found   

Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 16-08-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0257/W23/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKolakusma
Taluka15
Architect Details
Architect NameAMIT KUMAR
License No.DMC/ENG/0012/2021
Architect AddressDESIGN VIEW, GROUND FLOOR, BHAWANI APARTMENT, PARK MARKET HIRAPUR
Architect EmailIDamitkumarraj704@gmail.com
Architect Mobile No8409688888
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD - 3462, 3494, NEW - 4211, 4282
NorthPlot No. - DEBADUTTA MOHANTY
SouthPlot No. - PRADIP KUMAR
EastRoad Width - 7.62
WestPlot No. - ASHISH KUMAR SINGH
Owner's Details
NamePIYUSH KUMAR SENGAR, SMITA PRIYADARSHINI
AddressHIRAK ROAD, KOLAKUSHMA, SARAIDHELA, DHANBAD
Email IDamitkumarraj704@gmail.com
Mobile No9155810075
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 175.69
2 Plot area as per Document by Applicant 175.59
3 Physical area measured at site 175.59
4 Area as per Site Visit (Site Visit Report) 175.65
5Area as per Drawing 175.59

Area of Plot Considered : 175.59

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 175.59
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 175.59
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 156.77
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 18.81
18.81
Balance Plot Area 156.77

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 122.91
Proposed Coverage Area ( 55.21 % ) 96.94
Total Prop. Coverage Area ( 55.21 % ) 96.94
Balance coverage area ( 14.79 % ) 25.97
FAR CHECK
Perm. FAR Area ( 2.50 ) 438.97
Total Perm. FAR area 438.97
Residential FAR 205.73
Proposed FAR Area 205.73
Total Proposed FAR Area 205.73
Consumed FAR (Factor) 1.17
Balance FAR Area 233.24
BUA CHECK
Total Proposed BuiltUp Area 223.52


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 6.7 7.62
Proposed Road Width as per Master Plan 6.7 -
Road Widening Width 0 -
Plot size (as per measurement) 175.65 175.59

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 8.78 18.81 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
RECREATION - 18.81 7.62 M WIDE ROAD OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A1 (A1) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A1 (A1) 13.44 6.10 6.10 6.10 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (A1) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.90 OK
Ground Floor 2.75 - 3.10 2.75 - 3.00 2.40 - 3.00 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A1 (A1) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A1 (A1) G + 5 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
122.91 96.94 OK
70% 55.21%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A1-1 (A1) - 96.94
  Total Prop. Coverage Area - 96.94
  Total Coverage Area 122.91 96.94

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Balcony Archi.Proj. Resi.
A1 (A1) 1 223.52 2.97 14.82 205.73 205.73 205.73 01
Grand Total : 1 223.52 2.97 14.82 205.73 205.73 205.73 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A1 (A1)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 111.76 96.94 111.76 96.94
First Floor 111.76 108.79 111.76 108.79
Terrace Floor 0.00 0.00 0.00 0.00
Total : 223.52 205.73 223.52 205.73


[-] UnitBUA Table for Building :A1 (A1)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT 1 FLAT 208.71 202.32 6 1
FIRST FLOOR PLAN SPLIT 1 FLAT 0.00 0.00 6 0
Total: - - 208.71 202.32 12 1


[-] Building :A1 (A1)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Balcony Archi.Proj. Resi.
Ground Floor 111.76 0.00 14.82 96.94 96.94 96.94 01
First Floor 111.76 2.97 0.00 108.79 108.79 108.79 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 223.52 2.97 14.82 205.73 205.73 205.73 01
Total Number of Same Buildings : 1
Total : 223.52 2.97 14.82 205.73 205.73 205.73 01
[-] Table 4c-2

  FAR Area
Building FAR Area:205.73
Existing FAR Area :0.00
Perm.
438.97
Prop.
205.73
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A1-1 (A1) 7.62 M WIDE ROAD 2.00 2.01 1.50 1.52 0.90 0.92 0.90 0.92 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A1 (A1)
Floor Name Balcony Name Width Status
Perm Prop
FIRST FLOOR PLAN BALCONY 0.90 1.35 Failed



For PWork At Layout : 

No Balcony Found.

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A1 (A1)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A1 (A1)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.750 0.991 0.225 0.254 0.200 0.129 - 6 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.750 0.991 0.225 0.254 0.200 0.125 - 6 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 0.991 - 0.254 - 0.000 - 0 2.100 - 2.500 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A1 (A1)
Floor Name Arch Proj Name Width Status
Perm Prop
GROUND FLOOR PLAN PORTICO - 3.35 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 4.67 - - 1.44 - - 3.26 - - 0.00 OK
RAIN WATER HARVESTING - - 3.11 - - 1.19 - - 2.61 - - 0.00 OK
SOLAR HEATING SYSTEM - - 3.39 - - 1.49 - - 2.28 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A1 (A1) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A1 (A1)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 175.59 OK
  Plot Width - 12.80 OK
  Plot Depth - 13.72 OK
  Access Width - 7.62 OK
  Plot Frontage - 12.80 OK
  Coverage Area 122.91 96.94 OK
  FAR Area
Bldg. FAR Area : 205.73
Sanctioned FAR Area :0.00
438.97 205.73 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection No need to check
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)