-
No Image Found   

Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 30-05-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0112/W23/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKolakusma
Taluka15
Architect Details
Architect NameASHOK KUMAR
License No.DMC/ENG/0011/2017
Architect AddressASTHA TRADE CENTER BEKAR BANDH BDANBAD
Architect EmailIDhdassociates02@gmail.com
Architect Mobile No7903779603
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD 1942, NEW 2550/4971
NorthPlot No. - PART OF PLOT NO 1942
SouthSurvey No. - BCCL BOUNDARY
EastPlot No. - PART OF PLOT NO 1942
WestPlot No. - purchaser'S NIZ.
Owner's Details
NameSRI KAUSHAL KISHOR SINGH
AddressKUSHUM BIHAR PHASE 2 DHANBAD JHARJHAND
Email IDkaushal_2023@yahoo.com
Mobile No9470596347
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 340.00
2 Plot area as per Document by Applicant 340.00
3 Physical area measured at site 340.00
4 Area as per Site Visit (Site Visit Report) 339.90
5Area as per Drawing 339.07

Area of Plot Considered : 339.07

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotRESIDENTIAL
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 339.07
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 339.07
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 320.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 18.45
18.45
Balance Plot Area 320.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 203.44
Proposed Coverage Area ( 42.37 % ) 143.67
Total Prop. Coverage Area ( 42.37 % ) 143.67
Balance coverage area ( 17.63 % ) 59.77
FAR CHECK
Perm. FAR Area ( 1.80 ) 610.33
Total Perm. FAR area 610.33
Residential FAR 423.19
Proposed FAR Area 423.19
Total Proposed FAR Area 423.19
Consumed FAR (Factor) 1.25
Balance FAR Area 187.14
BUA CHECK
Total Proposed BuiltUp Area 431.03


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.8 4.87
Proposed Road Width as per Master Plan 4.8 -
Road Widening Width 0 -
Plot size (as per measurement) 339.9 339.07

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 16.95 18.45 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 18.45 0.00 0.00 - 2.36 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (KK) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (KK) 10.00 9.13 9.13 9.13 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (KK) Second Floor 2.75 - 3.04 2.75 - 2.94 2.40 - 2.74 OK
First Floor 2.75 - 3.04 2.75 - 2.94 2.40 - 2.74 OK
Ground Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (KK) Terrace Floor - - 1.01 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (KK) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
203.44 143.67 OK
60% 42.37%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (KK) - 143.67
  Total Prop. Coverage Area - 143.67
  Total Coverage Area 203.44 143.67

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Resi.
A (KK) 1 431.03 7.84 423.19 423.19 423.19 01
Grand Total : 1 431.03 7.84 423.19 423.19 423.19 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (KK)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 143.67 143.67 143.67 143.67
First Floor 143.68 139.76 143.68 139.76
Second Floor 143.68 139.76 143.68 139.76
Terrace Floor 0.00 0.00 0.00 0.00
Total : 431.03 423.19 431.03 423.19


[-] UnitBUA Table for Building :A (KK)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT 1 FLAT 409.49 409.42 14 1
TYPICAL - 1, 2 FLOOR PLAN SPLIT 1 FLAT 0.00 0.00 14 0
Total: - - 409.49 409.42 42 1


[-] Building :A (KK)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Resi.
Ground Floor 143.67 0.00 143.67 143.67 143.67 01
First Floor 143.68 3.92 139.76 139.76 139.76 00
Second Floor 143.68 3.92 139.76 139.76 139.76 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 431.03 7.84 423.19 423.19 423.19 01
Total Number of Same Buildings : 1
Total : 431.03 7.84 423.19 423.19 423.19 01
[-] Table 4c-2

  FAR Area
Building FAR Area:423.19
Existing FAR Area :0.00
Perm.
610.33
Prop.
423.19
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (KK) 4.87 MT. WD. ROAD 3.00 5.55 1.80 4.34 0.90 1.67 0.90 1.72 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (KK) 9.13 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (KK)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.88 1.90 2.08 OK
GROUND FLOOR PLAN Lift Lobby 1.70 1.26 1.90 2.59 Failed
Lift 1.70 1.88 1.90 2.08 OK
TYPICAL - 1, 2 FLOOR PLAN Lift Lobby 1.70 1.26 1.90 2.59 Failed
Lift 1.70 1.88 1.90 2.08 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (KK)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (KK)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.279 - 0.000 - 0 - - 2.111 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.279 0.200 0.152 - 10 - - 0.000 OK
TYPICAL - 1, 2 FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.279 0.200 0.152 - 10 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 4.76 - - 1.40 - - 3.40 - - 0.00 OK
RAIN WATER HARVESTING - - 2.38 - - 1.40 - - 1.70 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.09 - - 1.15 - - 1.82 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (KK) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (KK)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT 1 TOILET 1.20X2.21 2.80 2.65 1.20 1.20 1.20 2.21 0.30 0.92 Failed

[-] Floor:TYPICAL - 1, 2 FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT 1 TOILET 1.20X2.21 2.80 2.65 1.20 1.20 1.20 2.21 0.30 0.92 Failed


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 339.07 OK
  Plot Width - 13.11 OK
  Plot Depth - 25.86 OK
  Access Width - 4.87 OK
  Plot Frontage - 17.88 OK
  Coverage Area 203.44 143.67 OK
  FAR Area
Bldg. FAR Area : 423.19
Sanctioned FAR Area :0.00
610.33 423.19 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) Lift lobby should be not free from FAR
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(6) The area of lift well shall not be counted for F.A.R calculation)
(7) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)