No Image Found   

Check List Report

Dhanbad Municipal Corporation

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 06-02-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0401/W20/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBisanpur
Taluka15
Architect Details
Architect NameRAJEEV RANJAN SINGH
License No.DMC/ENG/0032/2017
Architect AddressRADHA KRISHNAN NAGAR, SUBA SINGH MANSION,NAWADIH NEAR BINOD BIHARI CHOWK
Architect EmailIDrajeev7sai@gmail.com
Architect Mobile No6202360891
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD-293(P) NEW-567
NorthRoad Width - 3.65
SouthPlot No. - LAND OF BAMESHWAR SHARMA
EastRoad Width - 3.65
WestPlot No. - VENDOR'S OWN LAND
Owner's Details
NameRAMANUJ KUMAR SHARMA
AddressHOUSING COLONY , DHANBAD
Email IDsksanjay32@gmai.com
Mobile No9835554492
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 283.38
2 Plot area as per Document by Applicant 283.25
3 Physical area measured at site 283.25
4 Area as per Site Visit (Site Visit Report) 283.29
5Area as per Drawing 282.78

Area of Plot Considered : 282.78

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 282.78
Deduction from Gross Plot area
- Surrender Free of Cost 24.61
24.61
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 258.17
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 238.67
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 24.61
- Common Plot 19.50
44.11
Balance Plot Area 238.67

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 154.90
Proposed Coverage Area ( 48.07 % ) 124.11
Total Prop. Coverage Area ( 48.07 % ) 124.11
Balance coverage area ( 11.93 % ) 30.79
FAR CHECK
Perm. FAR Area ( 1.500 ) 424.17
Total Perm. FAR area 424.17
Residential FAR 376.82
Proposed FAR Area 376.82
Total Proposed FAR Area 376.82
Consumed FAR (Factor) 1.33
Balance FAR Area 47.35
BUA CHECK
Total Proposed BuiltUp Area 381.33


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.81 3.81
Proposed Road Width as per Master Plan 5.1 -
Road Widening Width 0.645 0.65
Plot size (as per measurement) 283.29 282.78
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 258.17 OK
Plot Width Mt. - - 13.06 OK
Plot Depth Mt. - - 19.76 OK
Access Width Mt. - - 3.81 OK
Plot Frontage Mt. - - 13.83 OK
Coverage Area Sq.Mt. - 154.90 124.11 OK
FAR Area Sq.Mt. - 424.17 376.82 OK
Consumed FAR Sq.Mt. - 1.50 1.33 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 12.91 19.50 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 19.50 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.53 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
A-1 (A) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.50 - 6.55 OK
Rear Margin Mt. 1.50 - 1.64 OK
Side1 Margin Mt. 0.90 - 0.91 OK
Side2 Margin Mt. 0.90 - 0.90 OK
A-1 (A) BldgLine for 3.81 m wide road Mt. 0.64 7.20 OK
A-1 (A) ResvRoad Width Check for... 3.81 m wide road Mt. 0.64 0.65 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (A) Height Mt. 10.00 9.75 OK
A (A) Second Floor - Height Mt. 2.75 - 3.25 OK
Second Floor - Clear Height Mt. 2.75 - 3.15 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.96 OK
First Floor - Height Mt. 2.75 - 3.25 OK
First Floor - Clear Height Mt. 2.75 - 3.15 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.96 OK
Ground Floor - Height Mt. 2.75 - 3.25 OK
Ground Floor - Clear Height Mt. 2.75 - 3.15 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.96 OK
A (A) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (A) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
A (A) TYPICAL - 1, 2 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.92 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.148 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.148 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.016 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.591 OK
SUMP TANK Area Sq.Mt. - - 2.91 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 1.91 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.26 OK
Width Mt. - - 1.10 OK
Depth Mt. - - 1.15 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.61 OK
Width Mt. - - 1.18 OK
Depth Mt. - - 1.37 OK
Height Mt. - - - OK
A (A) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)