General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0074/W22/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhelatand
Taluka15
Architect Details
Architect NameAMRESH KUMAR BHARTI
License No.DMC/ENG/0022/2016
Architect AddressS/O RAM DARAS BHARTI, OPP. BHARTI PUBLIC SCHOOL, BHAWTARNI PATH, MANAITAND
Architect EmailIDamresh4249@gmail.com
Architect Mobile No9472763846
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No639, 640(OLD), 533(NEW)
NorthPlot No. - PART OF THIS PLOT
SouthRoad Width - 4.87 WIDE ROAD
EastPlot No. - SHAILENDRA SINGH
WestRoad Width - 7.62 WIDE ROAD
Owner's Details
NameSMT LILA DEVI
AddressJHARIA PARA CHIRKUNDA, P.S.- CHIRKUNDA, DIST.- DHANBAD.
Email IDchandrakets332@gmail.com
Mobile No9835569303
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 200.39
2 Plot area as per Document by Applicant 198.77
3 Physical area measured at site 198.77
4 Area as per Site Visit (Site Visit Report) 198.77
5Area as per Drawing 198.67

Area of Plot Considered : 198.67

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 198.67
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 198.67
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 177.68
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 20.99
20.99
Balance Plot Area 177.68

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 139.07
Proposed Coverage Area ( 54.72 % ) 108.72
Total Prop. Coverage Area ( 54.72 % ) 108.72
Balance coverage area ( 15.28 % ) 30.35
FAR CHECK
Perm. FAR Area ( 2.500 ) 496.67
Total Perm. FAR area 496.67
Residential FAR 326.16
Proposed FAR Area 326.16
Total Proposed FAR Area 326.16
Consumed FAR (Factor) 1.64
Balance FAR Area 170.51
BUA CHECK
Total Proposed BuiltUp Area 356.64


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 7.62 7.62
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 198.77 198.67
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 198.67 OK
Plot Width Mt. - - 9.86 OK
Plot Depth Mt. - - 20.16 OK
Access Width Mt. - - 7.62 OK
Plot Frontage Mt. - - 9.86 OK
Coverage Area Sq.Mt. - 139.07 108.72 OK
FAR Area Sq.Mt. - 496.67 326.16 OK
Consumed FAR Sq.Mt. - 2.50 1.64 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 9.93 20.99 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 20.99 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.20 OK
Tree Cover (Plantation) - Angle Degree - 89.46 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
AA-1 (AA) Front Margin... 7.62 mt. Wide MainRoad Mt. 2.50 - 2.85 OK
Rear Margin Mt. 1.50 - 1.81 OK
Side1 Margin Mt. - - 0.56 OK
Side2 Margin Mt. 0.90 - 0.91 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
AA (AA) Height Mt. 14.28 9.00 OK
AA (AA) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
AA (AA) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
AA (AA) No. of Floors No. G + 5 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.067 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.254 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.158 OK
Fire Escape Staircase - Riser No. On Flight No. 16 5 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2 FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.067 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.254 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.158 OK
Fire Escape Staircase - Riser No. On Flight No. 16 5 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Fire Escape Staircase - Flight Width Mt. - 1.067 OK
Fire Escape Staircase - Tread Width Mt. - 0.254 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.500 OK
SUMP TANK Area Sq.Mt. - - 3.76 OK
Width Mt. - - 1.49 OK
Depth Mt. - - 2.53 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.48 OK
Width Mt. - - 0.54 OK
Depth Mt. - - 0.88 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.42 OK
Width Mt. - - 0.18 OK
Depth Mt. - - 2.34 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.69 OK
Width Mt. - - 0.95 OK
Depth Mt. - - 2.83 OK
Height Mt. - - - OK
AA (AA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) No Rule Defined
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)