Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 25-02-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0018/W21/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDhaiya
Taluka15
Architect Details
Architect NameLalan Prasad Singh
License No.DMC/ENG/0012/2019
Architect AddressEr. L P Singh, In Front of Binod Bihari Mahato, Chiragora, Dhanbad, Jharkhand
Architect EmailIDlalanprasadsingh.jh@gmail.com
Architect Mobile No8409877028
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No20, 21
NorthPlot No. - PLOT NO. 11
SouthRoad Width - 6.1
EastPlot No. - PLOT NO. 20
WestPlot No. - PLOT NO. 20
Owner's Details
NameCHAMPA DEVI, DEBAROTI DUTTA
AddressSAKET VIHAR, POLYTECHNIC ROAD, DHANBAD
Email IDamitkumarraj704@gmail.com
Mobile No7766913611
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 575.67
2 Plot area as per Document by Applicant 575.41
3 Physical area measured at site 575.41
4 Area as per Site Visit (Site Visit Report) 572.21
5Area as per Drawing 570.37

Area of Plot Considered : 570.37

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 570.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 570.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 510.26
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 60.11
60.11
Balance Plot Area 510.26

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 342.22
Proposed Coverage Area ( 49.41 % ) 281.80
Total Prop. Coverage Area ( 49.41 % ) 281.80
Balance coverage area ( 10.59 % ) 60.42
FAR CHECK
Perm. FAR Area ( 2.500 ) 1425.93
Total Perm. FAR area 1425.93
Residential FAR 1364.27
Proposed FAR Area 1370.20
Total Proposed FAR Area 1370.20
Consumed FAR (Factor) 2.40
Balance FAR Area 55.73
BUA CHECK
Total Proposed BuiltUp Area 1830.72


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.6 -
Road Widening Width 0.25 -
Plot size (as per measurement) 572.21 570.37
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 57.04 60.11 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
SUMP TANK - 60.11 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A1 (1A) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A1 (1A) 13.43 13.43 13.43 13.43 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (1A) Fourth Floor 2.40 - 2.50 2.40 - 2.40 2.40 - 2.40 OK
Third Floor 2.40 - 2.50 2.40 - 2.40 2.40 - 2.40 OK
Second Floor 2.75 - 2.81 2.75 - 2.75 2.40 - 2.75 OK
First Floor 2.75 - 2.81 2.75 - 2.75 2.40 - 2.75 OK
Ground Floor 2.75 - 2.81 2.75 - 2.75 2.40 - 2.75 OK
Basement Floor 2.40 - 2.81 2.40 - 2.75 2.10 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (1A) Terrace Floor - - 0.90 - - 0.90 - - 0.90 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A1 (1A) Basement Floor - - 0.90 - 299.24 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A1 (1A) - 299.24
Total - 299.24 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A1-1 (1A)   6.1 M WIDE ROAD 2.00 4.28 2.00 3.18 2.00 2.52 2.00 2.53 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A1 (1A) G + 4 5 - 20 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A1 (1A) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
342.22 281.80 OK
60% 49.41%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A1-1 (1A) - 281.80
  Total Prop. Coverage Area - 281.80
  Total Coverage Area 342.22 281.80

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Balcony Accessory Use Parking Resi. Stair
A1 (1A) 1 1874.62 43.90 1830.72 17.35 61.24 92.10 289.84 1364.26 5.93 1370.19 1370.19 20
Grand Total : 1 1874.62 43.90 1830.72 17.35 61.24 92.10 289.84 1364.26 5.93 1370.19 1370.19 20


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A1 (1A)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 299.24 5.93 299.24 5.93
Ground Floor 281.80 263.38 281.80 263.38
First Floor 312.42 275.22 312.42 275.22
Second Floor 312.42 275.22 312.42 275.22
Third Floor 312.42 275.22 312.42 275.22
Fourth Floor 312.42 275.22 312.42 275.22
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1830.72 1370.19 1830.72 1370.19


[-] UnitBUA Table for Building :A1 (1A)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN 1 FLAT 64.53 64.43 7 4
2 FLAT 67.05 66.98 7
3 FLAT 67.05 66.89 7
4 FLAT 68.05 67.94 7
TYPICAL - 1, 2, 3, 4 FLOOR PLAN 5 FLAT 72.18 64.43 7 16
6 FLAT 74.70 66.98 7
7 FLAT 74.70 66.89 7
8 FLAT 75.71 67.94 7
Total: - - 1455.87 1331.16 140 20


[-] Building :A1 (1A)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Balcony Accessory Use Parking Resi. Stair
Basement Floor 299.24 0.00 299.24 3.47 0.00 0.00 289.84 0.00 5.93 5.93 5.93 00
Ground Floor 290.58 8.78 281.80 0.00 0.00 18.42 0.00 263.38 0.00 263.38 263.38 04
First Floor 321.20 8.78 312.42 3.47 15.31 18.42 0.00 275.22 0.00 275.22 275.22 04
Second Floor 321.20 8.78 312.42 3.47 15.31 18.42 0.00 275.22 0.00 275.22 275.22 04
Third Floor 321.20 8.78 312.42 3.47 15.31 18.42 0.00 275.22 0.00 275.22 275.22 04
Fourth Floor 321.20 8.78 312.42 3.47 15.31 18.42 0.00 275.22 0.00 275.22 275.22 04
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1874.62 43.90 1830.72 17.35 61.24 92.10 289.84 1364.26 5.93 1370.19 1370.19 20
Total Number of Same Buildings : 1
Total : 1874.62 43.90 1830.72 17.35 61.24 92.10 289.84 1364.26 5.93 1370.19 1370.19 20
[-] Table 4c-2

  FAR Area
Building FAR Area:1370.20
Existing FAR Area :0.00
Perm.
1425.93
Prop.
1370.20
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A1-1 (1A) 6.1 M WIDE ROAD 3.50 4.28 2.50 3.08 2.50 2.52 2.50 2.53 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A1 (1A)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 1, 2, 3, 4 FLOOR PLAN BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK
BALCONY 1.20 1.17 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A1 (1A) 13.43 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A1 (1A)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.78 1.90 1.96 OK
GROUND FLOOR PLAN Lift 1.70 1.78 1.90 1.96 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.68 1.90 1.96 Failed
TYPICAL - 1, 2, 3, 4 FLOOR PLAN Lift 1.70 1.78 1.90 1.96 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A1 (1A) Residential Residential Bldg/Apartment 0 - 140 1 20.00 1.00 20 - - - - - - -
> 140 1.5 - 1 - - - - - - - -
> 0 1 20.00 - - - - - - 1 20 -
> 0 1 20.00 - - - 1 2 - - - -
Total : - - - - 20 21 - 2 2 - 20 23

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 21 262.50 OK
Total Car 20 250.00 21 262.50 OK
Visitor's Car Parking - - 2 25.00 OK
Total Visitor Parking 2 25.00 2 25.00 OK
TwoWheeler - - 23 46.00 OK
Total TwoWheeler 20 40.00 23 46.00 OK
Other Parking - - - 43.84 OK
Total 315.00 423.34 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY-04 3.60 - 4.10 OK
A1 (1A) BASEMENT FLOOR PLAN DRIVEWAY-1 3.60 - 3.60 OK
DRIVEWAY-2 3.60 - 6.17 OK
DRIVEWAY-3 3.60 - 6.17 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A1 (1A)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 0.927 0.250 0.254 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 0.927 0.250 0.254 0.200 0.156 - 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.927 - 0.254 - 0.000 - 0 - - 2.200 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN STAIRCASE 0.900 0.927 0.250 0.254 0.200 0.139 - 9 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
4.00 mt. long 1.50 mt. High 5.00 mt. Wide Natural Slope - 1.73 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A1 (1A) BASEMENT FLOOR PLAN 1 1 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A1 (1A)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
CHHAJJA 0.75 0.75 - 3.28 - 2.46 OK
CHHAJJA 0.75 0.75 - 3.28 - 2.46 OK
CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
CHHAJJA 0.75 0.70 - 3.28 - 2.29 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 6.80 - - 2.26 - - 3.02 - - 0.00 OK
RAIN WATER HARVESTING - - 3.99 - - 1.80 - - 2.22 - - 0.00 OK
ENT.GATE - - 0.12 - - 0.11 - - 1.16 - - 0.00 OK
KITCHENETTE 2.35X1.32 - 12.00 3.10 - - 1.32 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.56 - 12.00 3.66 - - 1.56 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.55 - 12.00 3.64 - - 1.55 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.55 - 12.00 3.64 - - 1.55 - - 2.35 - - 0.00 OK
Entrance Lobby - 12.00 4.38 - - 1.86 - - 2.36 - - 0.00 OK
KITCHENETTE 2.35X1.32 - 12.00 3.10 - - 1.32 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.56 - 12.00 3.66 - - 1.56 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.55 - 12.00 3.64 - - 1.55 - - 2.35 - - 0.00 OK
KITCHENETTE 2.35X1.55 - 12.00 3.64 - - 1.55 - - 2.35 - - 0.00 OK
Entrance Lobby - 12.00 4.38 - - 1.86 - - 2.36 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.80 - - 1.56 - - 1.79 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A1 (1A) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A1 (1A)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1, 2, 3, 4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 570.37 OK
  Plot Width - 25.22 OK
  Plot Depth - 22.61 OK
  Access Width 6.10 6.10 OK
  Plot Frontage - 25.21 OK
  Coverage Area 342.22 281.80 OK
  FAR Area
Bldg. FAR Area : 1370.20
Sanctioned FAR Area :0.00
1425.93 1370.20 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.5 mt., Rear 2.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.4 mt.in case of AC Room {As per Rule No.42.2.2}
(2) The height of all rooms for human habitation shall not be less than 2.4 mt.in case of AC Room {As per Rule No.42.2.2}
(3) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(4) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(5) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building KITCHENETTE 2.35X1.32
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building KITCHENETTE 2.35X1.56
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building KITCHENETTE 2.35X1.55
(12) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(13) No need to check distance from Building Entrance Lobby
(14) -
(15) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)