No Image Found   

Check List Report

Dhanbad Municipal Corporation

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 19-10-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0229/W22/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhelatand
Taluka15
Architect Details
Architect NameANJALI KUMARI
License No.DMC/ARC/0013/2022
Architect AddressNEAR S.S.L.NT COLLEGE ,LUBY CIRCULAR ROAD
Architect EmailIDKUMARIANJALI1402@GMAIL.COM
Architect Mobile No7061816303
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No569,OLD-331
NorthPlot No. - PART OF THIS PLOT
SouthPlot No. - LAND OF MADHURI DEVI
EastPlot No. - 7.62
WestPlot No. - PART OF THIS PLOT
Owner's Details
NameNITI KUMARI
AddressHOUSE NO-22,LUBY,CIRCULAR ROAD DHANBAD
Email IDnitikchandra@gmail.com
Mobile No8986610560
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 267.19
2 Plot area as per Document by Applicant 267.19
3 Physical area measured at site 267.19
4 Area as per Site Visit (Site Visit Report) 267.19
5Area as per Drawing 267.07

Area of Plot Considered : 267.07

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 267.07
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 267.07
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 243.08
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 23.98
23.98
Balance Plot Area 243.08

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 160.24
Proposed Coverage Area ( 59.98 % ) 160.18
Total Prop. Coverage Area ( 59.98 % ) 160.18
Balance coverage area ( 0.02 % ) 0.06
FAR CHECK
Perm. FAR Area ( 2.500 ) 667.68
Total Perm. FAR area 667.68
Residential FAR 429.65
Proposed FAR Area 429.65
Total Proposed FAR Area 429.65
Consumed FAR (Factor) 1.61
Balance FAR Area 238.03
BUA CHECK
Total Proposed BuiltUp Area 480.54


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 7.62 7.62
Proposed Road Width as per Master Plan 7.62 -
Road Widening Width 0 -
Plot size (as per measurement) 267.19 267.07
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 267.07 OK
Plot Width Mt. - - 12.19 OK
Plot Depth Mt. - - 21.91 OK
Access Width Mt. - - 7.62 OK
Plot Frontage Mt. - - 12.19 OK
Coverage Area Sq.Mt. - 160.24 160.18 OK
FAR Area Sq.Mt. - 667.68 429.65 OK
Consumed FAR Sq.Mt. - 2.50 1.61 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 13.35 23.98 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 23.98 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.37 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 4 OK
RESI -1 (BLDG AA) Front Margin... 7.62 mt. Wide MainRoad Mt. 3.00 - 4.03 OK
Rear Margin Mt. 1.80 - 2.15 OK
Side1 Margin Mt. 0.90 - 1.01 OK
Side2 Margin Mt. 0.90 - 1.01 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
RESI (BLDG AA) Height Mt. 15.46 9.00 OK
RESI (BLDG AA) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
RESI (BLDG AA) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
RESI (BLDG AA) No. of Floors No. G + 5 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.119 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 4 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.119 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 4 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.119 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 4 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.119 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
SUMP TANK Area Sq.Mt. - - 4.36 OK
Width Mt. - - 1.72 OK
Depth Mt. - - 2.54 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.61 OK
Width Mt. - - 1.34 OK
Depth Mt. - - 2.69 OK
Height Mt. - - - OK
Overhead WaterTank Area Sq.Mt. - - 14.19 OK
Width Mt. - - 2.77 OK
Depth Mt. - - 5.11 OK
Height Mt. - - 1.50 OK
ENT.GATE Area Sq.Mt. - - 0.93 OK
Width Mt. - - 0.26 OK
Depth Mt. - - 3.66 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.61 OK
Width Mt. - - 1.97 OK
Depth Mt. - - 2.85 OK
Height Mt. - - - OK
RESI (BLDG AA) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
PLOT 3.50 mt. long 1.50 mt. High 3.00 mt. Wide Natural Slope - Width Mt. - 3.00 OK
3.50 mt. long 1.50 mt. High 3.00 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
3.50 mt. long 1.50 mt. High 3.00 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. RESI (BLDG AA) - GROUND FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)