No Image Found   

Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 29-02-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0069/W18/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePanderpala
Taluka15
Architect Details
Architect NameKumud Kanchan
License No.DMC/ARC/0002/2016
Architect AddressKumud Kanchan D/O Sri R. B. Singh Mahapura House, 15A Cmwo Co-operative Colony, Koyla Nagar, Dhanbad, Jharkhand, 826005 Mobile No.- 7633999700
Architect EmailIDkumudkanchan28@gmail.com
Architect Mobile No7633999700
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD - 307, NEW - 167
NorthPlot No. - PART OF THIS PLOT
SouthPlot No. - RAM PRAVESH LOHAR
EastRoad Width - 12.2
WestPlot No. - GOLDEN
Owner's Details
NameMD. SAJID HUSSAIN
AddressPANDERPALA DHANBAD
Email IDashish_bhnu_singh@yahoo.co.in
Mobile No8825140016
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 534.39
2 Plot area as per Document by Applicant 533.30
3 Physical area measured at site 533.30
4 Area as per Site Visit (Site Visit Report) 533.30
5Area as per Drawing 532.88

Area of Plot Considered : 532.88

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 532.88
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 532.88
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 499.21
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 33.66
33.66
Balance Plot Area 499.21

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 266.44
Proposed Coverage Area ( 47.77 % ) 254.58
Total Prop. Coverage Area ( 47.77 % ) 254.58
Balance coverage area ( 2.23 % ) 11.86
FAR CHECK
Perm. FAR Area ( 2.500 ) 1332.20
Total Perm. FAR area 1332.20
Commercial FAR 1300.01
Proposed FAR Area 1300.01
Total Proposed FAR Area 1300.01
Consumed FAR (Factor) 2.44
Balance FAR Area 32.19
BUA CHECK
Total Proposed BuiltUp Area 1640.59


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 12.2 -
Road Widening Width 0 -
Plot size (as per measurement) 533.3 532.88
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 26.64 33.66 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 33.66 0.00 0.00 - 3.45 - 74.71 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 5 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A1 (A1) Commercial Shop Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A1 (A1) 25.85 15.13 15.13 15.13 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (A1) Fourth Floor 2.75 - 2.87 2.75 - 2.77 2.40 - 2.77 OK
Third Floor 2.75 - 2.87 2.75 - 2.77 2.40 - 2.77 OK
Second Floor 2.75 - 2.87 2.75 - 2.77 2.40 - 2.77 OK
First Floor 2.75 - 2.87 2.75 - 2.77 2.40 - 2.77 OK
Ground Floor 2.75 - 3.65 2.75 - 3.55 2.40 - 3.55 OK
Basement Floor 2.40 - 3.37 2.40 - 3.27 2.10 - 3.27 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (A1) Terrace Floor - - 0.91 - - 0.91 - - 0.91 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A1 (A1) Basement Floor - - 0.90 - 254.57 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A1 (A1) - 254.57
Total - 254.57 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A1-1 (A1)   12.2 M WIDEROAD 2.00 7.51 2.00 4.55 2.00 2.02 2.00 2.03 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A1 (A1) - 5 - 5 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A1 (A1) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
266.44 254.58 OK
50% 47.77%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A1-1 (A1) - 254.58
  Total Prop. Coverage Area - 254.58
  Total Coverage Area 266.44 254.58

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Commercial
A1 (A1) 1 1640.59 29.44 56.56 244.96 1300.01 1300.02 1300.02 05
Grand Total : 1 1640.59 29.44 56.56 244.96 1300.01 1300.02 1300.02 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A1 (A1)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 254.57 0.00 254.57 0.00
Ground Floor 254.58 254.58 254.58 254.58
First Floor 282.86 261.36 282.86 261.36
Second Floor 282.86 261.36 282.86 261.36
Third Floor 282.86 261.36 282.86 261.36
Fourth Floor 282.86 261.36 282.86 261.36
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1640.59 1300.02 1640.59 1300.02


[-] UnitBUA Table for Building :A1 (A1)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHOP SHOP 247.22 247.12 14 1
TYPICAL - 1, 2, 3, 4 FLOOR PLAN SHOP SHOP 275.50 247.14 14 4
Total: - - 1349.21 1235.67 70 5


[-] Building :A1 (A1)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Commercial
Basement Floor 254.57 0.00 0.00 244.96 0.00 0.00 0.00 00
Ground Floor 254.58 0.00 0.00 0.00 254.58 254.58 254.58 01
First Floor 282.86 7.36 14.14 0.00 261.36 261.36 261.36 01
Second Floor 282.86 7.36 14.14 0.00 261.36 261.36 261.36 01
Third Floor 282.86 7.36 14.14 0.00 261.36 261.36 261.36 01
Fourth Floor 282.86 7.36 14.14 0.00 261.36 261.36 261.36 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1640.59 29.44 56.56 244.96 1300.01 1300.02 1300.02 05
Total Number of Same Buildings : 1
Total : 1640.59 29.44 56.56 244.96 1300.01 1300.02 1300.02 05
[-] Table 4c-2

  FAR Area
Building FAR Area:1300.01
Existing FAR Area :0.00
Perm.
1332.20
Prop.
1300.01
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A1-1 (A1) 12.2 M WIDEROAD 7.50 7.51 4.50 4.55 2.00 2.02 2.00 2.03 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A1 (A1)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 1, 2, 3, 4 FLOOR PLAN BALCONY 0.90 0.89 OK
BALCONY 0.90 0.93 Failed



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A1 (A1) 15.13 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :A1 (A1)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.72 1.90 2.13 OK
Lift 1.70 1.72 1.90 2.14 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN Lift 1.70 1.72 1.90 2.13 OK
Lift 1.70 1.72 1.90 2.14 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.72 1.90 2.13 OK
Lift 1.70 1.72 1.90 2.14 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A1 (A1) Commercial Shop > 0 50 1248.06 1 17 - - - -
> 0 50 1248.06 - - - 1 52 -
Total : - - - - 17 19 - 52 29

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 12 150.76 OK
Two Stack.Car - - 7 87.50 OK
Total Car 17 212.50 19 238.26 OK
TwoWheeler - - 29 58.00 OK
Two Stack. TwoWheeler - - 29 58.00 OK
Total TwoWheeler 52 104.00 58 116.00 OK
Total 316.50 470.26 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY-3 3.60 - 6.87 OK
A1 (A1) BASEMENT FLOOR PLAN DRIVEWAY-1 3.60 - 5.00 OK
DRIVEWAY-2 3.60 - 5.00 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A1 (A1)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.250 0.200 0.152 - 12 - - 0.000 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.144 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.254 - 0.000 - 0 - - 2.134 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
5.00 mt. long 1.50 mt. High 5.00 mt. Wide Natural Slope - 2.52 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A1 (A1) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.01 - - 1.39 - - 1.45 - - 0.00 OK
RAIN WATER HARVESTING - - 1.00 - - 0.99 - - 1.01 - - 0.00 OK
ENT.GATE - - 0.49 - - 0.28 - - 1.95 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A1 (A1) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A1 (A1)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 1, 2, 3, 4 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:BASEMENT FLOOR PLAN



No Room Found.



   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 532.88 OK
  Plot Width - 13.31 OK
  Plot Depth - 40.05 OK
  Access Width 6.10 12.20 OK
  Plot Frontage - 32.30 OK
  Coverage Area 266.44 254.58 OK
  FAR Area
Bldg. FAR Area : 1300.01
Sanctioned FAR Area :0.00
1332.20 1300.01 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 10-15 mt., Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)