Detail Scrutiny Report

Dhanbad Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 31-07-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0192/W24/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaraidhela
Taluka15
Architect Details
Architect NameAJAY KUMAR KESARI
License No.DMC/ENG/0007/2021
Architect AddressSURYA VIHAR COLONY, BARTAND , PO. - CMRI, DHANBAD
Architect EmailIDajaykumarkesari29@gmail.com
Architect Mobile No9608920244
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD-3245(PART), NEW-2039
NorthPlot No. - NEW PLOT NO.- 2040,2041,2042
SouthPlot No. - PART OF THIS PLOT
EastPlot No. - NEW PLOT NO.- 2046
WestRoad Width - ROAD
Owner's Details
NameSONU KUMAR NAGI
Address70A, SARAIDHELA, NEAR CANARA BANK, P.S.- SARAIDHELA, DHANBAD
Email IDsonunagi074@gmail.com
Mobile No7870727651
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 100.37
2 Plot area as per Document by Applicant 100.10
3 Physical area measured at site 100.10
4 Area as per Site Visit (Site Visit Report) 100.06
5Area as per Drawing 100.04

Area of Plot Considered : 100.04

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 100.04
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 100.04
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 93.13
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 6.91
6.91
Balance Plot Area 93.13

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 70.03
Proposed Coverage Area ( 51.99 % ) 52.01
Total Prop. Coverage Area ( 51.99 % ) 52.01
Balance coverage area ( 18.01 % ) 18.02
FAR CHECK
Perm. FAR Area ( 1.800 ) 180.07
Total Perm. FAR area 180.07
Residential FAR 156.04
Proposed FAR Area 156.04
Total Proposed FAR Area 156.04
Consumed FAR (Factor) 1.56
Balance FAR Area 24.03
BUA CHECK
Total Proposed BuiltUp Area 240.00


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.8 4.80
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 0 -
Plot size (as per measurement) 100.06 100.04
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 5.00 6.91 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 6.91 0.00 0.00 - 1.26 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 5 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (B) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (B) 9.74 8.55 8.55 8.55 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (B) Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Basement Floor 2.40 - 2.50 2.40 - 2.40 2.10 - 2.30 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (B) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (B) Basement Floor 0.90 1.50 1.00 - 60.00 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (B) - 60.00
Total - 60.00 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (B)   4.80 mt. Wide MainRoad 2.50 2.54 1.50 1.52 0.90 0.94 - 0.00 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (B) G + 2 3 - 1 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (B) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
70.03 52.01 OK
70% 51.99%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (B) - 52.01
  Total Prop. Coverage Area - 52.01
  Total Coverage Area 70.03 52.01

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Parking Resi.
A (B) 1 240.00 31.96 52.01 156.03 156.03 156.03 01
Grand Total : 1 240.00 31.96 52.01 156.03 156.03 156.03 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (B)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 60.00 0.00 60.00 0.00
Ground Floor 60.00 52.01 60.00 52.01
First Floor 60.00 52.01 60.00 52.01
Second Floor 60.00 52.01 60.00 52.01
Terrace Floor 0.00 0.00 0.00 0.00
Total : 240.00 156.03 240.00 156.03


[-] UnitBUA Table for Building :A (B)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 180.01 179.89 4 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 6 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 6 0
Total: - - 180.01 179.89 16 1


[-] Building :A (B)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Parking Resi.
Basement Floor 60.00 7.99 52.01 0.00 0.00 0.00 00
Ground Floor 60.00 7.99 0.00 52.01 52.01 52.01 01
First Floor 60.00 7.99 0.00 52.01 52.01 52.01 00
Second Floor 60.00 7.99 0.00 52.01 52.01 52.01 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 240.00 31.96 52.01 156.03 156.03 156.03 01
Total Number of Same Buildings : 1
Total : 240.00 31.96 52.01 156.03 156.03 156.03 01
[-] Table 4c-2

  FAR Area
Building FAR Area:156.04
Existing FAR Area :0.00
Perm.
180.07
Prop.
156.04
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (B) 4.80 mt. Wide MainRoad 2.50 2.54 1.50 1.52 0.90 0.94 - 0.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (B)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (B)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN Fire Escape Staircase 0.900 0.914 0.250 0.254 0.200 0.000 16 0 - - 0.000 OK
GROUND FLOOR PLAN Fire Escape Staircase 0.900 0.914 0.250 0.254 0.200 0.136 16 11 - - 0.000 OK
FIRST FLOOR PLAN Fire Escape Staircase 0.900 0.914 0.250 0.254 0.200 0.136 16 11 - - 0.000 OK
SECOND FLOOR PLAN Fire Escape Staircase 0.900 0.914 0.250 0.254 0.200 0.136 16 11 - - 0.000 OK
TERRACE FLOOR PLAN Fire Escape Staircase - 0.914 - 0.254 - 0.000 16 0 - - 2.437 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
3.50 mt. long 1.50 mt. High 3.00 mt. Wide Natural Slope - 2.50 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (B) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.67 - - 1.26 - - 2.13 - - 0.00 OK
RAIN WATER HARVESTING - - 1.08 - - 0.91 - - 1.18 - - 0.00 OK
ENT.GATE - - 0.69 - - 0.23 - - 3.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.56 - - 1.16 - - 1.35 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (B) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (B)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 100.04 OK
  Plot Width - 5.83 OK
  Plot Depth - 17.15 OK
  Access Width - 4.80 OK
  Plot Frontage - 5.72 OK
  Coverage Area 70.03 52.01 OK
  FAR Area
Bldg. FAR Area : 156.04
Sanctioned FAR Area :0.00
180.07 156.04 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) No Rule Defined
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.35x3.65 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.52x2.74 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall2.87x1.33 No Rule Defined
Hall4.91x3.65 No Rule Defined
Kitchen1.83x3.05 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Living/dining4.91x3.65 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Study Room2.58x3.05 No Rule Defined
Toilet1.45x2.63 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.52x2.28 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.75x1.22 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Utility1.22x1.83 No Rule Defined
Utility1.45x2.86 No Rule Defined
Verandah2.86x1.97 No Rule Defined
Verandah2.88x2.28 No Rule Defined
Wc1.55x1.97 No Rule Defined