[-] Proposal Information (Table 1)
General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityDHANBAD MUNICIPAL CORPORATION
Inward_NoDMC/BP/0296/W20/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHirapur
Taluka15
Architect Details
Architect NameLalan Prasad Singh
License No.DMC/ENG/0012/2019
Architect AddressEr. L P Singh, In Front of Binod Bihari Mahato, Chiragora, Dhanbad, Jharkhand
Architect EmailIDlalanprasadsingh.jh@gmail.com
Architect Mobile No7004488585
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No10,11,12,13,15,17,3,5,97
NorthRoad Width - 6.1
SouthPlot No. - plot
EastPlot No. - plot
WestPlot No. - plot

[-]Owner/Applicant details
NameABHINAV CONSTRUCTION
AddressJHARUDIH POLYTECHNIC, DHANBAD
Email IDritesh.abhinav@gmail.com
Mobile No9386915121
  [-] Plot Details (Table 2)
[-] Area From Document (Table 2a)
No. Form Area(Sq. Mt.)
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 809.66
2 Plot area as per Document by Applicant 809.66
3 Physical area measured at site 809.66
4 Area as per Site Visit (Site Visit Report) 743.00
5Area as per Drawing 742.29

Area of Plot Considered : 742.29
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 742.29
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 742.29
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 666.15
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 76.14
76.14
Balance Plot Area 666.15

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 445.37
Proposed Coverage Area ( 51.83 % ) 384.75
Total Prop. Coverage Area ( 51.83 % ) 384.75
Balance coverage area ( 8.17 % ) 60.62
FAR CHECK
Perm. FAR Area ( 2.500 ) 1855.72
Total Perm. FAR area 1855.72
Residential FAR 1816.85
Proposed FAR Area 1816.85
Total Proposed FAR Area 1816.85
Consumed FAR (Factor) 2.45
Balance FAR Area 38.87
BUA CHECK
Total Proposed BuiltUp Area 2595.35


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 743 742.29
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK



[-] Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK
[-] Plot Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 742.29 OK
Plot Width Mt. - - 23.82 OK
Plot Depth Mt. - - 31.16 OK
Access Width Mt. 6.10 - 6.10 OK
Plot Frontage Mt. - - 26.87 OK
Coverage Area Sq.Mt. - 445.37 384.75 OK
FAR Area Sq.Mt. - 1855.72 1816.85 OK
Consumed FAR Sq.Mt. - 2.50 2.45 OK
[-] Common Plot
Name Description Unit Reqd Perm Proposed Status
Common Plot Checks Common Plot - Total Area Sq.Mt. 74.23 76.14 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 76.14 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.66 OK
Tree Cover (Plantation) - Angle Degree - 82.13 OK
Tree Cover (Plantation) - Access Mt. 5.9 mtr MAINROAD Access Road OK
[-] Tree
Name Description Unit Reqd Perm Proposed Status
Tree Tree - Nos Of Trees No. 4 11 OK
[-] Parking
Name Description Unit Reqd Perm Proposed Status
Car In Area Sq.Mt. - - 250.00 OK
Total Car In Area Sq.Mt. 250.00 - 250.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 25.00 OK
Total Visitor Parking In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 42.00 OK
Total TwoWheeler In Area Sq.Mt. 40.00 - 42.00 OK
Other Parking In Area Sq.Mt. - - 143.68 OK
[-] DriveWay
Name Description Unit Reqd Perm Proposed Status
DriveWay PLOT - - - DS1 - Width No. 3.60 - 4.46 OK
AA (B1) - BASEMENT FLOOR PLAN - DB1 - Width No. 3.60 - 6.19 OK
AA (B1) - BASEMENT FLOOR PLAN - DB2 - Width No. 3.60 - 6.49 OK
[-] PWork to Plot Margin
Name Description Unit Reqd Perm Proposed Status
AA-1 (B1) Front Margin... 6.1 MTR WIDE MAINROAD Mt. 4.00 - 5.33 OK
Rear Margin Mt. 3.50 - 3.50 OK
Side1 Margin Mt. 2.50 - 2.56 OK
Side2 Margin Mt. 2.50 - 2.52 OK
[-] Building Height
Name Description Unit Reqd Perm Proposed Status
AA (B1) Height Mt. 14.48 14.38 OK
[-] Floor Height
Name Description Unit Reqd Perm Proposed Status
AA (B1) Fourth Floor - Height Mt. 2.75 - 2.88 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.75 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Third Floor - Height Mt. 2.75 - 2.88 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 2.88 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 2.88 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 2.88 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Basement Floor - Height Mt. 2.40 - 2.74 OK
Basement Floor - Clear Height Mt. 2.40 - 2.62 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.62 OK
[-] Parapet Height
Name Description Unit Reqd Perm Proposed Status
AA (B1) Terrace Floor - Height Mt. - - 1.11 OK
Terrace Floor - Clear Height Mt. - - 1.11 OK
Terrace Floor - Beam Clear Height Mt. - - 1.11 OK
[-] Above Ground Level Floor Height
Name Description Unit Reqd Perm Proposed Status
AA (B1) Basement Floor - Height of Basement Floor above GL Mt. - - 0.90 OK
Basement Floor - Area Sq.Mt. - 438.28 OK
Basement Floor - Ventilation Area Sq.Mt. - 5.37 OK
[-] Basement Floor Area
Name Description Unit Reqd Perm Proposed Status
AA (B1) Area Sq.Mt. - 438.28 OK
Status OK
Total Area Sq.Mt. - 438.28 OK
[-] Basement Margin
Name Description Unit Reqd Perm Proposed Status
AA-1 (B1) Basement Front Margin... 6.1 MTR WIDE MAINROAD Mt. 2.00 - 5.02 OK
Basement Rear Margin Mt. 2.00 - 2.23 OK
Basement Side1 Margin Mt. 2.00 - 2.67 OK
Basement Side2 Margin Mt. 2.00 - 2.04 OK
[-] Basement Floor No
Name Description Unit Reqd Perm Proposed Status
AA (B1) No. of Basement Floor No. 1 1 OK
[-] Floors Number
Name Description Unit Reqd Perm Proposed Status
AA (B1) No. of Floors No. G + 4 5 OK
No. of Tenements No. - 20 OK
[-] Balcony Details
Name Description Unit Reqd Perm Proposed Status
AA (B1) TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 1 - Width Mt. 1.20 1.00 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 2 - Width Mt. 1.20 1.00 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 3 - Width Mt. 1.20 1.00 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 4 - Width Mt. 1.20 1.00 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 5 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 6 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 7 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 8 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 9 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 10 - Width Mt. 1.20 0.91 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - BALCONY 11 - Width Mt. 1.20 0.91 OK
[-] Lift Count Details
Name Description Unit Reqd Perm Proposed Status
AA (B1) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
[-] Lift Details
Name Description Unit Reqd Perm Proposed Status
AA (B1) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.17 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.17 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.90 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN - Lift - Depth Mt. 1.90 2.17 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.17 OK
[-] Stair Details
Name Description Unit Reqd Perm Proposed Status
BASEMENT FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.219 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.305 OK
Fire Escape Staircase - Riser Height Mt. 0.200 - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.219 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.305 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.144 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.219 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.305 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.144 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Fire Escape Staircase - Flight Width Mt. - 1.219 OK
Fire Escape Staircase - Tread Width Mt. - 0.305 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.438 OK
[-] Accessory Use Details
Name Description Unit Reqd Perm Proposed Status
Toilet Area Sq.Mt. - 5.00 4.71 OK
Width Mt. - - 2.01 OK
Depth Mt. - - 2.35 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 5.18 OK
Width Mt. - - 1.42 OK
Depth Mt. - - 3.64 OK
Height Mt. - - - OK
Garbage Store Area Sq.Mt. - - 13.70 OK
Width Mt. - - 2.55 OK
Depth Mt. - - 5.37 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.03 OK
Width Mt. - - 1.76 OK
Depth Mt. - - 2.29 OK
Height Mt. - - - OK
Overhead WaterTank Area Sq.Mt. - - 11.63 OK
Width Mt. - - 2.17 OK
Depth Mt. - - 5.36 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 2.80 OK
Width Mt. - - 0.41 OK
Depth Mt. - - 6.79 OK
Height Mt. - - - OK
Area Sq.Mt. - - 2.80 OK
Width Mt. - - 0.41 OK
Depth Mt. - - 6.79 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 4.93 OK
Width Mt. - - 1.35 OK
Depth Mt. - - 3.64 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.63 OK
Width Mt. - - 1.61 OK
Depth Mt. - - 1.64 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 1.51 OK
Width Mt. - - 1.11 OK
Depth Mt. - - 1.37 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.98 OK
Width Mt. - - 1.51 OK
Depth Mt. - - 2.63 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.70 OK
Width Mt. - - 1.51 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.17 OK
Width Mt. - - 2.54 OK
Depth Mt. - - 2.82 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.93 OK
Width Mt. - - 1.35 OK
Depth Mt. - - 3.64 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.63 OK
Width Mt. - - 1.61 OK
Depth Mt. - - 1.64 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 1.51 OK
Width Mt. - - 1.11 OK
Depth Mt. - - 1.37 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.98 OK
Width Mt. - - 1.51 OK
Depth Mt. - - 2.63 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.70 OK
Width Mt. - - 1.51 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.17 OK
Width Mt. - - 2.54 OK
Depth Mt. - - 2.82 OK
Height Mt. - - - OK
TOILET1.52X2.44 Area Sq.Mt. - 12.00 3.72 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.72 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
TOILET1.52X2.63 Area Sq.Mt. - 12.00 4.01 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 2.63 OK
Height Mt. - - - OK
TOILET2.61X1.52 Area Sq.Mt. - 12.00 3.98 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 2.61 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 12.03 OK
Width Mt. - - 3.14 OK
Depth Mt. - - 3.84 OK
Height Mt. - - - OK
[-] Accessory Use No Details
Name Description Unit Reqd Perm Proposed Status
AA (B1) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 2 OK
[-] Ramp Details
Name Description Unit Reqd Perm Proposed Status
PLOT 4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Width Mt. - 4.50 OK
4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Slope Ratio - - - OK
4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Width Mt. - 4.50 OK
4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
4.50 mt. Long 1.5 mt. High 5.32 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. AA (B1) - BASEMENT FLOOR PLAN - No. No. 1 2 OK
[-] Room Details
    All Rooms are as per Rule in Room Checking



NOTE : This report is generated based on the inputs or drawing provided by the Applicant. The approval is subjected to further verification by concerned scrutiny officer.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. We are not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation and MADA Area, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Dhanbad Municipal Corporation and MADA Area, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 21-27 mt., Margin required in Front shall be 4.0 mt., Rear 3.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) No Rule Defined
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) -
(6) No need to check distance from Building Garbage Store
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building RAIN WATER HARVESTING
(9) -
(10) No need to check distance from Building Overhead WaterTank
(11) No need to check distance from Building ENT.GATE
(12) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(13) No need to check distance from Building Entrance Lobby
(14) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(15) No need to check distance from Building TOILET1.52X2.44
(16) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(17) No need to check distance from Building TOILET1.52X2.63
(18) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(19) No need to check distance from Building TOILET2.61X1.52
(20) -
(21) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room2.92x4.12 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.01x3.58 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.04x3.83 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.04x3.96 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.04x4.14 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.04x4.27 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.19x4.20 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.22x3.06 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.79x4.00 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.80x3.58 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.85x3.05 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.33x3.73 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dining/kitchen0.76x2.54 Area for Kitchen-dinning shall be Mini. 7.5 sq.mt. having side mini. 2.1 mt. {Rule No. 42.3.2}
Dining/kitchen2.62x5.58 Area for Kitchen-dinning shall be Mini. 7.5 sq.mt. having side mini. 2.1 mt. {Rule No. 42.3.2}
Dining/kitchen2.62x5.87 Area for Kitchen-dinning shall be Mini. 7.5 sq.mt. having side mini. 2.1 mt. {Rule No. 42.3.2}
Dining/kitchen4.60x3.36 Area for Kitchen-dinning shall be Mini. 7.5 sq.mt. having side mini. 2.1 mt. {Rule No. 42.3.2}
Hall3.96x4.89 No Rule Defined
Hall4.08x5.47 No Rule Defined
Hall4.63x5.49 No Rule Defined
Hall4.67x4.88 No Rule Defined
Toilet1.52x2.63 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.57x2.47 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.31x1.52 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.55x1.52 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.61x1.52 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Wc1.45x2.29 No Rule Defined
Wc2.25x1.52 No Rule Defined