No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 17-04-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0010/2019/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageSamlong
Taluka0
Layout Sanction Date7/8/2019
Architect Details
Architect NameAnup Nigam
License No.JIADA/ARC/0014/2018
Architect AddressB-328, 3rdFloor, Pacific Business Park, Plot No-37/1, Site-IV, Sahibabad Industrial Area, Ghaziabad-201010
Architect EmailIDaranupnigam@gmail.com
Architect Mobile No9811282552
Plot Details
Plot Use Industrial
Plot SubUse Industrial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No4 & 3 P
NorthPlot No. -
SouthRoad Width -
EastRoad Width -
WestPlot No. -
Owner's Details
NameMIMEC IT PARK PVT LTD Through MR. RAMAKANT SINGH
AddressPLOT NO-4,NAMKUM,INDUSTRIAL AREA,NAMKUM,RANCHI
Email IDmimecelectronicsp@yahoo.com
Mobile No9234601385
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 4310.05
2 Plot area as per Document by Applicant 4310.05
3 Physical area measured at site 4310.05
4 Area as per Site Visit (Site Visit Report) 4309.99
5Area as per Drawing 4301.75

Area of Plot Considered : 4301.75

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyIndustrial
Plot SubUse Industrial Building
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 4301.75
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 4301.75
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3837.11
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 464.64
464.64
Balance Plot Area 3837.11

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 2150.88
Proposed Coverage Area ( 32.56 % ) 1400.79
Total Prop. Coverage Area ( 32.56 % ) 1400.79
Balance coverage area ( 17.44 % ) 750.09
FAR CHECK
Perm. FAR Area ( 2.000 ) 8603.50
Total Perm. FAR area 8603.50
Industrial FAR 8256.54
Proposed FAR Area 8313.80
Total Proposed FAR Area 8313.80
Consumed FAR (Factor) 1.93
Balance FAR Area 289.70
BUA CHECK
Total Proposed BuiltUp Area 9849.98


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 15 15.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 4309.99 4301.75
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 430.18 464.64 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 464.64 0.00 0.00 - 5.61 - 88.61 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Industrial Industrial Building Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 30.00 21.60 21.60 21.60 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Fifth Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
Fourth Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
Third Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
Second Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
First Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
Ground Floor 2.75 - 3.60 2.75 - 3.40 2.40 - 3.20 OK
Basement Floor 2.40 - 3.35 2.40 - 3.15 2.10 - 2.95 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (BUILDING) Basement Floor 0.90 1.50 1.16 - 1400.79 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (BUILDING) - 1400.79
Total - 1400.79 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (BUILDING)   15 METER WIDE MAIN ROAD 7.50 11.83 4.50 13.23 4.50 7.30 4.50 14.46 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) - 6 - 0 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (BUILDING) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
2150.88 1400.79 OK
50% 32.56%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 1400.79
  Total Prop. Coverage Area - 1400.79
  Total Coverage Area 2150.88 1400.79

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.)
Cutout Lift Accessory Use Archi.Proj. Ramp Parking Industrial Stair
A (BUILDING) 1 9857.63 7.65 9849.98 9179.37 670.61 109.20 49.35 11.48 40.80 1325.34 7695.46 561.08 45.69 8313.81 8313.81
Grand Total : 1 9857.63 7.65 9849.98 9179.37 670.61 109.20 49.35 11.48 40.80 1325.34 7695.46 561.08 45.69 8313.81 8313.81


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Basement Floor 57.25 1343.54 57.25 0.00 57.25 1343.54 57.25 0.00
Ground Floor 52.28 1400.79 0.00 1383.79 52.28 1400.79 0.00 1383.79
First Floor 0.00 1400.80 0.00 1377.60 0.00 1400.80 0.00 1377.60
Second Floor 0.00 1400.80 0.00 1377.60 0.00 1400.80 0.00 1377.60
Third Floor 0.00 1400.80 0.00 1377.60 0.00 1400.80 0.00 1377.60
Fourth Floor 0.00 1400.80 0.00 1377.60 0.00 1400.80 0.00 1377.60
Fifth Floor 561.08 831.84 561.08 801.29 561.08 831.84 561.08 801.29
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 670.61 9179.37 618.35 7695.46 670.61 9179.37 618.35 7695.46




[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.)
Lift Accessory Use Archi.Proj. Ramp Parking Industrial Stair
Basement Floor 1400.79 1343.54 57.25 18.20 0.00 0.00 0.00 1325.34 0.00 0.00 45.69 57.25 57.25
Ground Floor 1453.07 1400.79 52.28 0.00 17.00 11.48 40.80 0.00 1383.79 0.00 0.00 1383.79 1383.79
First Floor 1400.80 1400.80 0.00 18.20 5.00 0.00 0.00 0.00 1377.60 0.00 0.00 1377.60 1377.60
Second Floor 1400.80 1400.80 0.00 18.20 5.00 0.00 0.00 0.00 1377.60 0.00 0.00 1377.60 1377.60
Third Floor 1400.80 1400.80 0.00 18.20 5.00 0.00 0.00 0.00 1377.60 0.00 0.00 1377.60 1377.60
Fourth Floor 1400.80 1400.80 0.00 18.20 5.00 0.00 0.00 0.00 1377.60 0.00 0.00 1377.60 1377.60
Fifth Floor 1392.92 831.84 561.08 18.20 12.35 0.00 0.00 0.00 801.29 561.08 0.00 1362.37 1362.37
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 9849.98 9179.37 670.61 109.20 49.35 11.48 40.80 1325.34 7695.46 561.08 45.69 8313.81 8313.81
Total Number of Same Buildings : 1
Total : 9849.98 9179.37 670.61 109.20 49.35 11.48 40.80 1325.34 7695.46 561.08 45.69 8313.81 8313.81
[-] Table 4c-2

  FAR Area
Building FAR Area:8313.80
Existing FAR Area :0.00
Perm.
8603.50
Prop.
8313.80
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 15 METER WIDE MAIN ROAD 7.50 11.83 4.50 13.23 4.50 7.30 4.50 14.46 OK






[-] Inner Building Details (Table 6)
   
   
[-] Passage Details

[-] For Building :A (BUILDING)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
FIFTH FLOOR PLAN 2.10 mt. Wide Passage 53.18 1.00 2.10 - 25.32 OK

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING) 21.60 2 3 - 0 12 44 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.95 2.50 2.55 OK
PASSENGER LIFT for 13 Persons 1.90 1.95 2.50 2.55 OK
PASSENGER LIFT for 18 Persons 1.70 2.50 1.90 3.30 OK
Lift Lobby 1.70 3.30 1.90 3.50 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.95 1.90 2.55 OK
Lift Machine Room 1.70 1.95 1.90 2.55 OK
Lift Machine Room 1.70 2.50 1.90 3.30 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Industrial Industrial Building > 0 400 561.08 1 1 - - - -
> 0 400 561.08 - - - 1 3 -
Total : - - - - 1 31 - 3 40

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 31 387.50 OK
Total Car 1 12.50 31 387.50 OK
TwoWheeler - - 40 80.00 OK
Total TwoWheeler 3 6.00 40 80.00 OK
Other Parking - - - 937.84 OK
Total 18.50 1485.34 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (BUILDING) BASEMENT FLOOR PLAN DRIVEWAY 4.50 - 6.69 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.500 0.250 0.300 0.200 0.000 - 0 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.300 - 0.000 - 0 - - 3.400 OK
STAIRCASE - 1.500 - 0.300 - 0.000 - 0 - - 3.400 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
24.00 mt. long 3.35 mt. High 3.60 mt. Wide Car Ramp - 3.58 - 3.35 - - - OK
12.00 mt. long 1.00 mt. High 3.40 mt. Wide Pedestrian Ramp 3.30 3.40 1.00 1.00 1.00 : 7.00 - 01 : 12 OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (BUILDING) BASEMENT FLOOR PLAN 2 2 OK
GROUND FLOOR PLAN - 1 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (BUILDING)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN PORTICO 2.50 2.50 4.60 4.60 - 11.48 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 7.76 - - 2.54 - - 3.05 - - 0.00 OK
Overhead WaterTank - - 15.49 - - 2.83 - - 5.47 - - 2.83 OK
ENT.GATE - - 2.07 - - 0.23 - - 9.00 - - 0.00 OK
ENT.GATE - - 2.07 - - 0.23 - - 9.00 - - 0.00 OK
GUARD ROOM - 10.00 4.48 - - 2.07 - - 2.17 - - 0.00 OK
GUARD ROOM - 10.00 4.55 - - 2.10 - - 2.17 - - 0.00 OK
SOLAR HEATING SYSTEM - - 6.71 - - 2.59 - - 2.59 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 5 OK
Entrance Gate 1 - 2 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Floor:TYPICAL - 1, 2, 3, 4 FLOOR PLAN



No Room Found.

[-] Floor:FIFTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 4301.75 OK
  Plot Width - 84.40 OK
  Plot Depth - 50.97 OK
  Access Width 9.00 15.00 OK
  Plot Frontage - 80.48 OK
  Coverage Area 2150.88 1400.79 OK
  FAR Area
Bldg. FAR Area : 8313.80
Sanctioned FAR Area :0.00
8603.50 8313.80 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Consumed FAR (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 19.25-23.10 mt.,Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For new area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) No rule found for Mini. reqd Floor height
(2) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number No Rule Defined
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) Lift lobby should be not free from FAR
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(6) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp (1) No rule Define.
(2) ; For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. (1) For parking spaces in basements and upper storey of parking floors, if car parking is more then 40 two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved and 5.4m width if one ramp is required shall be provided
(2) -
Arch Projection (1) No need to check
(2) Portico of upto 2.5m width,4.6m length & the reqd ht. 2.1m for bldg. 15m & above in height shall be permitted. {As per Rule No. 46.2}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building Overhead WaterTank
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bank No Rule Defined