Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
|
Plot Width |
The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
|
Plot Depth |
The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
|
Access Width |
The minimum width of abutting road for LPG Storage/Gas bottling Plant category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
|
Plot Frontage |
The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
|
FAR Area |
(1)
For Industrial buildings for polluting and hazardous industries, the Floor Area Ratio-FAR shall be 1.5 {As per Rule No. 39.5}
(2)
0.0
|
Consumed FAR |
(1)
For Industrial buildings for polluting and hazardous industries, the Floor Area Ratio-FAR shall be 1.5 {As per Rule No. 39.5}
(2)
0.0
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
;
(2)
;
(3)
; ;
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Parking DriveWay Check |
The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
|
Margin Rule |
(1)
For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
(2)
For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 45 mt. or above, Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 3.66 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
(3)
For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
(4)
For Hazardous occupancies, Margin required in Front shall be 12.0 mt., Rear 9.0 mt. and 9.0 mt. shall be provided on both side. {As per Rule No. 38.2.7}
|
PWork to PWork Margin |
Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
|
Building Level |
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
(4)
No rule found for Mini. reqd Floor height
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Floor Number |
No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4)
No need to check distance from Building RAIN WATER HARVESTING
(5)
No need to check distance from Building ENT.GATE
(6)
Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7)
No need to check distance from Building GUARD ROOM
(8)
Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9)
No need to check distance from Building Entrance Lobby
(10)
-
(11)
No need to check distance from Building SOLAR HEATING SYSTEM
(12)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13)
No need to check distance from Building Generator Room
(14)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(15)
No need to check distance from Building FIRE WATER PUMP HOUSE
|
Accessory Use Number |
(1)
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |