-
No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 08-07-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0007/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKonra
Taluka0
Architect Details
Architect NameNikhil Jain
License No.JIADA/ARC/0001/2018
Architect AddressBothra Bhawan, Opposite Indra Place, Main Road, Hinoo
Architect EmailIDbdpranchi@gmail.com
Architect Mobile No8087667001
Plot Details
Plot Use Hazardous
Plot SubUse Gas Bottling Plant
PlotNearbyReligiousStructure NA
Plot/SubPlot NoIndustrial Plot No. 13B, Barhi Industrial Area
NorthSurvey No. - 1534
SouthRoad Width - 60 (NH 2)
EastPlot No. - 1534
WestSurvey No. - 800,801,802,803
Owner's Details
NameMr Pranay Kumar
AddressDGM, Jamshedpur LPG Regional Office, HPCL, Large Sector, Adityapur Industrial Area, Gamharia, District - Saraikela Kharsawan, Jharkhand - 832402
Email IDMDTAUSIF.ANWAR@HPCL.IN
Mobile No9810141726
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 104166.00
2 Plot area as per Document by Applicant 104166.00
3 Physical area measured at site 104166.00
4 Area as per Site Visit (Site Visit Report) 103694.00
5Area as per Drawing 101836.55

Area of Plot Considered : 101836.55

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyHazardous
Plot SubUse Gas Bottling Plant
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 101836.55
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 101836.55
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 84220.57
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17615.98
17615.98
Balance Plot Area 84220.57

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 50918.27
Proposed Coverage Area ( 10.76 % ) 10954.27
Total Prop. Coverage Area ( 10.76 % ) 10954.27
Balance coverage area ( 39.24 % ) 39964.00
FAR CHECK
Perm. FAR Area ( 1.50 ) 152754.81
Total Perm. FAR area 152754.81
Residential FAR 562.07
Commercial FAR 245.46
Special FAR 10069.18
Proposed FAR Area 10876.71
Total Proposed FAR Area 10876.71
Consumed FAR (Factor) 0.11
Balance FAR Area 141878.10
BUA CHECK
Total Proposed BuiltUp Area 10954.26


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 60.97 60.97
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 103694 101836.55
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 5091.83 17615.98 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 343.13 No Access Provided OK
Normal Open Space - 624.93 No Access Provided OK
Normal Open Space - 833.80 No Access Provided OK
Normal Open Space - 1157.20 No Access Provided OK
Normal Open Space - 1234.72 No Access Provided OK
Normal Open Space - 1486.15 No Access Provided OK
Normal Open Space - 1984.85 No Access Provided OK
Normal Open Space - 4950.56 No Access Provided OK
Normal Open Space - 5000.64 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 18 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
ADMIN (ADMIN CONTROL) Commercial Shop Non-Highrise
D (DRIVER REST ROOM) Residential Residential Bldg/Apartment Non-Highrise
F (FIRE WATER PUMP HOUSE) Public Utility Public Utility Bldg Non-Highrise
G (GATE CABIN2) Residential Residential Bldg/Apartment Non-Highrise
INVOICE ROOM (INVOICE ROOM) Hazardous Gas Bottling Plant Non-Highrise
W (WEIGH BRIDGE) Hazardous Gas Bottling Plant Non-Highrise
L (LPG PUMP) Hazardous Gas Bottling Plant Non-Highrise
W (WARE HOUSE) Hazardous Gas Bottling Plant Non-Highrise
M (MCC ROOM) Hazardous Gas Bottling Plant Non-Highrise
W (WORKER AMENITIES) Residential Residential Bldg/Apartment Non-Highrise
P (PRESSURE TESTING SHED) Hazardous Gas Bottling Plant Non-Highrise
V (VALVE CHANGING SHED) Hazardous Gas Bottling Plant Non-Highrise
E (EMPTY CYLINDER) Hazardous Gas Bottling Plant Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
ADMIN (ADMIN CONTROL) 4.26 4.26 OK
D (DRIVER REST ROOM) 3.60 3.60 OK
F (FIRE WATER PUMP HOUSE) 5.18 OK
G (GATE CABIN2) 3.19 3.19 OK
INVOICE ROOM (INVOICE ROOM) 4.00 4.00 OK
W (WEIGH BRIDGE) 3.15 3.15 OK
L (LPG PUMP) 9.24 9.24 OK
W (WARE HOUSE) 6.44 6.44 OK
M (MCC ROOM) 5.20 5.20 OK
W (WORKER AMENITIES) 3.19 3.19 OK
P (PRESSURE TESTING SHED) 7.62 7.62 OK
V (VALVE CHANGING SHED) 7.66 7.66 OK
E (EMPTY CYLINDER) 9.56 9.56 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
ADMIN (ADMIN CONTROL) Ground Floor 2.75 - 4.26 2.75 - 4.11 2.40 - 3.88 OK
Plinth 0.45 - 0.75 - - 0.75 - - 0.75 OK
D (DRIVER REST ROOM) Ground Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.23 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
F (FIRE WATER PUMP HOUSE) Ground Floor 2.75 - 5.18 2.75 - 5.03 2.40 - 4.81 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
G (GATE CABIN2) Ground Floor 2.75 - 3.19 2.75 - 3.04 2.40 - 2.82 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
INVOICE ROOM (INVOICE ROOM) Ground Floor 2.75 - 4.00 2.75 - 3.85 2.40 - 3.63 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
W (WEIGH BRIDGE) Ground Floor 2.75 - 3.15 2.75 - 3.00 2.40 - 2.78 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
L (LPG PUMP) Ground Floor 2.75 - 9.24 2.75 - 9.09 2.40 - 9.00 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
W (WARE HOUSE) Ground Floor 2.75 - 6.44 2.75 - 6.29 2.40 - 6.07 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
M (MCC ROOM) Ground Floor 2.75 - 5.20 2.75 - 5.05 2.40 - 4.96 OK
Plinth 0.45 - 0.75 - - 0.75 - - 0.75 OK
W (WORKER AMENITIES) Ground Floor 2.75 - 3.19 2.75 - 3.04 2.40 - 2.82 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
P (PRESSURE TESTING SHED) Ground Floor 2.75 - 7.62 2.75 - 7.47 2.40 - 7.24 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
V (VALVE CHANGING SHED) Ground Floor 2.75 - 7.66 2.75 - 7.51 2.40 - 7.29 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
E (EMPTY CYLINDER) Ground Floor 2.75 - 9.56 2.75 - 9.41 2.40 - 9.18 OK
Plinth 0.45 - 0.75 - - 0.75 - - 0.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
ADMIN (ADMIN CONTROL) Terrace Floor 1.00 1.20 1.00 OK
D (DRIVER REST ROOM) Terrace Floor 1.00 1.20 1.00 OK
F (FIRE WATER PUMP HOUSE) Terrace Floor 1.00 1.20 1.13 OK
G (GATE CABIN2) Terrace Floor 1.00 1.20 1.00 OK
INVOICE ROOM (INVOICE ROOM) Terrace Floor 1.00 1.20 1.00 OK
W (WEIGH BRIDGE) Terrace Floor 1.00 1.20 1.00 OK
L (LPG PUMP) Terrace Floor 1.00 1.20 1.00 OK
W (WARE HOUSE) Terrace Floor 1.00 1.20 1.20 OK
M (MCC ROOM) Terrace Floor 1.00 1.20 1.00 OK
W (WORKER AMENITIES) Terrace Floor 1.00 1.20 1.00 OK
P (PRESSURE TESTING SHED) Terrace Floor 1.00 1.20 1.20 OK
V (VALVE CHANGING SHED) Terrace Floor 1.00 1.20 1.15 OK
E (EMPTY CYLINDER) Terrace Floor 1.00 1.20 1.20 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
ADMIN (ADMIN CONTROL) - 1 - 1 OK
D (DRIVER REST ROOM) - 1 - 1 OK
F (FIRE WATER PUMP HOUSE) - 1 - 1 OK
G (GATE CABIN2) - 1 - 0 OK
INVOICE ROOM (INVOICE ROOM) - 1 - 1 OK
W (WEIGH BRIDGE) - 1 - 1 OK
L (LPG PUMP) - 1 - 1 OK
W (WARE HOUSE) - 1 - 1 OK
M (MCC ROOM) - 1 - 1 OK
W (WORKER AMENITIES) - 1 - 1 OK
P (PRESSURE TESTING SHED) - 1 - 1 OK
V (VALVE CHANGING SHED) - 1 - 1 OK
E (EMPTY CYLINDER) - 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
50918.27 10954.27 OK
50% 10.76%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  ADMIN-1 (ADMIN CONTROL) - 323.02
  D-1 (DRIVER REST ROOM) - 227.52
  F-1 (FIRE WATER PUMP HOUSE) - 320.25
  G-1 (GATE CABIN2) - 45.76
  INVOICE ROOM-1 (INVOICE ROOM) - 186.97
  W-1 (WEIGH BRIDGE) - 15.78
  L-1 (LPG PUMP) - 216.24
  W-1 (WARE HOUSE) - 309.25
  M-1 (MCC ROOM) - 463.00
  W-1 (WORKER AMENITIES) - 288.79
  P-1 (PRESSURE TESTING SHED) - 1045.45
  V-1 (VALVE CHANGING SHED) - 787.92
  E-1 (EMPTY CYLINDER) - 6724.31
  Total Prop. Coverage Area - 10954.27
  Total Coverage Area 50918.27 10954.27

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.) Carpet Area other than Tenement
Accessory Use Resi. Commercial Public Utility Hazardous
ADMIN (ADMIN CONTROL) 1 323.02 77.56 0.00 245.46 0.00 0.00 245.46 245.46 01 0.00
D (DRIVER REST ROOM) 1 227.52 0.00 227.52 0.00 0.00 0.00 227.52 227.52 01 0.00
F (FIRE WATER PUMP HOUSE) 1 320.25 0.00 0.00 0.00 320.25 0.00 320.25 320.25 01 0.00
G (GATE CABIN2) 1 45.76 0.00 45.76 0.00 0.00 0.00 45.76 45.76 00 41.53
INVOICE ROOM (INVOICE ROOM) 1 186.97 0.00 0.00 0.00 0.00 186.97 186.97 186.97 01 0.00
W (WEIGH BRIDGE) 1 15.78 0.00 0.00 0.00 0.00 15.78 15.78 15.78 01 0.00
L (LPG PUMP) 1 216.24 0.00 0.00 0.00 0.00 216.24 216.24 216.24 01 0.00
W (WARE HOUSE) 1 309.25 0.00 0.00 0.00 0.00 309.25 309.25 309.25 01 0.00
M (MCC ROOM) 1 463.00 0.00 0.00 0.00 0.00 463.00 463.00 463.00 01 0.00
W (WORKER AMENITIES) 1 288.79 0.00 288.79 0.00 0.00 0.00 288.79 288.79 01 0.00
P (PRESSURE TESTING SHED) 1 1045.45 0.00 0.00 0.00 0.00 1045.45 1045.45 1045.45 01 0.00
V (VALVE CHANGING SHED) 1 787.92 0.00 0.00 0.00 0.00 787.92 787.92 787.92 01 0.00
E (EMPTY CYLINDER) 1 6724.31 0.00 0.00 0.00 0.00 6724.31 6724.31 6724.31 01 0.00
Grand Total : 13 10954.26 77.56 562.07 245.46 320.25 9748.93 10876.70 10876.70 12 41.53


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
ADMIN (ADMIN CONTROL) D (DRIVER REST ROOM) F (FIRE WATER PUMP HOUSE) G (GATE CABIN2) INVOICE ROOM (INVOICE ROOM) W (WEIGH BRIDGE) L (LPG PUMP) W (WARE HOUSE) M (MCC ROOM) W (WORKER AMENITIES) P (PRESSURE TESTING SHED) V (VALVE CHANGING SHED) E (EMPTY CYLINDER)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 323.02 245.46 227.52 227.52 320.25 320.25 45.76 45.76 186.97 186.97 15.78 15.78 216.24 216.24 309.25 309.25 463.00 463.00 288.79 288.79 1045.45 1045.45 787.92 787.92 6724.31 6724.31 10954.26 10876.70
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 323.02 245.46 227.52 227.52 320.25 320.25 45.76 45.76 186.97 186.97 15.78 15.78 216.24 216.24 309.25 309.25 463.00 463.00 288.79 288.79 1045.45 1045.45 787.92 787.92 6724.31 6724.31 10954.26 10876.70


[-] UnitBUA Table for Building :ADMIN (ADMIN CONTROL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN ADMIN BLOCK OFFICE 305.08 294.84 14 1
Total: - - 305.08 294.84 14 1
[-] UnitBUA Table for Building :D (DRIVER REST ROOM) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN DRIVER REST ROOM DWELLING UNIT 227.52 200.61 13 1
Total: - - 227.52 200.61 13 1
[-] UnitBUA Table for Building :F (FIRE WATER PUMP HOUSE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHED Public Utility Area 320.25 300.00 1 1
Total: - - 320.25 300.00 1 1
[-] UnitBUA Table for Building :INVOICE ROOM (INVOICE ROOM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN INVOICE ROOM OTHER 186.97 164.43 8 1
Total: - - 186.97 164.43 8 1
[-] UnitBUA Table for Building :W (WEIGH BRIDGE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SECURITY CABIN OTHER 15.78 12.49 1 1
Total: - - 15.78 12.49 1 1
[-] UnitBUA Table for Building :L (LPG PUMP)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN LPG PUMP HOUSE OTHER 216.24 202.19 1 1
Total: - - 216.24 202.19 1 1
[-] UnitBUA Table for Building :W (WARE HOUSE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN WARE HOUSE OTHER 309.25 290.85 2 1
Total: - - 309.25 290.85 2 1
[-] UnitBUA Table for Building :M (MCC ROOM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN MCC ROOM OTHER 463.00 425.47 7 1
Total: - - 463.00 425.47 7 1
[-] UnitBUA Table for Building :W (WORKER AMENITIES)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN WORK AMENITIES DWELLING UNIT 288.79 254.00 24 1
Total: - - 288.79 254.00 24 1
[-] UnitBUA Table for Building :P (PRESSURE TESTING SHED)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN PRESSURE TESTING SHED OTHER 1045.45 1015.14 1 1
Total: - - 1045.45 1015.14 1 1
[-] UnitBUA Table for Building :V (VALVE CHANGING SHED)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN VALVE CHANGING SHED OTHER 787.92 762.22 1 1
Total: - - 787.92 762.22 1 1
[-] UnitBUA Table for Building :E (EMPTY CYLINDER)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN EMPTY CYLINDER SHED OTHER 6724.31 6654.28 9 1
Total: - - 6724.31 6654.28 9 1


[-] Building :ADMIN (ADMIN CONTROL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Commercial
Ground Floor 323.02 77.56 245.46 245.46 245.46 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 323.02 77.56 245.46 245.46 245.46 01
Total Number of Same Buildings : 1
Total : 323.02 77.56 245.46 245.46 245.46 01

[-] Building :D (DRIVER REST ROOM)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 227.52 227.52 227.52 227.52 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 227.52 227.52 227.52 227.52 01
Total Number of Same Buildings : 1
Total : 227.52 227.52 227.52 227.52 01

[-] Building :F (FIRE WATER PUMP HOUSE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Public Utility
Ground Floor 320.25 320.25 320.25 320.25 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 320.25 320.25 320.25 320.25 01
Total Number of Same Buildings : 1
Total : 320.25 320.25 320.25 320.25 01

[-] Building :G (GATE CABIN2)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Carpet Area other than Tenement
Resi.
Ground Floor 45.76 45.76 45.76 45.76 41.53
Terrace Floor 0.00 0.00 0.00 0.00 0.00
Total : 45.76 45.76 45.76 45.76 41.53
Total Number of Same Buildings : 1
Total : 45.76 45.76 45.76 45.76 42

[-] Building :INVOICE ROOM (INVOICE ROOM)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 186.97 186.97 186.97 186.97 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 186.97 186.97 186.97 186.97 01
Total Number of Same Buildings : 1
Total : 186.97 186.97 186.97 186.97 01

[-] Building :W (WEIGH BRIDGE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 15.78 15.78 15.78 15.78 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 15.78 15.78 15.78 15.78 01
Total Number of Same Buildings : 1
Total : 15.78 15.78 15.78 15.78 01

[-] Building :L (LPG PUMP)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 216.24 216.24 216.24 216.24 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 216.24 216.24 216.24 216.24 01
Total Number of Same Buildings : 1
Total : 216.24 216.24 216.24 216.24 01

[-] Building :W (WARE HOUSE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 309.25 309.25 309.25 309.25 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 309.25 309.25 309.25 309.25 01
Total Number of Same Buildings : 1
Total : 309.25 309.25 309.25 309.25 01

[-] Building :M (MCC ROOM)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 463.00 463.00 463.00 463.00 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 463.00 463.00 463.00 463.00 01
Total Number of Same Buildings : 1
Total : 463.00 463.00 463.00 463.00 01

[-] Building :W (WORKER AMENITIES)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 288.79 288.79 288.79 288.79 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 288.79 288.79 288.79 288.79 01
Total Number of Same Buildings : 1
Total : 288.79 288.79 288.79 288.79 01

[-] Building :P (PRESSURE TESTING SHED)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 1045.45 1045.45 1045.45 1045.45 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 1045.45 1045.45 1045.45 1045.45 01
Total Number of Same Buildings : 1
Total : 1045.45 1045.45 1045.45 1045.45 01

[-] Building :V (VALVE CHANGING SHED)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 787.92 787.92 787.92 787.92 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 787.92 787.92 787.92 787.92 01
Total Number of Same Buildings : 1
Total : 787.92 787.92 787.92 787.92 01

[-] Building :E (EMPTY CYLINDER)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Hazardous
Ground Floor 6724.31 6724.31 6724.31 6724.31 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 6724.31 6724.31 6724.31 6724.31 01
Total Number of Same Buildings : 1
Total : 6724.31 6724.31 6724.31 6724.31 01
[-] Table 4c-2

  FAR Area
Building FAR Area:10876.71
Existing FAR Area :0.00
Perm.
152754.81
Prop.
10876.71
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
ADMIN-1 (ADMIN CONTROL) 60.97 M ROAD 9.00 152.13 6.00 234.14 6.00 150.37 6.00 54.64 OK
D-1 (DRIVER REST ROOM) 60.97 M ROAD 4.00 88.61 4.00 252.55 3.66 109.93 3.66 37.92 OK
E-1 (EMPTY CYLINDER) 60.97 M ROAD 12.00 215.69 9.00 105.23 9.00 36.89 9.00 21.04 OK
F-1 (FIRE WATER PUMP HOUSE) 60.97 M ROAD 6.50 190.30 4.50 246.36 4.50 170.99 4.50 30.84 OK
G-1 (GATE CABIN2) 60.97 M ROAD 4.00 111.62 4.00 272.43 3.66 147.60 3.66 30.72 OK
INVOICE ROOM-1 (INVOICE ROOM) 60.97 M ROAD 12.00 136.79 9.00 225.07 9.00 135.87 9.00 62.50 OK
L-1 (LPG PUMP) 60.97 M ROAD 12.00 364.24 9.00 31.47 9.00 76.08 9.00 126.66 OK
M-1 (MCC ROOM) 60.97 M ROAD 12.00 199.23 9.00 211.40 9.00 136.00 9.00 58.63 OK
P-1 (PRESSURE TESTING SHED) 60.97 M ROAD 12.00 347.48 9.00 82.35 9.00 108.80 9.00 44.40 OK
V-1 (VALVE CHANGING SHED) 60.97 M ROAD 12.00 298.62 9.00 85.05 9.00 32.33 9.00 131.09 OK
W-1 (WARE HOUSE) 60.97 M ROAD 12.00 239.10 9.00 233.23 9.00 161.00 9.00 12.15 OK
W-1 (WEIGH BRIDGE) 60.97 M ROAD 12.00 124.05 9.00 231.51 9.00 108.15 9.00 77.47 OK
W-1 (WORKER AMENITIES) 60.97 M ROAD 4.00 127.38 4.00 275.21 3.66 167.33 3.66 23.24 OK



[-] Building To Building Margin Check (Table 5b)
From Wing To Wing Margin Status
Reqd Prop
ADMIN-1 (ADMIN CONTROL) INVOICE ROOM-1 (INVOICE ROOM) 13.50 14.43 OK
V-1 (VALVE CHANGING SHED) 13.50 157.75 OK
D-1 (DRIVER REST ROOM) 13.50 51.96 OK
G-1 (GATE CABIN2) 13.50 30.88 OK
M-1 (MCC ROOM) 13.50 21.97 OK
P-1 (PRESSURE TESTING SHED) 13.50 175.31 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 24.28 OK
E-1 (EMPTY CYLINDER) 13.50 85.73 OK
L-1 (LPG PUMP) 13.50 218.58 OK
W-1 (WARE HOUSE) 13.50 65.95 OK
W-1 (WEIGH BRIDGE) 13.50 50.95 OK
W-1 (WORKER AMENITIES) 13.50 20.21 OK
D-1 (DRIVER REST ROOM) INVOICE ROOM-1 (INVOICE ROOM) 13.50 27.47 OK
V-1 (VALVE CHANGING SHED) 13.50 196.72 OK
ADMIN-1 (ADMIN CONTROL) 13.50 51.96 OK
G-1 (GATE CABIN2) 13.50 24.54 OK
M-1 (MCC ROOM) 13.50 90.04 OK
P-1 (PRESSURE TESTING SHED) 13.50 234.26 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 91.52 OK
E-1 (EMPTY CYLINDER) 13.50 115.48 OK
L-1 (LPG PUMP) 13.50 262.88 OK
W-1 (WARE HOUSE) 13.50 136.98 OK
W-1 (WEIGH BRIDGE) 13.50 16.93 OK
W-1 (WORKER AMENITIES) 13.50 44.86 OK
F-1 (FIRE WATER PUMP HOUSE) INVOICE ROOM-1 (INVOICE ROOM) 13.50 54.94 OK
V-1 (VALVE CHANGING SHED) 13.50 155.63 OK
ADMIN-1 (ADMIN CONTROL) 13.50 24.28 OK
D-1 (DRIVER REST ROOM) 13.50 91.52 OK
G-1 (GATE CABIN2) 13.50 69.97 OK
M-1 (MCC ROOM) 13.50 16.71 OK
P-1 (PRESSURE TESTING SHED) 13.50 157.15 OK
E-1 (EMPTY CYLINDER) 13.50 61.68 OK
L-1 (LPG PUMP) 13.50 214.14 OK
W-1 (WARE HOUSE) 13.50 21.76 OK
W-1 (WEIGH BRIDGE) 13.50 91.45 OK
W-1 (WORKER AMENITIES) 13.50 38.85 OK
G-1 (GATE CABIN2) INVOICE ROOM-1 (INVOICE ROOM) 13.50 24.18 OK
V-1 (VALVE CHANGING SHED) 13.50 205.20 OK
ADMIN-1 (ADMIN CONTROL) 13.50 30.88 OK
D-1 (DRIVER REST ROOM) 13.50 24.54 OK
M-1 (MCC ROOM) 13.50 78.80 OK
P-1 (PRESSURE TESTING SHED) 13.50 231.18 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 69.97 OK
E-1 (EMPTY CYLINDER) 13.50 130.12 OK
L-1 (LPG PUMP) 13.50 269.24 OK
W-1 (WARE HOUSE) 13.50 118.46 OK
W-1 (WEIGH BRIDGE) 13.50 42.80 OK
W-1 (WORKER AMENITIES) 13.50 15.28 OK
INVOICE ROOM-1 (INVOICE ROOM) V-1 (VALVE CHANGING SHED) 13.50 156.71 OK
ADMIN-1 (ADMIN CONTROL) 13.50 14.43 OK
D-1 (DRIVER REST ROOM) 13.50 27.47 OK
G-1 (GATE CABIN2) 13.50 24.18 OK
M-1 (MCC ROOM) 13.50 44.53 OK
P-1 (PRESSURE TESTING SHED) 13.50 187.39 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 54.94 OK
E-1 (EMPTY CYLINDER) 13.50 81.74 OK
L-1 (LPG PUMP) 13.50 221.26 OK
W-1 (WARE HOUSE) 13.50 94.46 OK
W-1 (WEIGH BRIDGE) 13.50 28.28 OK
W-1 (WORKER AMENITIES) 13.50 26.73 OK
W-1 (WEIGH BRIDGE) INVOICE ROOM-1 (INVOICE ROOM) 13.50 28.28 OK
V-1 (VALVE CHANGING SHED) 13.50 176.94 OK
ADMIN-1 (ADMIN CONTROL) 13.50 50.95 OK
D-1 (DRIVER REST ROOM) 13.50 16.93 OK
G-1 (GATE CABIN2) 13.50 42.80 OK
M-1 (MCC ROOM) 13.50 82.36 OK
P-1 (PRESSURE TESTING SHED) 13.50 217.89 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 91.45 OK
E-1 (EMPTY CYLINDER) 13.50 94.86 OK
L-1 (LPG PUMP) 13.50 243.38 OK
W-1 (WARE HOUSE) 13.50 132.28 OK
W-1 (WORKER AMENITIES) 13.50 57.33 OK
L-1 (LPG PUMP) INVOICE ROOM-1 (INVOICE ROOM) 13.50 221.26 OK
V-1 (VALVE CHANGING SHED) 13.50 32.80 OK
ADMIN-1 (ADMIN CONTROL) 13.50 218.58 OK
D-1 (DRIVER REST ROOM) 13.50 262.88 OK
G-1 (GATE CABIN2) 13.50 269.24 OK
M-1 (MCC ROOM) 13.50 181.60 OK
P-1 (PRESSURE TESTING SHED) 13.50 47.26 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 214.14 OK
E-1 (EMPTY CYLINDER) 13.50 89.63 OK
W-1 (WARE HOUSE) 13.50 184.40 OK
W-1 (WEIGH BRIDGE) 13.50 243.38 OK
W-1 (WORKER AMENITIES) 13.50 260.96 OK
W-1 (WARE HOUSE) INVOICE ROOM-1 (INVOICE ROOM) 13.50 94.46 OK
V-1 (VALVE CHANGING SHED) 13.50 128.82 OK
ADMIN-1 (ADMIN CONTROL) 13.50 65.95 OK
D-1 (DRIVER REST ROOM) 13.50 136.98 OK
G-1 (GATE CABIN2) 13.50 118.46 OK
M-1 (MCC ROOM) 13.50 21.38 OK
P-1 (PRESSURE TESTING SHED) 13.50 124.87 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 21.76 OK
E-1 (EMPTY CYLINDER) 13.50 25.38 OK
L-1 (LPG PUMP) 13.50 184.40 OK
W-1 (WEIGH BRIDGE) 13.50 132.28 OK
W-1 (WORKER AMENITIES) 13.50 85.53 OK
M-1 (MCC ROOM) INVOICE ROOM-1 (INVOICE ROOM) 13.50 44.53 OK
V-1 (VALVE CHANGING SHED) 13.50 123.09 OK
ADMIN-1 (ADMIN CONTROL) 13.50 21.97 OK
D-1 (DRIVER REST ROOM) 13.50 90.04 OK
G-1 (GATE CABIN2) 13.50 78.80 OK
P-1 (PRESSURE TESTING SHED) 13.50 128.23 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 16.71 OK
E-1 (EMPTY CYLINDER) 13.50 46.21 OK
L-1 (LPG PUMP) 13.50 181.60 OK
W-1 (WARE HOUSE) 13.50 21.38 OK
W-1 (WEIGH BRIDGE) 13.50 82.36 OK
W-1 (WORKER AMENITIES) 13.50 62.52 OK
W-1 (WORKER AMENITIES) INVOICE ROOM-1 (INVOICE ROOM) 13.50 26.73 OK
V-1 (VALVE CHANGING SHED) 13.50 201.29 OK
ADMIN-1 (ADMIN CONTROL) 13.50 20.21 OK
D-1 (DRIVER REST ROOM) 13.50 44.86 OK
G-1 (GATE CABIN2) 13.50 15.28 OK
M-1 (MCC ROOM) 13.50 62.52 OK
P-1 (PRESSURE TESTING SHED) 13.50 212.72 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 38.85 OK
E-1 (EMPTY CYLINDER) 13.50 124.99 OK
L-1 (LPG PUMP) 13.50 260.96 OK
W-1 (WARE HOUSE) 13.50 85.53 OK
W-1 (WEIGH BRIDGE) 13.50 57.33 OK
P-1 (PRESSURE TESTING SHED) INVOICE ROOM-1 (INVOICE ROOM) 13.50 187.39 OK
V-1 (VALVE CHANGING SHED) 13.50 46.24 OK
ADMIN-1 (ADMIN CONTROL) 13.50 175.31 OK
D-1 (DRIVER REST ROOM) 13.50 234.26 OK
G-1 (GATE CABIN2) 13.50 231.18 OK
M-1 (MCC ROOM) 13.50 128.23 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 157.15 OK
E-1 (EMPTY CYLINDER) 13.50 31.30 OK
L-1 (LPG PUMP) 13.50 47.26 OK
W-1 (WARE HOUSE) 13.50 124.87 OK
W-1 (WEIGH BRIDGE) 13.50 217.89 OK
W-1 (WORKER AMENITIES) 13.50 212.72 OK
V-1 (VALVE CHANGING SHED) INVOICE ROOM-1 (INVOICE ROOM) 13.50 156.71 OK
ADMIN-1 (ADMIN CONTROL) 13.50 157.75 OK
D-1 (DRIVER REST ROOM) 13.50 196.72 OK
G-1 (GATE CABIN2) 13.50 205.20 OK
M-1 (MCC ROOM) 13.50 123.09 OK
P-1 (PRESSURE TESTING SHED) 13.50 46.24 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 155.63 OK
E-1 (EMPTY CYLINDER) 13.50 31.12 OK
L-1 (LPG PUMP) 13.50 32.80 OK
W-1 (WARE HOUSE) 13.50 128.82 OK
W-1 (WEIGH BRIDGE) 13.50 176.94 OK
W-1 (WORKER AMENITIES) 13.50 201.29 OK
E-1 (EMPTY CYLINDER) INVOICE ROOM-1 (INVOICE ROOM) 13.50 81.74 OK
V-1 (VALVE CHANGING SHED) 13.50 31.12 OK
ADMIN-1 (ADMIN CONTROL) 13.50 85.73 OK
D-1 (DRIVER REST ROOM) 13.50 115.48 OK
G-1 (GATE CABIN2) 13.50 130.12 OK
M-1 (MCC ROOM) 13.50 46.21 OK
P-1 (PRESSURE TESTING SHED) 13.50 31.30 OK
F-1 (FIRE WATER PUMP HOUSE) 13.50 61.68 OK
L-1 (LPG PUMP) 13.50 89.63 OK
W-1 (WARE HOUSE) 13.50 25.38 OK
W-1 (WEIGH BRIDGE) 13.50 94.86 OK
W-1 (WORKER AMENITIES) 13.50 124.99 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: D (DRIVER REST ROOM)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: G (GATE CABIN2)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: W (WORKER AMENITIES)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler Loading/Unloading/Truck/Bus
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
ADMIN (ADMIN CONTROL) Commercial Shop > 0 50 245.46 1 4 - - - - - - -
> 0 50 245.46 - - - 1 11 - - - -
F (FIRE WATER PUMP HOUSE) Public Utility Public Utility Bldg > 0 300 320.25 1 1 - - - - - - -
> 0 300 320.25 - - - 1 3 - - - -
INVOICE ROOM (INVOICE ROOM) Hazardous Gas Bottling Plant > 0 400 186.97 1 1 - - - - - - -
> 0 400 186.97 - - - 1 1 - - - -
W (WEIGH BRIDGE) Hazardous Gas Bottling Plant > 0 400 15.78 1 1 - - - - - - -
> 0 400 15.78 - - - 1 1 - - - -
L (LPG PUMP) Hazardous Gas Bottling Plant > 0 400 216.24 1 1 - - - - - - -
> 0 400 216.24 - - - 1 2 - - - -
W (WARE HOUSE) Hazardous Gas Bottling Plant > 0 400 309.25 1 1 - - - - - - -
> 0 400 309.25 - - - 1 2 - - - -
M (MCC ROOM) Hazardous Gas Bottling Plant > 0 400 463.00 1 1 - - - - - - -
> 0 400 463.00 - - - 1 3 - - - -
P (PRESSURE TESTING SHED) Hazardous Gas Bottling Plant > 0 400 1045.45 1 2 - - - - - - -
> 0 400 1045.45 - - - 1 6 - - - -
V (VALVE CHANGING SHED) Hazardous Gas Bottling Plant > 0 400 787.92 1 2 - - - - - - -
> 0 400 787.92 - - - 1 5 - - - -
E (EMPTY CYLINDER) Hazardous Gas Bottling Plant > 0 400 6724.31 1 12 - - - - - - -
> 0 400 6724.31 - - - 1 36 - - - -
Total : - - - - 26 28 - 70 70 - 0 62

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 28 350.00 OK
Total Car 26 325.00 28 350.00 OK
Loading/Unloading - - 62 1627.50 OK
TwoWheeler - - 70 140.00 OK
Total TwoWheeler 70 140.00 70 140.00 OK
Total 465.00 2257.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 4.00 - - 2.00 - - 2.00 - - 0.00 OK
RAIN WATER HARVESTING - - 81.55 - - 7.70 - - 10.60 - - 0.00 OK
ENT.GATE - - 4.81 - - 3.66 - - 10.26 - - 0.00 OK
GUARD ROOM - 10.00 4.00 - - 2.00 - - 2.00 - - 0.00 OK
Entrance Lobby - 12.00 10.18 - - 2.70 - - 3.77 - - 0.00 OK
Entrance Lobby - 12.00 10.18 - - 2.70 - - 3.77 - - 0.00 OK
Entrance Lobby - 12.00 9.36 - - 2.48 - - 3.77 - - 0.00 OK
Entrance Lobby - 12.00 8.50 - - 2.09 - - 4.06 - - 0.00 OK
Entrance Lobby - 12.00 10.30 - - 2.40 - - 4.29 - - 0.00 OK
Entrance Lobby - 12.00 10.71 - - 2.00 - - 5.35 - - 0.00 OK
Entrance Lobby - 12.00 10.71 - - 2.00 - - 5.35 - - 0.00 OK
Entrance Lobby - 12.00 7.62 - - 2.54 - - 4.27 - - 0.00 OK
SOLAR HEATING SYSTEM - - 23.74 - - 3.96 - - 5.99 - - 0.00 OK
SOLAR HEATING SYSTEM - - 18.74 - - 3.42 - - 5.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 9.01 - - 1.86 - - 4.85 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.10 - - 0.84 - - 2.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 8.05 - - 1.68 - - 4.79 - - 0.00 OK
SOLAR HEATING SYSTEM - - 8.05 - - 1.68 - - 4.79 - - 0.00 OK
SOLAR HEATING SYSTEM - - 8.05 - - 1.68 - - 4.79 - - 0.00 OK
Generator Room - - 53.09 - - 7.04 - - 7.54 - - 0.00 OK
FIRE WATER PUMP HOUSE - - 550.58 - - 26.49 - - 26.49 - - 0.00 OK
FIRE WATER PUMP HOUSE - - 379.47 - - 21.99 - - 22.00 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
ADMIN (ADMIN CONTROL) Rain Water Harvesting 1 - 1 OK
D (DRIVER REST ROOM) Rain Water Harvesting 1 - 1 OK
F (FIRE WATER PUMP HOUSE) Rain Water Harvesting 1 - 1 OK
G (GATE CABIN2) Rain Water Harvesting 1 - 1 OK
INVOICE ROOM (INVOICE ROOM) Rain Water Harvesting 1 - 1 OK
W (WEIGH BRIDGE) Rain Water Harvesting 1 - 1 OK
L (LPG PUMP) Rain Water Harvesting 1 - 1 OK
W (WARE HOUSE) Rain Water Harvesting 1 - 1 OK
M (MCC ROOM) Rain Water Harvesting 1 - 1 OK
W (WORKER AMENITIES) Rain Water Harvesting 1 - 1 OK
P (PRESSURE TESTING SHED) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
V (VALVE CHANGING SHED) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
E (EMPTY CYLINDER) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:ADMIN (ADMIN CONTROL)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:D (DRIVER REST ROOM)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:E (EMPTY CYLINDER)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:F (FIRE WATER PUMP HOUSE)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:G (GATE CABIN2)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Building:INVOICE ROOM (INVOICE ROOM)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:L (LPG PUMP)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:M (MCC ROOM)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:P (PRESSURE TESTING SHED)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:V (VALVE CHANGING SHED)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:W (WARE HOUSE)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:W (WEIGH BRIDGE)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:W (WORKER AMENITIES)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 500.00 101836.55 OK
  Plot Width - 233.82 OK
  Plot Depth - 435.54 OK
  Access Width 12.20 60.97 OK
  Plot Frontage - 99.11 OK
  Coverage Area 50918.27 10954.27 OK
  FAR Area
Bldg. FAR Area : 10876.71
Sanctioned FAR Area :0.00
152754.81 10876.71 OK




</

[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for LPG Storage/Gas bottling Plant category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for LPG Storage/Gas bottling Plant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
FAR Area (1) For Industrial buildings for polluting and hazardous industries, the Floor Area Ratio-FAR shall be 1.5 {As per Rule No. 39.5}
(2) 0.0
Consumed FAR (1) For Industrial buildings for polluting and hazardous industries, the Floor Area Ratio-FAR shall be 1.5 {As per Rule No. 39.5}
(2) 0.0
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule (1) For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
(2) For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 45 mt. or above, Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 3.66 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
(3) For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
(4) For Hazardous occupancies, Margin required in Front shall be 12.0 mt., Rear 9.0 mt. and 9.0 mt. shall be provided on both side. {As per Rule No. 38.2.7}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
(4) No rule found for Mini. reqd Floor height
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building Entrance Lobby
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
(14) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(15) No need to check distance from Building FIRE WATER PUMP HOUSE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)