No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.53  
Version Date: 16/10/2020 
Report Generated On: 07-01-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0012/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKonra
Taluka0
Architect Details
Architect NameNikhil Jain
License No.JIADA/ARC/0001/2018
Architect AddressBothra Bhawan, Opposite Indra Place, Main Road, Hinoo
Architect EmailIDbdpranchi@gmail.com
Architect Mobile No8087667001
Plot Details
Plot Use Industrial
Plot SubUse Industrial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No146P, 170P, 171P, 172P, 151P, 152P, 153P, 154P, 157P, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167P, 168, 169P, 530P
NorthSurvey No. - Survey Plot No. 146P,167P,151P,152P,153P,154P,157P,530P and Industrial Road
SouthSurvey No. - 177P,,232,231,244,245 and Industrial Boundary
EastSurvey No. - 530P and Industrial Plot No.57/C
WestSurvey No. - 146P,170P,171P,172P and Industrial Plot No.57/A
Owner's Details
NameSumit Garg
AddressPlot No. 57/B, Barhi Industrial Area, Village - Konra, P.O.- Barhi, District - Hazaribagh, Jharkhand
Email IDpavanputrasteel@gmail.com
Mobile No8797071224
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 22541.20
2 Plot area as per Document by Applicant 22540.90
3 Physical area measured at site 22540.90
4 Area as per Site Visit (Site Visit Report) 21834.00
5Area as per Drawing 21833.95

Area of Plot Considered : 21833.95

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyIndustrial
Plot SubUse Industrial Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 21833.95
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 21833.95
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 19081.77
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 2752.18
2752.18
Balance Plot Area 19081.77

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 10916.97
Proposed Coverage Area ( 17.46 % ) 3813.18
Accessory Use area at COP 99.38
Total Prop. Coverage Area ( 17.92 % ) 3912.56
Balance coverage area ( 32.08 % ) 7004.41
FAR CHECK
Perm. FAR Area ( 2.00 ) 43667.90
Total Perm. FAR area 43667.90
Residential FAR 367.30
Industrial FAR 3420.18
Proposed FAR Area 3787.47
Total Proposed FAR Area 3787.47
Consumed FAR (Factor) 0.17
Balance FAR Area 39880.43
BUA CHECK
Total Proposed BuiltUp Area 3813.17


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 21.34 21.34
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 21834 21833.95
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 2183.40 2752.18 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 1309.26 No Access Provided OK
Normal Open Space - 1442.92 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
S (SHED 1) Industrial Industrial Building Non-Highrise
A (ADMIN) Residential Other Residential Building Non-Highrise
C (CANTEEN) Residential Other Residential Building Non-Highrise
G (GUEST HOUSE) Residential Staff Quarters Non-Highrise
S (SHED 2) Industrial Industrial Building Non-Highrise
G (GUARD) Residential Other Residential Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
S (SHED 1) 7.66 7.66 OK
A (ADMIN) 3.44 3.44 OK
C (CANTEEN) 3.60 3.60 OK
G (GUEST HOUSE) 3.30 3.30 OK
S (SHED 2) 15.65 15.65 OK
G (GUARD) 3.00 3.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
S (SHED 1) Ground Floor 2.75 - 7.66 2.75 - 7.54 2.40 - 7.39 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK
A (ADMIN) Ground Floor 2.75 - 3.44 2.75 - 3.32 2.40 - 3.17 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK
C (CANTEEN) Ground Floor 2.75 - 3.60 2.75 - 3.48 2.40 - 3.33 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK
G (GUEST HOUSE) Ground Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 3.03 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK
S (SHED 2) Ground Floor 2.75 - 15.65 2.75 - 15.53 2.40 - 15.38 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK
G (GUARD) Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.73 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
S (SHED 1) Terrace Floor 1.00 1.20 1.20 OK
A (ADMIN) Terrace Floor 1.00 1.20 1.00 OK
C (CANTEEN) Terrace Floor 1.00 1.20 1.00 OK
G (GUEST HOUSE) Terrace Floor 1.00 1.20 1.00 OK
S (SHED 2) Terrace Floor 1.00 1.20 1.19 OK
G (GUARD) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
S (SHED 1) - 1 - 1 OK
A (ADMIN) - 1 - 1 OK
C (CANTEEN) - 1 - 1 OK
G (GUEST HOUSE) - 1 - 1 OK
S (SHED 2) - 1 - 1 OK
G (GUARD) - 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
10916.97 3912.56 OK
50% 17.92%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  S-1 (SHED 1) - 542.50
  A-1 (ADMIN) - 177.59
  C-1 (CANTEEN) - 121.35
  G-1 (GUEST HOUSE) - 81.78
  S-1 (SHED 2) - 2877.68
  G-1 (GUARD) - 12.27
  Total Prop. Coverage Area - 3813.18
  Accessory Use area - 99.38
  Total Coverage Area 10916.97 3912.56

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi. Industrial
S (SHED 1) 1 542.50 0.00 0.00 542.50 542.50 542.50 01
A (ADMIN) 1 177.59 25.70 151.89 0.00 151.89 151.89 01
C (CANTEEN) 1 121.35 0.00 121.35 0.00 121.35 121.35 01
G (GUEST HOUSE) 1 81.78 0.00 81.78 0.00 81.78 81.78 01
S (SHED 2) 1 2877.68 0.00 0.00 2877.68 2877.68 2877.68 01
G (GUARD) 1 12.27 0.00 12.27 0.00 12.27 12.27 01
Grand Total : 6 3813.17 25.70 367.29 3420.18 3787.47 3787.47 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
S (SHED 1) A (ADMIN) C (CANTEEN) G (GUEST HOUSE) S (SHED 2) G (GUARD)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 542.50 542.50 177.59 151.89 121.35 121.35 81.78 81.78 2877.68 2877.68 12.27 12.27 3813.17 3787.47
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 542.50 542.50 177.59 151.89 121.35 121.35 81.78 81.78 2877.68 2877.68 12.27 12.27 3813.17 3787.47


[-] UnitBUA Table for Building :S (SHED 1)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHED-1 OTHER 542.50 530.75 1 1
Total: - - 542.50 530.75 1 1
[-] UnitBUA Table for Building :A (ADMIN) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN ADMIN FLAT 168.08 158.67 8 1
Total: - - 168.08 158.67 8 1
[-] UnitBUA Table for Building :C (CANTEEN)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN CANTEEN FLAT 121.35 104.77 11 1
Total: - - 121.35 104.77 11 1
[-] UnitBUA Table for Building :G (GUEST HOUSE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GUEST HOUSE FLAT 81.78 70.09 6 1
Total: - - 81.78 70.09 6 1
[-] UnitBUA Table for Building :S (SHED 2)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHED-2 OTHER 2877.68 2840.59 1 1
Total: - - 2877.68 2840.59 1 1
[-] UnitBUA Table for Building :G (GUARD)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GUARD FLAT 12.27 9.02 1 1
Total: - - 12.27 9.02 1 1


[-] Building :S (SHED 1)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 542.50 542.50 542.50 542.50 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 542.50 542.50 542.50 542.50 01
Total Number of Same Buildings : 1
Total : 542.50 542.50 542.50 542.50 01

[-] Building :A (ADMIN)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi.
Ground Floor 177.59 25.70 151.89 151.89 151.89 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 177.59 25.70 151.89 151.89 151.89 01
Total Number of Same Buildings : 1
Total : 177.59 25.70 151.89 151.89 151.89 01

[-] Building :C (CANTEEN)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 121.35 121.35 121.35 121.35 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 121.35 121.35 121.35 121.35 01
Total Number of Same Buildings : 1
Total : 121.35 121.35 121.35 121.35 01

[-] Building :G (GUEST HOUSE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 81.78 81.78 81.78 81.78 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 81.78 81.78 81.78 81.78 01
Total Number of Same Buildings : 1
Total : 81.78 81.78 81.78 81.78 01

[-] Building :S (SHED 2)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 2877.68 2877.68 2877.68 2877.68 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 2877.68 2877.68 2877.68 2877.68 01
Total Number of Same Buildings : 1
Total : 2877.68 2877.68 2877.68 2877.68 01

[-] Building :G (GUARD)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 12.27 12.27 12.27 12.27 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 12.27 12.27 12.27 12.27 01
Total Number of Same Buildings : 1
Total : 12.27 12.27 12.27 12.27 01
[-] Table 4c-2

  FAR Area
Building FAR Area:3787.47
Existing FAR Area :0.00
Perm.
43667.90
Prop.
3787.47
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (ADMIN) 21.34 M ROAD 4.00 70.09 4.00 64.39 3.66 21.18 3.66 93.99 OK
C-1 (CANTEEN) 21.34 M ROAD 4.00 122.43 4.00 13.65 3.66 9.30 3.66 108.14 OK
G-1 (GUARD) 21.34 M ROAD 4.00 4.20 4.00 159.89 3.66 104.53 3.66 17.70 OK
G-1 (GUEST HOUSE) 21.34 M ROAD 4.00 15.24 4.00 126.93 3.66 18.47 3.66 97.89 OK
S-1 (SHED 1) 21.34 M ROAD 12.00 14.10 9.00 120.61 9.00 58.51 9.00 39.11 OK
S-1 (SHED 2) 21.34 M ROAD 12.00 50.98 9.00 14.75 9.00 74.60 9.00 16.73 OK



[-] Building To Building Margin Check (Table 5b)
From Wing To Wing Margin Status
Reqd Prop
S-1 (SHED 1) A-1 (ADMIN) 13.50 48.41 OK
G-1 (GUEST HOUSE) 13.50 30.62 OK
C-1 (CANTEEN) 13.50 102.52 OK
S-1 (SHED 2) 13.50 16.61 OK
G-1 (GUARD) 13.50 19.95 OK
A-1 (ADMIN) S-1 (SHED 1) 13.50 48.41 OK
G-1 (GUEST HOUSE) 13.50 46.40 OK
C-1 (CANTEEN) 13.50 38.09 OK
S-1 (SHED 2) 13.50 54.18 OK
G-1 (GUARD) 13.50 99.59 OK
C-1 (CANTEEN) A-1 (ADMIN) 13.50 38.09 OK
S-1 (SHED 1) 13.50 102.52 OK
G-1 (GUEST HOUSE) 13.50 100.01 OK
S-1 (SHED 2) 13.50 55.01 OK
G-1 (GUARD) 13.50 149.86 OK
G-1 (GUEST HOUSE) A-1 (ADMIN) 13.50 46.40 OK
S-1 (SHED 1) 13.50 30.62 OK
C-1 (CANTEEN) 13.50 100.01 OK
S-1 (SHED 2) 13.50 64.15 OK
G-1 (GUARD) 13.50 77.65 OK
S-1 (SHED 2) A-1 (ADMIN) 13.50 54.18 OK
S-1 (SHED 1) 13.50 16.61 OK
G-1 (GUEST HOUSE) 13.50 64.15 OK
C-1 (CANTEEN) 13.50 55.01 OK
G-1 (GUARD) 13.50 43.58 OK
G-1 (GUARD) A-1 (ADMIN) 13.50 99.59 OK
S-1 (SHED 1) 13.50 19.95 OK
G-1 (GUEST HOUSE) 13.50 77.65 OK
C-1 (CANTEEN) 13.50 149.86 OK
S-1 (SHED 2) 13.50 43.58 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Other Residential Building, In Building: A (ADMIN)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Other Residential Building, In Building: C (CANTEEN)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Staff Quarters, In Building: G (GUEST HOUSE)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Other Residential Building, In Building: G (GUARD)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
S (SHED 1) Industrial Industrial Building > 0 400 542.50 1 1 - - - - - - -
> 0 400 542.50 - - - - - - 1 3 -
S (SHED 2) Industrial Industrial Building > 0 400 2877.68 1 5 - - - - - - -
> 0 400 2877.68 - - - - - - 1 15 -
Total : - - - - 6 10 - 0 4 - 18 22

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 10 125.00 OK
Total Car 10 125.00 10 125.00 OK
Visitor's Car Parking - - 4 50.00 OK
Total Visitor Parking 4 50.00 4 50.00 OK
TwoWheeler - - 22 44.00 OK
Total TwoWheeler 21 42.00 22 44.00 OK
Total 217.00 263.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (ADMIN)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.275 0.225 0.250 0.200 0.132 - 13 - - 0.000 OK

No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


No Staircase Found


   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 2.41 - - 1.36 - - 1.82 - - 0.00 OK
RAIN WATER HARVESTING - - 47.69 - - 5.71 - - 8.35 - - 0.00 OK
ELECTRIC SUBSTATION - - 73.13 - - 4.20 - - 17.41 - - 0.00 OK
MCC ROOM - - 26.25 - - 3.50 - - 7.50 - - 0.00 OK
ENT.GATE - - 3.35 - - 0.72 - - 5.01 - - 0.00 OK
ENT.GATE - - 3.60 - - 0.75 - - 5.01 - - 0.00 OK
ETP - - 8.64 - - 2.40 - - 3.60 - - 0.00 OK
Under ground water tank - - 33.95 - - 3.50 - - 9.70 - - 0.00 OK
Entrance Lobby - 12.00 9.44 - - 2.25 - - 4.20 - - 0.00 OK
Entrance Lobby - 12.00 9.44 - - 2.25 - - 4.20 - - 0.00 OK
Entrance Lobby - 12.00 6.82 - - 2.25 - - 3.03 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.79 - - 0.51 - - 1.54 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
S (SHED 1) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 2 OK
A (ADMIN) Rain Water Harvesting 1 - 1 OK
C (CANTEEN) Rain Water Harvesting 1 - 1 OK
G (GUEST HOUSE) Rain Water Harvesting 1 - 1 OK
S (SHED 2) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 2 OK
G (GUARD) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (ADMIN)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Building:C (CANTEEN)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Building:G (GUARD)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:G (GUEST HOUSE)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Building:S (SHED 1)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:S (SHED 2)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 21833.95 OK
  Plot Width - 158.58 OK
  Plot Depth - 137.68 OK
  Access Width 9.00 21.34 OK
  Plot Frontage - 126.30 OK
  Coverage Area 10916.97 3912.56 OK
  FAR Area
Bldg. FAR Area : 3787.47
Sanctioned FAR Area :0.00
43667.90 3787.47 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Consumed FAR (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule (1) For Industrial Building having plotarea 5000-30000 sq.mt., Margin required in Front shall be 12.0 mt., Rear 9.0 mt. and 9.0 mt. shall be provided on both side. {As per Rule No. 36 Table 12}
(2) For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 45 mt. or above, Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 3.66 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Floor Height (1) No rule found for Mini. reqd Floor height
(2) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
(3) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(4) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number No Rule Defined
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(6) No need to check distance from Building ELECTRIC SUBSTATION
(7) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(8) No need to check distance from Building MCC ROOM
(9) No need to check distance from Building ENT.GATE
(10) -
(11) No need to check distance from Building ETP
(12) -
(13) No need to check distance from Building Under ground water tank
(14) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(15) No need to check distance from Building Entrance Lobby
(16) -
(17) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)