Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 05-08-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0007/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageDardag Chakla
Taluka0
Architect Details
Architect NameGANESHA SHETTY B
License No.JIADA/ARC/0003/2018
Architect Address274, CAUVERY, 4th Cross, 2nd Block, 2nd Stage, RMV
Architect EmailIDcauverysg274@gmail.com
Architect Mobile No9448002844
Plot Details
Plot Use Industrial
Plot SubUse Industrial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No2A
NorthRoad Width - 16
SouthSurvey No. - 882P, 892P, 893P, 895P, 927P & Indl. Plot No.2B
EastSurvey No. - 146P, 317P, 320P, 900P, 901P, 927P & Indl. Bounadry
WestSurvey No. - Survey Plot No. 143P, 317P, 318P, 882P, 899P, 897P & Indl. Plot No.1
Owner's Details
NameGautam Nair
AddressPlot No. 2A, Dardag Chakla Industrial Area Dardag Chakla Village, Ranchi
Email IDvipin.gupta@matrixclothing.in
Mobile No9810892606
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 24281.14
2 Physical area measured at site 24281.14
3 Area as per Site Visit (Site Visit Report) 24281.66
4Area as per Drawing 24263.37

Area of Plot Considered : 24263.37

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyIndustrial
Plot SubUse Industrial Building
Building StructureNon-Highrise
Building TypeNA
Gross Plot Area 24263.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 24263.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 20821.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 3441.76
3441.76
Balance Plot Area 20821.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 12131.68
Proposed Coverage Area ( 31.76 % ) 7705.48
Total Prop. Coverage Area ( 31.76 % ) 7705.48
Balance coverage area ( 18.24 % ) 4426.20
FAR CHECK
Perm. FAR Area ( 2.00 ) 48526.74
Total Perm. FAR area 48526.74
Industrial FAR 7813.26
Proposed FAR Area 7813.26
Total Proposed FAR Area 7813.26
Consumed FAR (Factor) 0.32
Balance FAR Area 40713.48
BUA CHECK
Total Proposed BuiltUp Area 7813.27


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 16 16.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 24281.66 24263.37


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 2426.34 3441.76 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 105.19 0.00 0.00 - 4.22 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 334.82 0.00 0.00 - 5.67 - 41.86 16 M WIDE SIKIDARI MAINROAD OK
Tree Cover (Plantation) - 384.59 0.00 0.00 - 5.87 - 89.53 No Access Provided OK
Tree Cover (Plantation) - 700.70 0.00 0.00 - 11.96 - 89.88 No Access Provided OK
Tree Cover (Plantation) - 783.21 0.00 0.00 - 3.63 - 89.63 No Access Provided OK
Tree Cover (Plantation) - 1133.27 0.00 0.00 - 5.31 - 84.12 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 17 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MAIN BUILDING) Industrial Industrial Building Non-Highrise
B (COMPRESSOR) Industrial Industrial Building Non-Highrise
C (CHEMICAL AND CHINDI) Industrial Industrial Building Non-Highrise
D (LT AND BOILER) Industrial Industrial Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MAIN BUILDING) 30.00 8.40 8.40 8.40 OK
B (COMPRESSOR) 30.00 7.86 7.86 7.86 OK
C (CHEMICAL AND CHINDI) 30.00 4.16 4.16 4.16 OK
D (LT AND BOILER) 30.00 7.19 7.19 7.19 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MAIN BUILDING) Ground Floor 2.75 - 8.40 2.75 - 6.55 2.40 - 6.55 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
B (COMPRESSOR) First Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.00 OK
Ground Floor 2.75 - 4.26 2.75 - 4.11 2.40 - 3.66 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
C (CHEMICAL AND CHINDI) Ground Floor 2.75 - 4.16 2.75 - 3.24 2.40 - 3.15 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK
D (LT AND BOILER) Ground Floor 2.75 - 7.19 2.75 - 6.44 2.40 - 6.23 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
B (COMPRESSOR) Terrace Floor - - 1.20 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MAIN BUILDING) - 1 - 5 OK
B (COMPRESSOR) - 2 - 2 OK
C (CHEMICAL AND CHINDI) - 1 - 1 OK
D (LT AND BOILER) - 1 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
12131.68 7705.48 OK
50% 31.76%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MAIN BUILDING) - 7204.86
  B-1 (COMPRESSOR) - 107.77
  C-1 (CHEMICAL AND CHINDI) - 117.00
  D-1 (LT AND BOILER) - 275.85
  Total Prop. Coverage Area - 7705.48
  Total Coverage Area 12131.68 7705.48

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
A (MAIN BUILDING) 1 7204.86 7204.86 7204.86 7204.86 05
B (COMPRESSOR) 1 215.56 215.55 215.56 215.56 02
C (CHEMICAL AND CHINDI) 1 117.00 117.00 117.00 117.00 01
D (LT AND BOILER) 1 275.85 275.85 275.85 275.85 02
Grand Total : 4 7813.27 7813.26 7813.27 7813.27 10


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MAIN BUILDING) B (COMPRESSOR) C (CHEMICAL AND CHINDI) D (LT AND BOILER)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 7204.86 7204.86 107.78 107.78 117.00 117.00 275.85 275.85 7705.49 7705.49
First Floor 0.00 0.00 107.78 107.78 0.00 0.00 0.00 0.00 107.78 107.78
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 7204.86 7204.86 215.56 215.56 117.00 117.00 275.85 275.85 7813.27 7813.27


[-] UnitBUA Table for Building :A (MAIN BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN B OTHER 916.86 867.42 68 5
C OTHER 133.57 132.59 9
D OTHER 54.14 53.24 6
MAIN BUILDING OTHER 5713.47 5639.62 2
TEMPLE OTHER 38.58 36.35 1
Total: - - 6856.62 6729.22 86 5
[-] UnitBUA Table for Building :B (COMPRESSOR) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN 2 OTHER 107.78 98.12 2 1
GROUND FLOOR PLAN 3 OTHER 107.78 98.88 1 1
Total: - - 215.56 197.00 3 2
[-] UnitBUA Table for Building :C (CHEMICAL AND CHINDI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN CHINDI AND CHEMICAL OTHER 117.00 111.87 2 1
Total: - - 117.00 111.87 2 1
[-] UnitBUA Table for Building :D (LT AND BOILER)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN BOILER AND BRIQUETTE OTHER 144.00 133.80 1 2
LT ROOM OTHER 99.00 95.50 1
Total: - - 243.00 229.30 2 2


[-] Building :A (MAIN BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 7204.86 7204.86 7204.86 7204.86 05
Total : 7204.86 7204.86 7204.86 7204.86 05
Total Number of Same Buildings : 1
Total : 7204.86 7204.86 7204.86 7204.86 05

[-] Building :B (COMPRESSOR)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 107.78 107.78 107.78 107.78 01
First Floor 107.78 107.78 107.78 107.78 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 215.56 215.55 215.56 215.56 02
Total Number of Same Buildings : 1
Total : 215.56 215.55 215.56 215.56 02

[-] Building :C (CHEMICAL AND CHINDI)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 117.00 117.00 117.00 117.00 01
Total : 117.00 117.00 117.00 117.00 01
Total Number of Same Buildings : 1
Total : 117.00 117.00 117.00 117.00 01

[-] Building :D (LT AND BOILER)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 275.85 275.85 275.85 275.85 02
Total : 275.85 275.85 275.85 275.85 02
Total Number of Same Buildings : 1
Total : 275.85 275.85 275.85 275.85 02
[-] Table 4c-2

  FAR Area
Building FAR Area:7813.26
Existing FAR Area :0.00
Perm.
48526.74
Prop.
7813.26
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MAIN BUILDING) 16 M WIDE SIKIDARI MAINROAD 12.00 12.31 9.00 99.45 9.00 14.41 9.00 12.82 OK
B-1 (COMPRESSOR) 16 M WIDE SIKIDARI MAINROAD 12.00 137.93 9.00 78.45 9.00 78.52 9.00 12.62 OK
C-1 (CHEMICAL AND CHINDI) 16 M WIDE SIKIDARI MAINROAD 12.00 207.63 9.00 13.64 9.00 13.74 9.00 77.74 OK
D-1 (LT AND BOILER) 16 M WIDE SIKIDARI MAINROAD 12.00 201.70 9.00 13.64 9.00 49.44 9.00 19.83 OK



[-] Building To Building Margin Check (Table 5b)
From Wing To Wing Margin Status
Reqd Prop
A-1 (MAIN BUILDING) B-1 (COMPRESSOR) 13.50 13.50 OK
C-1 (CHEMICAL AND CHINDI) 13.50 91.62 OK
D-1 (LT AND BOILER) 13.50 76.81 OK
B-1 (COMPRESSOR) A-1 (MAIN BUILDING) 13.50 13.50 OK
C-1 (CHEMICAL AND CHINDI) 13.50 75.85 OK
D-1 (LT AND BOILER) 13.50 55.81 OK
C-1 (CHEMICAL AND CHINDI) A-1 (MAIN BUILDING) 13.50 91.62 OK
B-1 (COMPRESSOR) 13.50 75.85 OK
D-1 (LT AND BOILER) 13.50 22.70 OK
D-1 (LT AND BOILER) A-1 (MAIN BUILDING) 13.50 76.81 OK
B-1 (COMPRESSOR) 13.50 55.81 OK
C-1 (CHEMICAL AND CHINDI) 13.50 22.70 OK






[-] Inner Building Details (Table 6)
   
   
[-] Passage Details

[-] For Building :A (MAIN BUILDING)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 1.20 mt. Wide Passage 6.61 1.00 1.20 - 5.58 OK
1.20 mt. Wide Passage 60.40 1.00 1.20 - 28.60 OK
1.20 mt. Wide Passage 38.06 1.00 1.20 - 16.93 OK
2.50 mt. Wide Passage 202.54 1.00 2.50 - 77.74 OK




No Passage Found.




No Passage Found.




No Passage Found.

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (MAIN BUILDING) Industrial Industrial Building > 0 400 7204.86 1 13 - - - -
> 0 400 7204.86 - - - 1 38 -
B (COMPRESSOR) Industrial Industrial Building > 0 400 215.55 1 1 - - - -
> 0 400 215.55 - - - 1 2 -
C (CHEMICAL AND CHINDI) Industrial Industrial Building > 0 400 117.00 1 1 - - - -
> 0 400 117.00 - - - 1 1 -
D (LT AND BOILER) Industrial Industrial Building > 0 400 275.85 1 1 - - - -
> 0 400 275.85 - - - 1 2 -
Total : - - - - 16 180 - 43 456

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 180 2250.00 OK
Total Car 16 200.00 180 2250.00 OK
TwoWheeler - - 456 912.00 OK
Total TwoWheeler 43 86.00 456 912.00 OK
Total 286.00 4074.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 4.50 - 4.70 OK
DRIVEWAY 4.50 - 4.70 OK
DRIVEWAY 4.50 - 4.70 OK
DRIVEWAY 4.50 - 4.70 OK
DRIVEWAY 4.50 - 4.60 OK
DRIVEWAY 4.50 - 4.60 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 3.00 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


No Staircase Found


[-] For Building :B (COMPRESSOR)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.300 - 0.000 - 0 2.100 - 2.700 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.500 0.225 0.300 0.200 0.150 - 12 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.750 1.500 0.225 0.300 0.200 0.152 - 14 - - 0.000 OK

No Staircase Found


No Staircase Found


   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 36.00 - - 6.00 - - 6.00 - - 0.00 OK
SUMP TANK - - 36.00 - - 6.00 - - 6.00 - - 0.00 OK
Sewage Treatment Plant - - 144.00 - - 9.00 - - 16.00 - - 0.00 OK
RAIN WATER HARVESTING - - 36.00 - - 6.00 - - 6.00 - - 0.00 OK
UG DIESEL TANK - - 100.00 - - 10.00 - - 10.00 - - 0.00 OK
DG - - 17.16 - - 2.60 - - 6.60 - - 0.00 OK
DG - - 17.16 - - 2.60 - - 6.60 - - 0.00 OK
ELECTRIC SUBSTATION - - 112.50 - - 9.00 - - 12.50 - - 0.00 OK
EFFLUENT TREATMENT PLANT - - 142.26 - - 8.89 - - 16.00 - - 0.00 OK
Fire Hydrants - - 36.00 - - 6.00 - - 6.00 - - 0.00 OK
ENT.GATE - - 1.57 - - 0.20 - - 8.01 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (MAIN BUILDING) Rain Water Harvesting 1 - 2 OK
Entrance Gate 1 - 1 OK
B (COMPRESSOR) Rain Water Harvesting 1 - 2 OK
C (CHEMICAL AND CHINDI) Rain Water Harvesting 1 - 2 OK
D (LT AND BOILER) Rain Water Harvesting 1 - 2 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MAIN BUILDING)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Building:B (COMPRESSOR)


[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:C (CHEMICAL AND CHINDI)


[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Building:D (LT AND BOILER)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 24263.37 OK
  Plot Width - 106.36 OK
  Plot Depth - 228.12 OK
  Access Width 9.00 16.00 OK
  Plot Frontage - 108.47 OK
  Coverage Area 12131.68 7705.48 OK
  FAR Area
Bldg. FAR Area : 7813.26
Sanctioned FAR Area :0.00
48526.74 7813.26 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Consumed FAR (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Industrial Building having plotarea 5000-30000 sq.mt., Margin required in Front shall be 12.0 mt., Rear 9.0 mt. and 9.0 mt. shall be provided on both side. {As per Rule No. 36 Table 12}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Building Height For new area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) No rule found for Mini. reqd Floor height
(2) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number No Rule Defined
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building UG DIESEL TANK
(9) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(10) No need to check distance from Building DG
(11) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(12) No need to check distance from Building ELECTRIC SUBSTATION
(13) -
(14) No need to check distance from Building EFFLUENT TREATMENT PLANT
(15) -
(16) No need to check distance from Building Fire Hydrants
(17) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)