No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 29-09-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0003/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGangati
Taluka0
Architect Details
Architect NameUJJAWAL KUMAR
License No.JIADA/ENG/0017/2019
Architect AddressINDU BHUSHAN SARKAR ROAD WILLAMS TOWN
Architect EmailIDujjawalkumar52@yahoo.com
Architect Mobile No9835573284
Plot Details
Plot Use Commercial
Plot SubUse Restaurant
PlotNearbyReligiousStructure NA
Plot/SubPlot NoEM- 6,7,8,9 & NS- 18
NorthRoad Width - 18.20
SouthPlot No. - TEMPLE
EastPlot No. - EM-05
WestRoad Width - 9.14
Owner's Details
NameSRI GAURAV KUMAR SINGH AND MRS NEHA
AddressINDUSTRIAL AREA JASIDIH PHASE-1 DEOGHAR
Email IDdr.gauravsingh86@gmail.com
Mobile No7061551424
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 10130.11
2 Plot area as per Document by Applicant 10130.11
3 Physical area measured at site 10011.94
4 Area as per Site Visit (Site Visit Report) 7684.54
5Area as per Drawing 7684.54

Area of Plot Considered : 7684.54

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Restaurant
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 7684.54
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 7684.54
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 6907.95
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 776.59
776.59
Balance Plot Area 6907.95

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 3842.27
Proposed Coverage Area ( 5.31 % ) 407.72
Total Prop. Coverage Area ( 5.31 % ) 407.72
Balance coverage area ( 44.69 % ) 3434.55
FAR CHECK
Perm. FAR Area ( 2.500 ) 19211.35
Total Perm. FAR area 19211.35
Commercial FAR 620.64
Proposed FAR Area 620.64
Total Proposed FAR Area 620.64
Consumed FAR (Factor) 0.08
Balance FAR Area 18590.71
BUA CHECK
Total Proposed BuiltUp Area 620.64


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 7684.54 7684.54
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 384.23 776.59 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 212.88 0.00 0.00 - 10.22 - 75.63 No Access Provided OK
Tree Cover (Plantation) - 563.71 0.00 0.00 - 13.37 - 75.23 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 10 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) Commercial Restaurant Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) 30.00 6.60 6.60 6.70 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) First Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 2.85 OK
Ground Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 2.85 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) - 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
3842.27 407.72 OK
50% 5.31%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRI GAURAV KUMAR SINGH AND MRS NEHA ) - 407.72
  Total Prop. Coverage Area - 407.72
  Total Coverage Area 3842.27 407.72

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Commercial
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) 1 620.64 620.64 620.64 620.64 02
Grand Total : 1 620.64 620.64 620.64 620.64 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI GAURAV KUMAR SINGH AND MRS NEHA )
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 407.72 407.72 407.72 407.72
First Floor 212.92 212.92 212.92 212.92
Terrace Floor 0.00 0.00 0.00 0.00
Total : 620.64 620.64 620.64 620.64


[-] UnitBUA Table for Building :A (SRI GAURAV KUMAR SINGH AND MRS NEHA )
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN RESTURANT OTHER 366.41 366.30 14 1
FIRST FLOOR PLAN MARRIAGE HALL OTHER 180.53 180.30 4 1
Total: - - 546.94 546.60 18 2


[-] Building :A (SRI GAURAV KUMAR SINGH AND MRS NEHA )
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Commercial
Ground Floor 407.72 407.72 407.72 407.72 01
First Floor 212.92 212.92 212.92 212.92 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 620.64 620.64 620.64 620.64 02
Total Number of Same Buildings : 1
Total : 620.64 620.64 620.64 620.64 02
[-] Table 4c-2

  FAR Area
Building FAR Area:620.64
Existing FAR Area :0.00
Perm.
19211.35
Prop.
620.64
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI GAURAV KUMAR SINGH AND MRS NEHA ) 18.20 mt. Wide MainRoad 9.00 10.15 6.00 41.39 6.00 6.16 6.00 50.29 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) Commercial Restaurant > 0 20 - 1 1 - - - -
> 0 20 - - - - 1 - -
Total : - - - - 1 8 - 0 13

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 8 100.00 OK
Total Car 1 12.50 8 100.00 OK
TwoWheeler - - 13 26.00 OK
Total TwoWheeler - - 13 26.00 OK
Total 12.50 152.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - 4.50M WIDE DRIVEWAY-1 4.50 - 4.80 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI GAURAV KUMAR SINGH AND MRS NEHA )
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.750 1.125 0.225 0.250 0.200 0.100 - 9 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.750 1.125 0.225 0.250 0.200 0.100 - 9 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 1.125 - 0.250 - 0.000 - 0 2.100 - 2.525 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 1.44 - - 1.20 - - 1.20 - - 0.00 OK
Toilet - 5.00 1.44 - - 1.20 - - 1.20 - - 0.00 OK
Swimming Pool - - 70.32 - - 7.03 - - 10.03 - - 0.00 OK
SEPTIC TANK - - 6.53 - - 1.82 - - 3.60 - - 0.00 OK
RAIN WATER HARVESTING - - 6.53 - - 1.82 - - 3.60 - - 0.00 OK
ENT.GATE - - 1.31 - - 0.25 - - 5.25 - - 0.00 OK
ENT.GATE - - 0.63 - - 0.13 - - 5.00 - - 0.00 OK
GUARD ROOM - 10.00 5.76 - - 2.40 - - 2.40 - - 0.00 OK
GUARD ROOM - 10.00 5.19 - - 2.10 - - 2.47 - - 0.00 OK
SOLAR HEATING SYSTEM - - 6.53 - - 1.82 - - 3.60 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI GAURAV KUMAR SINGH AND MRS NEHA ) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 2 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRI GAURAV KUMAR SINGH AND MRS NEHA )


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 500.00 7684.54 OK
  Plot Width - 103.03 OK
  Plot Depth - 74.58 OK
  Access Width 12.20 18.20 OK
  Plot Frontage - 93.03 OK
  Coverage Area 3842.27 407.72 OK
  FAR Area
Bldg. FAR Area : 620.64
Sanctioned FAR Area :0.00
19211.35 620.64 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Restaurant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Restaurant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Restaurant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Restaurant category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Restaurant category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Swimming Pool
(5) -
(6) No need to check distance from Building SEPTIC TANK
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building RAIN WATER HARVESTING
(9) No need to check distance from Building ENT.GATE
(10) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(11) No need to check distance from Building GUARD ROOM
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)