No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 27-06-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0016/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHATHIYADIH
Taluka0
Architect Details
Architect NameALOK KUMAR GADIA
License No.JIADA/ENG/0016/2021
Architect Address AC-9E, 11TH PHASE, ADARSH NAGAR SONARI, JAMSHDPUR-831011
Architect EmailIDagfibre2014@gmail.com
Architect Mobile No9431302078
Plot Details
Plot Use Industrial
Plot SubUse Industrial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot NoFE-11, (SERVEY PLOT NO- 348 (P) )
NorthPlot No. - FE-10, ( SURVEY PLOT NO. 348(P)
SouthPlot No. - FE-12, ( SURVEY PLOT NO. 348(P)
EastRoad Width - 20.50 MTR WIDE MAIN ROAD
WestPlot No. - FE-3 AND FE-2, ( SURVEY PLOT NO. 348(P)
Owner's Details
NameKRISHNA KUMAR SHARMA, PROPRIETORSHIP M/S. VANSHIKHA ENTERPRISES
AddressPlot No. FE-11, Phase-VII, Aditaypur Industrial Area, Gamharia
Email IDvikash.aiada@gmail.com
Mobile No6201315955
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 2719.50
2 Plot area as per Document by Applicant 2719.50
3 Physical area measured at site 2719.50
4 Area as per Site Visit (Site Visit Report) 2331.45
5Area as per Drawing 2330.49

Area of Plot Considered : 2330.49

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyIndustrial
Plot SubUse Industrial Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 2330.49
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 2330.49
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2037.26
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 293.23
293.23
Balance Plot Area 2037.26

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1165.24
Proposed Coverage Area ( 49.82 % ) 1161.13
Total Prop. Coverage Area ( 49.82 % ) 1161.13
Balance coverage area ( 0.18 % ) 4.11
FAR CHECK
Perm. FAR Area ( 2.00 ) 4660.98
Total Perm. FAR area 4660.98
Industrial FAR 1161.13
Proposed FAR Area 1161.13
Total Proposed FAR Area 1161.13
Consumed FAR (Factor) 0.50
Balance FAR Area 3499.85
BUA CHECK
Total Proposed BuiltUp Area 1161.13


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 20.5 20.50
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 2331.45 2330.49
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 233.05 293.23 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 293.23 0.00 0.00 - 6.89 - 89.81 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 9 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) Industrial Industrial Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) 41.17 9.60 9.60 9.60 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) Ground Floor 2.75 - 9.60 2.75 - 9.35 2.40 - 8.85 OK
Plinth 0.45 - 0.50 - - 0.50 - - 0.50 OK




No Floor Found.
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) - 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
1165.24 1161.13 OK
50% 49.82%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) - 1161.13
  Total Prop. Coverage Area - 1161.13
  Total Coverage Area 1165.24 1161.13

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) 1 1161.13 1161.13 1161.13 1161.13 01
Grand Total : 1 1161.13 1161.13 1161.13 1161.13 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA )
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 1161.13 1161.13 1161.13 1161.13
Total : 1161.13 1161.13 1161.13 1161.13


[-] UnitBUA Table for Building :A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA )
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN FACTORY OTHER 1129.50 1128.17 1 1
Total: - - 1129.50 1128.17 1 1


[-] Building :A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA )
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Industrial
Ground Floor 1161.13 1161.13 1161.13 1161.13 01
Total : 1161.13 1161.13 1161.13 1161.13 01
Total Number of Same Buildings : 1
Total : 1161.13 1161.13 1161.13 1161.13 01
[-] Table 4c-2

  FAR Area
Building FAR Area:1161.13
Existing FAR Area :0.00
Perm.
4660.98
Prop.
1161.13
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) 20.5 MTR WIDE MAIN ROAD Access Road 10.00 10.42 6.00 6.10 6.00 6.10 6.00 6.10 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) Industrial Industrial Building > 0 400 1161.13 1 2 - - - - - - -
> 0 400 1161.13 - - - - - - 1 7 -
Total : - - - - 2 8 - 0 1 - 7 34

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 8 100.00 OK
Total Car 2 25.00 8 100.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking - - 1 12.50 OK
TwoWheeler - - 34 68.00 OK
Total TwoWheeler 7 14.00 34 68.00 OK
Total 39.00 248.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 4.50 - 5.38 OK
DRIVEWAY 3.00 - 4.10 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


No Staircase Found


   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 4.58 - - 2.41 - - 2.42 - - 0.00 OK
ELECTRIC SUBSTATION - - 8.05 - - 2.84 - - 2.84 - - 0.00 OK
METER ROOM - - 8.05 - - 2.84 - - 2.84 - - 0.00 OK
ENT.GATE - - 3.76 - - 0.88 - - 4.26 - - 0.00 OK
SECURITY ROOM - 4.00 4.00 - 2.00 2.00 - 2.00 2.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.85 - - 1.56 - - 1.83 - - 0.00 OK
Generator Room - - 6.50 - - 1.94 - - 3.36 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA ) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MS VANSHIKA ENTERPRISES REPRESENTATIVE BY KRISHNA KUMAR SHARMA )


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 2330.49 OK
  Plot Width - 40.75 OK
  Plot Depth - 57.19 OK
  Access Width 9.00 20.50 OK
  Plot Frontage - 40.75 OK
  Coverage Area 1165.24 1161.13 OK
  FAR Area
Bldg. FAR Area : 1161.13
Sanctioned FAR Area :0.00
4660.98 1161.13 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Consumed FAR (1) For Industrial buildings non-polluting and household, the Floor Area Ratio-FAR shall be 2.0 {As per Rule No. 39.5}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Industrial Building having plotarea 1000-5000 sq.mt., Margin required in Front shall be 10.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 36 Table 12}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) No rule found for Mini. reqd Floor height
(2) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(4) No need to check distance from Building ELECTRIC SUBSTATION
(5) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(6) No need to check distance from Building METER ROOM
(7) No need to check distance from Building ENT.GATE
(8) Security Cabin of maximum size of 4 sq.m. with minimum width or diameter of 2 mt. shall be taken Free from FAR
(9) No need to check distance from Building SECURITY ROOM
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)