No Image Found   

Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 13-12-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0045/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHATHIYADIH
Taluka0
Architect Details
Architect NameL K SUMAN
License No.JIADA/ENG/0014/2021
Architect AddressSHOP NO. -2, BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR-831001
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Institutional
Plot SubUse Institutional Building
PlotNearbyReligiousStructure NA
Plot/SubPlot NoIC-6, SURVEY PLOT NO.- 354-P
NorthPlot No. - 354-P
SouthRoad Width - 18
EastPlot No. - 354-P
WestRoad Width - 25
Owner's Details
NameNETAJI SUBHAS MEDICAL COLLEGE AND HOSPITAL ,A UNIT OF SITWANTO DEVI MAHILA KALYAN SANSTHAN.
AddressPLOT NO.- IC-6, NEAR 7TH PHASE, ADITYAPUR INDUSTRIAL AREA, SERAIKELA-KHARSAWAN, JHARKHAND.
Email IDmritunjai1961@gmail.com
Mobile No9386467618
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 19243.26
2 Plot area as per Document by Applicant 19243.20
3 Physical area measured at site 19243.20
4 Area as per Site Visit (Site Visit Report) 19243.20
5Area as per Drawing 19243.20

Area of Plot Considered : 19243.20

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyInstitutional
Plot SubUse Institutional Building
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 19243.20
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 19243.20
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 16851.69
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 2391.51
2391.51
Balance Plot Area 16851.69

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 9621.60
Proposed Coverage Area ( 41.87 % ) 8056.49
Total Prop. Coverage Area ( 41.87 % ) 8056.49
Balance coverage area ( 8.13 % ) 1565.11
FAR CHECK
Perm. FAR Area ( 2.250 ) 43297.20
Total Perm. FAR area 43297.20
Special FAR 42791.45
Proposed FAR Area 43207.87
Total Proposed FAR Area 43207.87
Consumed FAR (Factor) 2.25
Balance FAR Area 89.32
BUA CHECK
Total Proposed BuiltUp Area 52285.91


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 25 25.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 19243.2 19243.20
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 1924.32 2391.51 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 496.34 0.00 0.00 - 9.75 - 74.30 No Access Provided OK
Tree Cover (Plantation) - 568.07 0.00 0.00 - 7.97 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 573.71 0.00 0.00 - 8.39 - 90.00 No Access Provided OK
Tree Cover (Plantation) - 753.39 0.00 0.00 - 2.44 - 73.18 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 40 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (INSTITUTIONAL BUILDING) Institutional Institutional Building Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (INSTITUTIONAL BUILDING) 55.50 24.68 25.80 24.68 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (INSTITUTIONAL BUILDING) Fifth Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Fourth Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Third Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Second Floor 2.75 - 4.00 2.75 - 3.85 2.40 - 3.55 OK
First Floor 2.75 - 4.00 2.75 - 3.85 2.40 - 3.55 OK
Ground Floor 2.75 - 4.00 2.75 - 3.85 2.40 - 3.55 OK
Lower Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.55 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (INSTITUTIONAL BUILDING) Terrace Floor - - 1.10 - - 1.10 - - 1.10 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (INSTITUTIONAL BUILDING) - 7 - 6 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
9621.60 8056.49 OK
50% 41.87%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (INSTITUTIONAL BUILDING) - 8056.49
  Total Prop. Coverage Area - 8056.49
  Total Coverage Area 9621.60 8056.49

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Ramp Parking Institutional Stair
A (INSTITUTIONAL BUILDING) 1 52285.91 611.10 826.85 7640.07 42791.45 314.58 43207.89 43207.89 06
Grand Total : 1 52285.91 611.10 826.85 7640.07 42791.45 314.58 43207.89 43207.89 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (INSTITUTIONAL BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Lower Ground Floor 8082.11 416.43 8082.11 416.43
Ground Floor 7367.30 7131.91 7367.30 7131.91
First Floor 7367.30 7131.91 7367.30 7131.91
Second Floor 7367.30 7131.91 7367.30 7131.91
Third Floor 7367.30 7131.91 7367.30 7131.91
Fourth Floor 7367.30 7131.91 7367.30 7131.91
Fifth Floor 7367.30 7131.91 7367.30 7131.91
Terrace Floor 0.00 0.00 0.00 0.00
Total : 52285.91 43207.89 52285.91 43207.89


[-] UnitBUA Table for Building :A (INSTITUTIONAL BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 6953.62 43 1
FIRST FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 6955.48 46 1
SECOND FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 6947.91 59 1
THIRD FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 6971.56 62 1
FOURTH FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 7002.25 62 1
FIFTH FLOOR PLAN INSTITUTIONAL BUILDING OTHER 7131.91 6978.57 62 1
Total: - - 42791.46 41809.39 334 6


[-] Building :A (INSTITUTIONAL BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Ramp Parking Institutional Stair
Lower Ground Floor 8082.11 0.00 25.61 7640.07 0.00 314.58 416.43 416.43 00
Ground Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
First Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
Second Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
Third Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
Fourth Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
Fifth Floor 7367.30 101.85 133.54 0.00 7131.91 0.00 7131.91 7131.91 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 52285.91 611.10 826.85 7640.07 42791.45 314.58 43207.89 43207.89 06
Total Number of Same Buildings : 1
Total : 52285.91 611.10 826.85 7640.07 42791.45 314.58 43207.89 43207.89 06
[-] Table 4c-2

  FAR Area
Building FAR Area:43207.88
Existing FAR Area :0.00
Perm.
43297.20
Prop.
43207.88
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (INSTITUTIONAL BUILDING) 18 M. WIDE Main Road 9.00 26.05 6.00 13.19 6.00 18.00 6.00 25.38 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (INSTITUTIONAL BUILDING) 24.68 2 16 - 0 12 96 OK

[-] Lift Check Table

[-] For Building :A (INSTITUTIONAL BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
LOWER GROUND FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
GROUND FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
FIRST FLOOR PLAN Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
SECOND FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
THIRD FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
FOURTH FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
FIFTH FLOOR PLAN Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.22 1.90 2.91 OK
Lift 1.70 2.15 1.90 2.91 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.22 1.90 2.91 OK
Lift Machine Room 1.70 2.15 1.90 2.91 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (INSTITUTIONAL BUILDING) Institutional Institutional Building > 0 150 42791.45 1 191 - - - -
> 0 150 - - - - 1 - -
> 0 150 42791.45 - - - 1 595 -
Total : - - - - 191 254 - 595 602

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 254 3175.00 OK
Total Car 191 2387.50 254 3175.00 OK
TwoWheeler - - 602 1204.00 OK
Total TwoWheeler 595 1190.00 602 1204.00 OK
Other Parking - - - 4021.07 OK
Total 3577.50 9604.07 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - 6.10 M. WIDE DRIVE WAY 3.00 - 6.10 OK
A (INSTITUTIONAL BUILDING) LOWER GROUND FLOOR PLAN 5.52 M. WIDE DRIVE WAY 4.50 - 4.50 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (INSTITUTIONAL BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
LOWER GROUND FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.115 - 11 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 13 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 12 - - 0.000 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
FOURTH FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
FIFTH FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK
STAIRCASE - 1.840 - 0.307 - 0.000 - 0 - - 2.700 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
4.20 mt. long 0.60 mt. High 6.10 mt. Wide Ramp - 4.20 - 0.60 - - - OK
48.00 mt. long 4.00 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 4.00 1.00 : 12.00 - 01 : 12 OK
48.00 mt. long 4.00 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 4.00 1.00 : 12.00 - 01 : 12 OK
48.00 mt. long 4.00 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 4.00 1.00 : 12.00 - 01 : 12 OK
43.20 mt. long 3.60 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 3.60 1.00 : 12.00 - 01 : 12 OK
43.20 mt. long 3.60 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 3.60 1.00 : 12.00 - 01 : 12 OK
43.20 mt. long 3.60 mt. High 5.44 mt. Wide Ramp For Handicapped 1.80 5.44 1.00 3.60 1.00 : 12.00 - 01 : 12 OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (INSTITUTIONAL BUILDING) LOWER GROUND FLOOR PLAN - 1 OK
GROUND FLOOR PLAN - 1 OK
FIRST FLOOR PLAN - 1 OK
SECOND FLOOR PLAN - 1 OK
THIRD FLOOR PLAN - 1 OK
FOURTH FLOOR PLAN - 1 OK
FIFTH FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 5.00 - - 1.95 - - 2.57 - - 0.00 OK
RAIN WATER HARVESTING - - 127.21 - - 10.60 - - 12.01 - - 0.00 OK
ENT.GATE - - 8.07 - - 0.70 - - 12.20 - - 0.00 OK
ENT.GATE - - 2.73 - - 0.45 - - 6.39 - - 0.00 OK
ENT.GATE - - 8.07 - - 0.70 - - 12.20 - - 0.00 OK
SOLAR HEATING SYSTEM - - 55.72 - - 5.22 - - 10.68 - - 0.00 OK
SOLAR HEATING SYSTEM - - 57.66 - - 4.87 - - 11.84 - - 0.00 OK
SOLAR HEATING SYSTEM - - 76.39 - - 4.99 - - 15.32 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (INSTITUTIONAL BUILDING) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 1 OK
Entrance Gate 1 - 3 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (INSTITUTIONAL BUILDING)


[-] Floor:LOWER GROUND FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FOURTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIFTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 10000.00 19243.20 OK
  Plot Width - 208.25 OK
  Plot Depth - 92.40 OK
  Access Width 12.20 25.00 OK
  Plot Frontage - 76.30 OK
  Coverage Area 9621.60 8056.49 OK
  FAR Area
Bldg. FAR Area : 43207.88
Sanctioned FAR Area :0.00
43297.20 43207.88 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Technical educational institution category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) 0.0
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Institutional Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.2}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height No rule found for Mini. reqd Floor height
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp (1) No rule Define.
(2) ; Minimum width of ramp for Handicapped shall be 1800 mm. with maximum gradient 1:12. length of ramp shall not exceed 9 meter {As per Rule No. 50.7.2} ;
Ramp No. -
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)