Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 19-10-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0039/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageTati
Taluka0
Architect Details
Architect NameNikhil Jain
License No.JIADA/ARC/0001/2018
Architect AddressBothra Bhawan, Opposite Indra Place, Main Road, Hinoo
Architect EmailIDbdpranchi@gmail.com
Architect Mobile No8087667001
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot NoIndustrial Plot No. 13P; Survey Plot No. 1201P, 1202P, 1203P
NorthRoad Width - 21.3
SouthSurvey No. - Survey Plot No. 1200P, 1203P & Industrial Plot No. 14
EastSurvey No. - Survey Plot No. 1202P, 1203P & 1204P
WestSurvey No. - Survey Plot No. 1201P & Industrial Plot No. 13P
Owner's Details
NameSRS PARK represented by Harcharan Singh Namdhari
AddressIndustrial Plot No. 13P, Tatisilwai Industrial Area Phase - 1, Khelgaon Road, Tatisilwai, Ranchi, Jharkhand
Email IDharnamsaluja@gmail.com
Mobile No9264450258
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1082.32
2 Plot area as per Document by Applicant 1082.32
3 Physical area measured at site 998.34
4 Area as per Site Visit (Site Visit Report) 1082.32
5Area as per Drawing 998.34

Area of Plot Considered : 998.34

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 998.34
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 998.34
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 887.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 110.80
110.80
Balance Plot Area 887.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 499.17
Proposed Coverage Area ( 43.89 % ) 438.18
Total Prop. Coverage Area ( 43.89 % ) 438.18
Balance coverage area ( 6.11 % ) 60.99
FAR CHECK
Perm. FAR Area ( 3.000 ) 2995.02
Total Perm. FAR area 2995.02
Commercial FAR 2471.50
Proposed FAR Area 2491.29
Total Proposed FAR Area 2491.29
Consumed FAR (Factor) 2.50
Balance FAR Area 503.73
BUA CHECK
Total Proposed BuiltUp Area 3139.47


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 21.3 21.30
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 1082.32 998.34
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 99.83 110.80 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 10.66 No Access Provided OK
Normal Open Space - 12.30 No Access Provided OK
Normal Open Space - 27.00 No Access Provided OK
Normal Open Space - 60.83 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 10 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRS PARK) Commercial Commercial Bldg Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (SRS PARK) 23.10 23.10 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRS PARK) Sixth Floor 2.75 - 2.98 2.75 - 2.93 2.40 - 2.71 OK
Fifth Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
Fourth Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
Third Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
Second Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
First Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
Ground Floor 2.75 - 3.35 2.75 - 3.31 2.40 - 3.09 OK
Plinth 0.45 - 0.75 - - 0.75 - - 0.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRS PARK) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRS PARK) - 7 - 6 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
499.17 438.18 OK
50% 43.89%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRS PARK) - 438.18
  Total Prop. Coverage Area - 438.18
  Total Coverage Area 499.17 438.18

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Balcony Accessory Use Parking Commercial Stair
A (SRS PARK) 1 3139.47 95.06 52.92 95.40 9.75 395.05 2471.50 10.97 2491.29 2491.29 06
Grand Total : 1 3139.47 95.06 52.92 95.40 9.75 395.05 2471.50 10.97 2491.29 2491.29 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRS PARK)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 438.17 19.79 438.17 19.79
First Floor 498.35 456.87 498.35 456.87
Second Floor 498.35 456.87 498.35 456.87
Third Floor 498.35 456.87 498.35 456.87
Fourth Floor 498.35 456.87 498.35 456.87
Fifth Floor 498.35 456.87 498.35 456.87
Sixth Floor 209.55 187.15 209.55 187.15
Terrace Floor 0.00 0.00 0.00 0.00
Total : 3139.47 2491.29 3139.47 2491.29


[-] UnitBUA Table for Building :A (SRS PARK)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN HALL OTHER 379.05 375.52 3 5
SIXTH FLOOR PLAN HALL OTHER 140.54 133.71 1 1
Total: - - 2035.80 2011.31 16 6


[-] Building :A (SRS PARK)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Balcony Accessory Use Parking Commercial Stair
Ground Floor 438.17 13.58 0.00 0.00 9.75 395.05 0.00 10.97 19.79 19.79 00
First Floor 498.35 13.58 8.82 19.08 0.00 0.00 456.87 0.00 456.87 456.87 01
Second Floor 498.35 13.58 8.82 19.08 0.00 0.00 456.87 0.00 456.87 456.87 01
Third Floor 498.35 13.58 8.82 19.08 0.00 0.00 456.87 0.00 456.87 456.87 01
Fourth Floor 498.35 13.58 8.82 19.08 0.00 0.00 456.87 0.00 456.87 456.87 01
Fifth Floor 498.35 13.58 8.82 19.08 0.00 0.00 456.87 0.00 456.87 456.87 01
Sixth Floor 209.55 13.58 8.82 0.00 0.00 0.00 187.15 0.00 187.15 187.15 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 3139.47 95.06 52.92 95.40 9.75 395.05 2471.50 10.97 2491.29 2491.29 06
Total Number of Same Buildings : 1
Total : 3139.47 95.06 52.92 95.40 9.75 395.05 2471.50 10.97 2491.29 2491.29 06
[-] Table 4c-2

  FAR Area
Building FAR Area:2491.29
Existing FAR Area :0.00
Perm.
2995.02
Prop.
2491.29
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRS PARK) 21.3 M ROAD 7.50 7.50 4.50 4.50 4.50 4.50 4.50 4.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SRS PARK)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN BALCONY-2 1.20 1.20 OK
BALCONY-1 1.20 1.20 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SRS PARK) 23.10 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :A (SRS PARK)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.95 1.90 1.95 OK
TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.95 1.90 1.95 OK
SIXTH FLOOR PLAN Lift 1.70 1.83 1.90 2.74 OK
Lift 1.70 1.95 1.90 1.95 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.83 1.90 2.74 OK
Lift Machine Room 1.70 1.95 1.90 1.95 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SRS PARK) Commercial Commercial Bldg > 0 200 2405.67 1 9 - - - -
> 0 200 2405.67 - - - 1 26 -
Total : - - - - 9 13 - 26 28

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 13 162.50 OK
Total Car 9 112.50 13 162.50 OK
TwoWheeler - - 28 56.00 OK
Total TwoWheeler 26 52.00 28 56.00 OK
Other Parking - - - 176.55 OK
Total 164.50 451.05 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (SRS PARK) GROUND FLOOR PLAN DRIVEWAY-1 3.60 - 7.63 OK
DRIVEWAY-2 3.60 - 6.87 OK
DRIVEWAY-3 3.60 - 7.00 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRS PARK)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Fire Escape Staircase 0.900 1.524 0.250 0.254 0.200 0.140 16 12 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.140 - 12 - - 0.000 OK
TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN Fire Escape Staircase 0.900 1.524 0.250 0.254 0.200 0.140 16 12 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.140 - 12 - - 0.000 OK
SIXTH FLOOR PLAN Fire Escape Staircase 0.900 1.524 0.250 0.254 0.200 0.124 16 12 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.124 - 12 - - 0.000 OK
TERRACE FLOOR PLAN HEAD ROOM - 1.524 - 0.254 - 0.000 - 0 - - 2.100 OK
HEAD ROOM - 1.219 - 0.254 - 0.000 - 0 - - 2.100 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (SRS PARK)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN C.B. 0.60 0.60 - 20.86 - 12.41 OK
C.B. 0.60 0.60 - 7.13 - 4.24 OK
C.B. 0.60 0.60 - 9.01 - 5.36 OK
SIXTH FLOOR PLAN C.B. 0.60 0.60 - 20.86 - 12.41 OK
C.B. 0.60 0.60 - 7.13 - 4.24 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 3.25 - - 1.52 - - 2.13 - - 0.00 OK
Toilet - 5.00 3.25 - - 1.52 - - 2.13 - - 0.00 OK
Toilet - 5.00 3.25 - - 1.52 - - 2.13 - - 0.00 OK
GENSET - - 2.18 - - 1.19 - - 1.83 - - 0.00 OK
SEPTIC TANK - - 4.62 - - 1.53 - - 3.03 - - 0.00 OK
METER ROOM - - 7.15 - - 2.13 - - 3.36 - - 0.00 OK
UG TANK - - 2.97 - - 1.22 - - 2.44 - - 0.00 OK
RAIN WATER HARVESTING - - 2.16 - - 1.22 - - 1.77 - - 0.00 OK
ENT.GATE - - 1.04 - - 0.37 - - 2.89 - - 0.00 OK
GUARD ROOM - 10.00 7.20 - - 2.40 - - 3.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.02 - - 1.89 - - 2.13 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRS PARK) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 3 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRS PARK)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1, 2, 3, 4, 5 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SIXTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 998.34 OK
  Plot Width - 30.94 OK
  Plot Depth - 32.27 OK
  Access Width 6.10 21.30 OK
  Plot Frontage - 29.31 OK
  Coverage Area 499.17 438.18 OK
  FAR Area
Bldg. FAR Area : 2491.29
Sanctioned FAR Area :0.00
2995.02 2491.29 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In New Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 19.25-23.10 mt.,Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number No Rule Defined
Balcony Projected balcony may be allowed with a width of 1.2 mt. where the setback is more than 4.5 mt. and 4.5 mt. respectively clear driveway is available for the Fire tender movement {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
(5) No Rule Defined
(6) ; No Rule Defined
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building GENSET
(5) -
(6) No need to check distance from Building SEPTIC TANK
(7) -
(8) No need to check distance from Building METER ROOM
(9) -
(10) No need to check distance from Building UG TANK
(11) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(12) No need to check distance from Building RAIN WATER HARVESTING
(13) No need to check distance from Building ENT.GATE
(14) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(15) No need to check distance from Building GUARD ROOM
(16) -
(17) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)