Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 26-07-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0011/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHATHIYADIH
Taluka0
Architect Details
Architect NameL K SUMAN
License No.JIADA/ENG/0014/2021
Architect AddressSHOP NO. -2, BASANT TALKIES COMPLEX SAKCHI JAMSHEDPUR-831001
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Institutional
Plot SubUse Institutional Building
PlotNearbyReligiousStructure NA
Plot/SubPlot NoIT 8 (P)-A, IT- 9, IT- 10
NorthPlot No. - OTHER'S PLOT
SouthRoad Width - 18 MTR.
EastPlot No. - OTHER'S PLOT
WestPlot No. - OTHER'S PLOT
Owner's Details
NameNETAJI SUBHAS MEDICAL COLLEGE AND HOSPITAL, A UNIT OF SITWANTO DEVI MAHILA KALYAN SANSTHAN
AddressPLOT NO.- IT 8 (P)-A, IT-9, IT-10, MOUZA - HATIYADIH AND BHATIA, NEAR PHASE - 7, ADITYAPUR INDUSTRIAL AREA.
Email IDmritunjai1961@gmail.com
Mobile No9386467618
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 11071.89
2 Plot area as per Document by Applicant 11071.89
3 Physical area measured at site 11071.89
4 Area as per Site Visit (Site Visit Report) 11071.89
5Area as per Drawing 11071.89

Area of Plot Considered : 11071.89

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyInstitutional
Plot SubUse Institutional Building
Building StructureMultistoried
Building TypeNA
Gross Plot Area 11071.89
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 11071.89
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 9813.56
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 1258.33
1258.33
Balance Plot Area 9813.56

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 5535.94
Proposed Coverage Area ( 49.33 % ) 5461.75
Total Prop. Coverage Area ( 49.33 % ) 5461.75
Balance coverage area ( 0.67 % ) 74.19
FAR CHECK
Perm. FAR Area ( 2.250 ) 24911.75
Total Perm. FAR area 24911.75
Special FAR 24590.70
Proposed FAR Area 24694.73
Total Proposed FAR Area 24694.73
Consumed FAR (Factor) 2.23
Balance FAR Area 217.02
BUA CHECK
Total Proposed BuiltUp Area 28026.58


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 18 18.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 11071.89 11071.89
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 1107.19 1258.33 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 1258.33 0.00 0.00 - 12.96 - 88.90 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MEDICAL INSTITUTIONAL BUILDING) Institutional Institutional Building Multistoried
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) 30.00 21.60 21.60 21.60 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) Fifth Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Fourth Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Third Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Second Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
First Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Ground Floor 2.75 - 3.60 2.75 - 3.45 2.40 - 3.15 OK
Basement Floor 2.40 - 3.00 2.40 - 2.85 2.10 - 2.55 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) Terrace Floor - - 1.10 - - 1.10 - - 1.10 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (MEDICAL INSTITUTIONAL BUILDING) Basement Floor 0.90 1.50 0.90 - 2370.06 - 2.82 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) - 2370.06
Total - 2370.06 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (MEDICAL INSTITUTIONAL BUILDING)   18 M. WIDE Main Road 9.00 25.08 6.00 12.98 6.00 69.34 6.00 8.96 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) - 6 - 12 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
5535.94 5461.75 OK
50% 49.33%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MEDICAL INSTITUTIONAL BUILDING) - 5461.75
  Total Prop. Coverage Area - 5461.75
  Total Coverage Area 5535.94 5461.75

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout StairCase Lift Lift Machine Accessory Use Parking Institutional Stair
A (MEDICAL INSTITUTIONAL BUILDING) 1 32030.21 4003.63 28026.58 737.77 278.09 42.21 5.00 2268.78 24590.70 104.04 24694.73 24694.73 12
Grand Total : 1 32030.21 4003.63 28026.58 737.77 278.09 42.21 5.00 2268.78 24590.70 104.04 24694.73 24694.73 12


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MEDICAL INSTITUTIONAL BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 2370.06 36.50 2370.06 36.50
Ground Floor 5653.25 5461.75 5653.25 5461.75
First Floor 4671.40 4511.04 4671.40 4511.04
Second Floor 4666.23 4505.87 4666.23 4505.87
Third Floor 4666.23 4505.87 4666.23 4505.87
Fourth Floor 4666.23 4505.87 4666.23 4505.87
Fifth Floor 1333.18 1167.83 1333.18 1167.83
Terrace Floor 0.00 0.00 0.00 0.00
Total : 28026.58 24694.73 28026.58 24694.73


[-] UnitBUA Table for Building :A (MEDICAL INSTITUTIONAL BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN Medical Institution OTHER 4612.43 4443.97 128 1
SECOND FLOOR PLAN Medical Hostel OTHER 1131.33 1073.51 57 3
Medical Hostel OTHER 1131.33 1073.51 57
Medical Institution OTHER 2344.60 2297.36 13
GROUND FLOOR PLAN Medical Institution OTHER 5594.29 5483.68 44 1
TYPICAL - 3& 4 FLOOR PLAN Medical Hostel OTHER 1131.33 1073.51 57 6
Medical Hostel OTHER 1131.33 1073.51 57
Medical Institution OTHER 2344.60 2283.88 14
FIFTH FLOOR PLAN Medical Hostel OTHER 1131.33 1073.51 57 1
Total: - - 25159.83 24307.33 612 12


[-] Building :A (MEDICAL INSTITUTIONAL BUILDING)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout StairCase Lift Lift Machine Accessory Use Parking Institutional Stair
Basement Floor 2372.88 2.82 2370.06 39.32 25.46 0.00 0.00 2268.78 0.00 36.50 36.50 36.50 00
Ground Floor 5664.54 11.29 5653.25 191.50 0.00 0.00 0.00 0.00 5461.75 0.00 5461.75 5461.75 01
First Floor 5470.15 798.75 4671.40 101.39 58.97 0.00 0.00 0.00 4511.04 0.00 4511.04 4511.04 01
Second Floor 5464.98 798.75 4666.23 101.39 58.97 0.00 0.00 0.00 4505.87 0.00 4505.87 4505.87 03
Third Floor 5464.98 798.75 4666.23 101.39 58.97 0.00 0.00 0.00 4505.87 0.00 4505.87 4505.87 03
Fourth Floor 5464.98 798.75 4666.23 101.39 58.97 0.00 0.00 0.00 4505.87 0.00 4505.87 4505.87 03
Fifth Floor 2127.70 794.52 1333.18 101.39 16.75 42.21 5.00 0.00 1100.30 67.54 1167.83 1167.83 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 32030.21 4003.63 28026.58 737.77 278.09 42.21 5.00 2268.78 24590.70 104.04 24694.73 24694.73 12
Total Number of Same Buildings : 1
Total : 32030.21 4003.63 28026.58 737.77 278.09 42.21 5.00 2268.78 24590.70 104.04 24694.73 24694.73 12
[-] Table 4c-2

  FAR Area
Building FAR Area:24694.73
Existing FAR Area :0.00
Perm.
24911.75
Prop.
24694.73
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MEDICAL INSTITUTIONAL BUILDING) 18 M. WIDE Main Road 9.00 9.19 6.00 7.77 6.00 6.61 6.00 8.96 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (MEDICAL INSTITUTIONAL BUILDING) 21.60 3 4 - 0 18 24 OK

[-] Lift Check Table

[-] For Building :A (MEDICAL INSTITUTIONAL BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
FIRST FLOOR PLAN Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
SECOND FLOOR PLAN Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
BASEMENT FLOOR PLAN Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
GROUND FLOOR PLAN Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
TYPICAL - 3& 4 FLOOR PLAN Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 2.18 1.90 2.91 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.92 1.90 2.45 OK
Lift Machine Room 1.70 1.92 1.90 1.92 OK
Lift Machine Room 1.70 1.92 1.90 2.45 OK
Lift Machine Room 1.70 1.92 1.90 1.92 OK
FIFTH FLOOR PLAN Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift 1.70 1.92 1.90 2.45 OK
Lift 1.70 1.92 1.90 1.92 OK
Lift Machine Room 1.70 1.92 1.90 2.45 OK
Lift Machine Room 1.70 1.92 1.90 1.92 OK
Lift Machine Room 1.70 1.92 1.90 2.45 OK
Lift Machine Room 1.70 1.92 1.90 1.92 OK
Lift Machine Room 1.70 2.18 1.90 2.91 OK
Lift Machine Room 1.70 2.18 1.90 2.91 OK
Lift Machine Room 1.70 2.18 1.90 2.91 OK
Lift Machine Room 1.70 2.18 1.90 2.91 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (MEDICAL INSTITUTIONAL BUILDING) Institutional Institutional Building > 0 150 24590.70 1 110 - - - -
> 0 150 - - - - 1 - -
> 0 150 24590.70 - - - 1 342 -
Total : - - - - 110 137 - 342 348

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 137 1712.50 OK
Total Car 110 1375.00 137 1712.50 OK
TwoWheeler - - 348 696.00 OK
Total TwoWheeler 342 684.00 348 696.00 OK
Other Parking - - - 1076.78 OK
Total 2059.00 4181.28 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - 6.10 M. WIDE DRIVE WAY 4.50 - 6.00 OK
DRIVEWAY 3.00 - 3.00 OK
DRIVEWAY 3.00 - 4.50 OK
DRIVEWAY 3.00 - 4.50 OK
DRIVEWAY 3.00 - 4.52 OK
A (MEDICAL INSTITUTIONAL BUILDING) BASEMENT FLOOR PLAN DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 4.72 OK
DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 5.00 OK
DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 5.00 OK
DRIVEWAY 4.50 - 4.50 OK
DRIVEWAY 4.50 - 4.50 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (MEDICAL INSTITUTIONAL BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
SECOND FLOOR PLAN Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
BASEMENT FLOOR PLAN Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.000 16 0 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
TYPICAL - 3& 4 FLOOR PLAN Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
TERRACE FLOOR PLAN Fire Escape Staircase - 1.533 - 0.307 - 0.000 16 0 - - 2.700 OK
STAIRCASE - 1.533 - 0.307 - 0.000 - 0 - - 2.700 OK
FIFTH FLOOR PLAN Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.533 0.250 0.307 0.200 0.138 16 10 - - 0.000 OK
STAIRCASE 0.900 1.533 0.250 0.307 0.200 0.138 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.840 0.250 0.307 0.200 0.138 16 11 - - 0.000 OK
STAIRCASE 0.900 1.840 0.250 0.307 0.200 0.138 - 11 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
14.70 mt. long 2.10 mt. High 6.00 mt. Wide Ramp - 6.00 - 2.10 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (MEDICAL INSTITUTIONAL BUILDING) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 5.00 - - 1.95 - - 2.57 - - 0.00 OK
RAIN WATER HARVESTING - - 6.16 - - 0.97 - - 6.39 - - 0.00 OK
ENT.GATE - - 8.87 - - 0.73 - - 12.20 - - 0.00 OK
SOLAR HEATING SYSTEM - - 32.29 - - 4.45 - - 7.26 - - 0.00 OK
SOLAR HEATING SYSTEM - - 28.53 - - 4.31 - - 6.63 - - 0.00 OK
SOLAR HEATING SYSTEM - - 39.93 - - 4.16 - - 9.60 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (MEDICAL INSTITUTIONAL BUILDING) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MEDICAL INSTITUTIONAL BUILDING)


[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 3& 4 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIFTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 10000.00 11071.89 OK
  Plot Width - 126.38 OK
  Plot Depth - 87.61 OK
  Access Width 12.20 18.00 OK
  Plot Frontage - 126.25 OK
  Coverage Area 5535.94 5461.75 OK
  FAR Area
Bldg. FAR Area : 24694.73
Sanctioned FAR Area :0.00
24911.75 24694.73 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Technical educational institution category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Technical educational institution category shall be 10000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) 0.0
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) 0.0
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Institutional Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.2}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) No rule found for Mini. reqd Floor height
(2) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(7) No Rule Defined
(8) ; No Rule Defined
Ramp No rule Define. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is more then 500sq.mt.,atleast two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved or one ramp of minimum 5.4m width shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)