Detail Scrutiny Report

JHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 22-07-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityJHARKHAND INDUSTRIAL AREA DEVELOPMENT AUTHORITY
Inward_NoJIADA/BP/0019/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKokar
Taluka0
Architect Details
Architect NameChandravijay Pradhan
License No.JIADA/ARC/0009/2020
Architect EmailIDpradhan.chandra14@gmail.com
Architect Mobile No7276157012
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot NoIndustrial Plot No. - 265P-C, Survey Plot No. - 55P
NorthPlot No. - Industrial Plot No 265P - B
SouthPlot No. - Industrial Plot No 265P - D
EastRoad Width - 35
WestRoad Width - 13
Owner's Details
NameRavindra Pradhan
Address265P-C, Tupudana Industrial Area
Email IDravindrapradhan1606@gmail.com
Mobile No9431170302
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1858.00
2 Plot area as per Document by Applicant 1858.00
3 Area as per Site Visit (Site Visit Report) 1858.00
4Area as per Drawing 1857.94

Area of Plot Considered : 1857.94

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1857.94
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1857.94
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1752.95
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 105.00
105.00
Balance Plot Area 1752.95

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 928.97
Proposed Coverage Area ( 22.91 % ) 425.71
Total Prop. Coverage Area ( 22.91 % ) 425.71
Balance coverage area ( 27.09 % ) 503.26
FAR CHECK
Perm. FAR Area ( 3.000 ) 5573.82
Total Perm. FAR area 5573.82
Commercial FAR 1412.71
Proposed FAR Area 1437.64
Total Proposed FAR Area 1437.64
Consumed FAR (Factor) 0.77
Balance FAR Area 4136.18
BUA CHECK
Total Proposed BuiltUp Area 1865.93


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 30.34 30.34
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 1858 1857.94
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 92.90 105.00 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 105.00 0.00 0.00 - 3.82 - 89.96 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 8 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Commercial Commercial Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (BUILDING) 8.55 8.55 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.48 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.48 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.48 OK
Basement Floor 2.40 - 2.85 2.40 - 2.75 2.10 - 2.48 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (BUILDING) Basement Floor 0.90 1.50 1.20 - 425.71 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (BUILDING) - 425.71
Total - 425.71 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (BUILDING)   30.34 MT WIDE ROAD 2.00 9.00 2.00 6.00 2.00 25.50 2.00 6.00 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) - 3 - 6 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (BUILDING) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
928.97 425.71 OK
50% 22.91%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 425.71
  Total Prop. Coverage Area - 425.71
  Total Coverage Area 928.97 425.71

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Commercial Stair
A (BUILDING) 1 1865.93 21.78 12.99 393.53 1412.71 24.93 1437.64 1437.64 06
Grand Total : 1 1865.93 21.78 12.99 393.53 1412.71 24.93 1437.64 1437.64 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 425.71 24.93 425.71 24.93
Ground Floor 425.71 421.38 425.71 421.38
First Floor 507.26 495.67 507.26 495.67
Second Floor 507.25 495.66 507.25 495.66
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1865.93 1437.64 1865.93 1437.64


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN A SHOP 7.96 7.66 1 2
A1 SHOP 323.37 322.51 5
FIRST FLOOR PLAN A2 SHOP 116.11 114.89 1 2
A3 SHOP 312.90 312.54 4
SECOND FLOOR PLAN A4 SHOP 116.11 114.88 1 2
A5 SHOP 312.89 312.54 4
Total: - - 1189.34 1185.03 16 6


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Void Parking Commercial Stair
Basement Floor 425.71 7.26 0.00 393.53 0.00 24.93 24.93 24.93 00
Ground Floor 425.71 0.00 4.33 0.00 421.38 0.00 421.38 421.38 02
First Floor 507.26 7.26 4.33 0.00 495.67 0.00 495.67 495.67 02
Second Floor 507.25 7.26 4.33 0.00 495.66 0.00 495.66 495.66 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1865.93 21.78 12.99 393.53 1412.71 24.93 1437.64 1437.64 06
Total Number of Same Buildings : 1
Total : 1865.93 21.78 12.99 393.53 1412.71 24.93 1437.64 1437.64 06
[-] Table 4c-2

  FAR Area
Building FAR Area:1437.64
Existing FAR Area :0.00
Perm.
5573.82
Prop.
1437.64
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 30.34 MT WIDE ROAD 9.00 9.00 6.00 6.00 6.00 25.50 6.00 6.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Passage Details

[-] For Building :A (BUILDING)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 2.43 mt. Wide Passage 30.86 1.00 2.44 - 12.65 OK
2.75 mt. Wide Passage 20.01 1.00 2.75 - 7.03 OK
FIRST FLOOR PLAN 2.43 mt. Wide Passage 30.86 1.00 2.44 - 12.65 OK
SECOND FLOOR PLAN 2.43 mt. Wide Passage 30.86 1.00 2.44 - 12.65 OK

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING) 8.55 - 2 - 0 - 12 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.91 1.90 1.91 OK
Lift 1.70 1.91 1.90 1.91 OK
FIRST FLOOR PLAN Lift 1.70 1.91 1.90 1.91 OK
Lift 1.70 1.91 1.90 1.91 OK
SECOND FLOOR PLAN Lift 1.70 1.91 1.90 1.91 OK
Lift 1.70 1.91 1.90 1.91 OK
TERRACE FLOOR PLAN Lift 1.70 1.91 1.90 1.91 OK
Lift 1.70 1.91 1.90 1.91 OK
Lift Machine Room 1.70 2.16 1.90 4.07 OK
BASEMENT FLOOR PLAN Lift 1.70 1.91 1.90 1.91 OK
Lift 1.70 1.91 1.90 1.91 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Commercial Commercial Bldg > 0 200 1214.72 1 5 - - - -
> 0 200 1214.72 - - - 1 13 -
Total : - - - - 5 17 - 13 24

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 17 212.50 OK
Total Car 5 62.50 17 212.50 OK
TwoWheeler - - 24 48.00 OK
Total TwoWheeler 13 26.00 24 48.00 OK
Other Parking - - - 181.03 OK
Total 88.50 489.53 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (BUILDING) BASEMENT FLOOR PLAN DRIVEWAY 3.60 - 4.51 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.999 0.250 0.254 0.200 0.150 - 10 - - 0.000 OK
STAIRCASE 0.900 1.473 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 0.999 0.250 0.254 0.200 0.150 - 10 - - 0.000 OK
STAIRCASE 0.900 1.473 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.999 0.250 0.254 0.200 0.150 - 10 - - 0.000 OK
STAIRCASE 0.900 1.473 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.999 - 0.254 - 0.000 - 0 - - 2.400 OK
STAIRCASE - 1.473 - 0.254 - 0.000 - 0 - - 2.400 OK
BASEMENT FLOOR PLAN STAIRCASE 0.900 0.999 0.250 0.254 0.200 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.473 0.250 0.254 0.200 0.000 - 0 - - 0.000 OK

   
   
   

[-] Ramp Checks(Table 8b)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
10.00 mt. long 1.00 mt. High 5.37 mt. Wide Natural Slope - 5.37 - 1.00 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (BUILDING) GROUND FLOOR PLAN - 1 OK
FIRST FLOOR PLAN - 1 OK
SECOND FLOOR PLAN - 1 OK
TERRACE FLOOR PLAN - 1 OK
BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SEPTIC TANK - - 3.42 - - 1.22 - - 2.82 - - 0.00 OK
RAIN WATER HARVESTING - - 1.14 - - 0.71 - - 1.61 - - 0.00 OK
ENT.GATE - - 0.60 - - 0.15 - - 4.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.49 - - 0.82 - - 1.81 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:BASEMENT FLOOR PLAN



No Room Found.



   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1857.94 OK
  Plot Width - 60.96 OK
  Plot Depth - 30.48 OK
  Access Width - 30.34 OK
  Plot Frontage - 60.96 OK
  Coverage Area 928.97 425.71 OK
  FAR Area
Bldg. FAR Area : 1437.64
Sanctioned FAR Area :0.00
5573.82 1437.64 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Non-Residential Building on abutting roadwidth 24.40 mt. (80 ft.) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In New Area, for Non-Residential Building on abutting roadwidth 24.40 mt. (80 ft.) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number No Rule Defined
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) -
(2) For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)