RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0014/W23/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameAASHUTOSH KUMAR
License No.DGMC/ENG/0018/2017
Architect AddressBAWAN BIGHA, RED ROSE SCHOOL ROAD,BEHIND MAA LALITA HOSPITAL,DEOGHAR,PIN - 814112,JHARKHAND.
Architect EmailIDshivconstruction555@gmail.com
Architect Mobile No9771401090
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No44/A
NorthRoad Width - 15.10
SouthPlot No. - 44
EastRoad Width - 15
WestPlot No. - 44
Owner's Details
NameROHIT KUMAR MONA KASHYAP
AddressS/O DHRUW NARATAN THAKUR,RAMBHALAY,BILASI TOWN,NEAR BAIDYANATH CINEMA HALL,DEOGHAR,JHARKHAND-814112
Email ID07rohitthakur@gmail.com
Mobile No9102732820
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 145.83
2 Plot area as per Document by Applicant 145.83
3 Physical area measured at site 145.83
4 Area as per Site Visit (Site Visit Report) 145.83
5Area as per Drawing 145.83

Area of Plot Considered : 145.83

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 145.83
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 145.83
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 128.34
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.49
17.49
Balance Plot Area 128.34

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 102.08
Proposed Coverage Area ( 55.38 % ) 80.76
Total Prop. Coverage Area ( 55.38 % ) 80.76
Balance coverage area ( 14.62 % ) 21.32
FAR CHECK
Perm. FAR Area ( 2.50 ) 364.57
Total Perm. FAR area 364.57
Residential FAR 246.21
Proposed FAR Area 246.21
Total Proposed FAR Area 246.21
Consumed FAR (Factor) 1.69
Balance FAR Area 118.36
BUA CHECK
Total Proposed BuiltUp Area 246.20


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 500 meter and upto 600 meter -
Existing Road Width 15.1 15.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 145.83 145.83


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 145.83 OK
Plot Width Sq.Mt. - - 9.45 OK
Plot Depth Sq.Mt. - - 15.43 OK
Access Width Sq.Mt. - - 15.10 OK
Plot Frontage Sq.Mt. - - 9.30 OK
Coverage Area Sq.Mt. - 102.08 80.76 OK
FAR Area Sq.Mt. - 364.57 246.21 OK
Consumed FAR Sq.Mt. - 2.50 1.69 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 14.58 17.49 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 17.49 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.41 OK
Tree Cover (Plantation) - Angle Degree - 89.19 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 15 OK
A-1 (SRI ROHIT KUMAR) Front Margin... 15.1 MTR WIDE ROAD Access Road Mt. 2.50 - 2.62 OK
Rear Margin Mt. 1.50 - 1.53 OK
Side1 Margin Mt. 0.90 - 0.92 OK
Side2 Margin Mt. - - 0.80 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI ROHIT KUMAR) Height Mt. 25.27 8.61 OK
A (SRI ROHIT KUMAR) Second Floor - Height Mt. 2.75 - 2.87 OK
First Floor - Height Mt. 2.75 - 2.87 OK
Ground Floor - Height Mt. 2.75 - 2.87 OK
Plinth - Height Mt. 0.45 - 0.76 OK
A (SRI ROHIT KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.08 OK
A (SRI ROHIT KUMAR) No. of Floors No. - 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.915 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.151 OK
STAIRCASE - Riser No. On Flight No. - 5 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.915 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.151 OK
STAIRCASE - Riser No. On Flight No. - 5 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.915 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.151 OK
STAIRCASE - Riser No. On Flight No. - 5 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.915 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.235 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.21 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.31 OK
Width Mt. - - 1.21 OK
Depth Mt. - - 1.91 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.96 OK
Width Mt. - - 0.84 OK
Depth Mt. - - 1.15 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)