No Image Found

Detail Scrutiny Report

Deoghar Municipal Corporation

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 19-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District DEOGHAR
Authority DEOGHAR MUNICIPAL CORPORATION
Inward_No DGMC/BP/0075/W27/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Deoghar
Taluka 18
Architect Details
Architect Name UJJAWAL KUMAR
License No. DGMC/ENG/0005/2016
Architect Address INDU BHUSHAN SARKAR ROAD,WILLIAMS TOWN
Architect EmailID ujjawalkmr862@gmail.com
Architect Mobile No 9835573284
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 687
North Plot No. - 689
South Road Width - 4.57
East Plot No. - 27 PART
West Road Width - 4.57
Owner's Details
Name PRABHA DEVI
Address SAHID ASHRAM ROAD DEOGHAR
Email ID UJJAWALKUMAR52@YAHOO.COM
Mobile No 9955941872
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 197.58
2 Plot area as per Document by Applicant 197.58
3 Physical area measured at site 191.93
4 Area as per Site Visit (Site Visit Report) 191.93
5 Area as per Drawing 191.93

Area of Plot Considered : 191.93

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 191.93
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 191.93
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 168.27
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 23.66
23.66
Balance Plot Area 168.27

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 134.35
Proposed Coverage Area ( 63.50 % ) 121.88
Total Prop. Coverage Area ( 63.5 % ) 121.88
Balance coverage area ( 6.50 % ) 12.47
FAR CHECK
Perm. FAR Area ( 1.50 ) 287.89
Total Perm. FAR area 287.89
Residential FAR 160.19
Proposed FAR Area 160.19
Total Proposed FAR Area 160.19
Consumed FAR (Factor) 0.83
Balance FAR Area 127.70
BUA CHECK
Total Proposed BuiltUp Area 247.78


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 4.57 -
Road Widening Width 0 -
Plot size (as per measurement) 191.93 191.93




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 19.19 23.66 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 23.66 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SMT PRABHA DEVI) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SMT PRABHA DEVI) 9.91 6.30 6.30 6.47 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SMT PRABHA DEVI) First Floor 2.75 - 3.15 OK
Ground Floor 2.75 - 3.15 OK
Plinth 0.45 - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SMT PRABHA DEVI) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SMT PRABHA DEVI) G + 2 2 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
134.35 121.88 OK
70% 63.5%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (SMT PRABHA DEVI) - 121.88
Total Prop. Coverage Area - 121.88
Total Coverage Area 134.35 121.88


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (SMT PRABHA DEVI) 1 247.78 87.59 160.19 160.19 160.19 01
Grand Total : 1 247.78 87.59 160.19 160.19 160.19 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SMT PRABHA DEVI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 123.89 36.30 123.89 36.30
First Floor 123.89 123.89 123.89 123.89
Terrace Floor 0.00 0.00 0.00 0.00
Total : 247.78 160.19 247.78 160.19


[-] UnitBUA Table for Building :A (SMT PRABHA DEVI) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT FLAT-A FLAT 119.81 115.15 3 1
FIRST FLOOR PLAN SPLIT FLAT-A FLAT 0.00 0.00 11 0
Total: - - 119.81 115.15 14 1


[-] Building :A (SMT PRABHA DEVI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 123.89 87.59 36.30 36.30 36.30 01
First Floor 123.89 0.00 123.89 123.89 123.89 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 247.78 87.59 160.19 160.19 160.19 01
Total Number of Same Buildings : 1
Total : 247.78 87.59 160.19 160.19 160.19 01

[-] Table 4c-2

FARArea
Building FAR Area : 160.19
Existing FAR Area : 0.00
Perm.
287.89
Prop.
160.19
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SMT PRABHA DEVI) 4.57 mt. Wide MainRoad 3.00 3.05 1.80 1.97 0.90 1.05 - 0.45 OK







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (SMT PRABHA DEVI)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SMT PRABHA DEVI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.988 0.225 0.250 0.200 0.131 - 12 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 0.988 0.225 0.250 0.200 0.131 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.988 - 0.250 - 0.000 - 0 2.100 - 2.525 OK


[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (SMT PRABHA DEVI)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
C.B. 0.60 0.60 - 3.35 - 2.01 OK
FIRST FLOOR PLAN WeatherShed 0.75 0.60 - 4.28 - 2.57 OK
CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
CHHAJJA 0.75 0.45 - 1.05 - 0.47 OK
CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
CHHAJJA 0.75 0.45 - 1.65 - 0.74 OK
C.B. 0.60 0.60 - 3.35 - 2.01 OK

Projection for C.B shall not be allowed in floor immediately above Ground level.


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.18 - - 0.98 - - 2.23 - - 0.00 OK
RAIN WATER HARVESTING - - 2.18 - - 0.98 - - 2.23 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (SMT PRABHA DEVI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 191.93 OK
Plot Width - 9.00 OK
Plot Depth - 21.32 OK
Access Width - 4.57 OK
Plot Frontage - 9.00 OK
Coverage Area 134.35 121.88 OK
FARArea
Bldg. FAR Area : 160.19
Sanctioned FAR Area : 0.00
287.89 160.19 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
(3) No need to check
(4) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
- -
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)