No Image Found

Failed List Report

Deoghar Municipal Corporation

Version Number: 1.0.31
Version Date: 30/06/2018
Report Generated On: 22-01-2019

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District DEOGHAR
Authority DEOGHAR MUNICIPAL CORPORATION
Inward_No DGMC/BP/0068/W24/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Deoghar
Taluka 18
Architect Details
Architect Name ASHOK KUMAR JHA
License No. DGMC/ENG/0002/2017
Architect Address ANKUR PURANDHA PO +PS DEOGHAR
Architect EmailID jhaashok9431158158@gmail.com
Architect Mobile No 9431158158
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No T.P PLOT NO- 31
North Plot No. - LAND OF BASU ROUT
South Plot No. - LAND OF RAM ROUT
East Plot No. - MOUZA BAIDHNATHPUR
West Road Width - 15.20
Owner's Details
Name AJEET KUMAR KESHARI DWARIKA PRASAD SUDHIR KUMAR KESHARI DILIP KUMAR KESHARI NAND GOPAL SAH
Address PREM PRAKASH ANAND JHA PATH JHOUSAGARHI DEOGHAR
Email ID UJJAWALKUMAR52@YAHOO.COM
Mobile No 9771063351
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 2887.26
2 Plot area as per Document by Applicant 2887.26
3 Physical area measured at site 2884.17
4 Area as per Site Visit (Site Visit Report) 2884.17
5 Area as per Drawing 2884.17

Area of Plot Considered : 2884.17

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Multistoried
Building Type Single Detached House
Gross Plot Area 2884.17
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 2884.17
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2442.63
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 441.54
441.54
Balance Plot Area 2442.63

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1442.08
Proposed Coverage Area ( 42.54 % ) 1226.80
Total Prop. Coverage Area ( 42.54 % ) 1226.80
Balance coverage area ( 7.46 % ) 215.28
FAR CHECK
Perm. FAR Area ( 2.50 ) 7210.42
Total Perm. FAR area 7210.42
Residential FAR 7065.10
Proposed FAR Area 7204.43
Total Proposed FAR Area 7204.43
Consumed FAR (Factor) 2.50
Balance FAR Area 5.99
BUA CHECK
Total Proposed BuiltUp Area 12513.72


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 15.2 15.20
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 2884.17 2884.17





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Width The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Depth The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot ; ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Multistoried Building, having Building Height 23.10-30.0 mt.,Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 5.0 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Balcony For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, above G+4 floors or if the number of flats is 16 or more, Mini. 1 Lift shall be required For every 16 flats or part thereof. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp For parking spaces in basements and upper storey of parking floors, at least two ramps of minimum of 3.00m width if it is strait and 3.6 width if it is curved at any point, or one ramp of minimum 4.5 m width and with minimum slope gradient of 1:8 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. In the case of Hospitals, the slope of ramp shall not be greater than 1:20 {As per Rule No. 41.8} ;
Ramp No. (1) No Ramp is required if Car Lift is provided
(2) -
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(8) No need to check distance from Building METER ROOM
(9) No need to check distance from Building ENT.GATE
(10) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(11) No need to check distance from Building GUARD ROOM
(12) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(13) No need to check distance from Building Entrance Lobby
(14) -
(15) No need to check distance from Building SOLAR HEATING SYSTEM
(16) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(17) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)