Topic |
Rule |
Plot Level |
Plot Area
|
The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
|
Plot Width
|
The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
|
Plot Depth
|
The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
|
Access Width
|
The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
|
Plot Frontage
|
The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
|
FAR Area
|
(1)
In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR
|
(1)
In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area
|
In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
|
Common Plot
|
; ;
|
Tree Number
|
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule
|
For Multistoried Building, having Building Height 23.10-30.0 mt.,Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 5.0 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
|
Basement Margin Rule
|
In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
|
Building Level |
Building Height
|
For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
|
Floor Height
|
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
|
Parapet Height
|
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Below GL Floor Height
|
,
|
Basement Floor No.
|
Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
|
Floor Number
|
For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
|
Balcony
|
For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
|
Lift Count
|
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Residential Building height 12.0 mt. or above, above G+4 floors or if the number of flats is 16 or more, Mini. 1 Lift shall be required For every 16 flats or part thereof. {As per Rule No. 49.1.2}
|
Lift
|
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5)
-
|
StairCase
|
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4)
; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5)
No Rule Defined
(6)
; No Rule Defined
(7)
No Rule Defined
(8)
; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
|
Ramp
|
For parking spaces in basements and upper storey of parking floors, at least two ramps of minimum of 3.00m width if it is strait and 3.6 width if it is curved at any point, or one ramp of minimum 4.5 m width and with minimum slope gradient of 1:8 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. In the case of Hospitals, the slope of ramp shall not be greater than 1:20 {As per Rule No. 41.8} ;
|
Ramp No.
|
(1)
No Ramp is required if Car Lift is provided
(2)
-
|
Arch Projection
|
(1)
No need to check
(2)
Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
|
Plot / Building Level |
Accessory Use
|
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet
(3)
-
(4)
No need to check distance from Building SUMP TANK
(5)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6)
No need to check distance from Building RAIN WATER HARVESTING
(7)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(8)
No need to check distance from Building METER ROOM
(9)
No need to check distance from Building ENT.GATE
(10)
Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(11)
No need to check distance from Building GUARD ROOM
(12)
Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(13)
No need to check distance from Building Entrance Lobby
(14)
-
(15)
No need to check distance from Building SOLAR HEATING SYSTEM
(16)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(17)
No need to check distance from Building Generator Room
|
Accessory Use Number
|
(1)
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2)
Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |