No Image Found   

Detail Scrutiny Report

Deoghar Municipal Corporation

Version Number: 1.0.42  
Version Date: 29/04/2019 
Report Generated On: 16-10-2019 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0017/W22/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameALOK KUMAR SINGH
License No.DGMC/ENG/0007/2017
Architect AddressNEAR PRIVATE BUS STAND INFRONT OF RAM RAM JANKI MANDIR
Architect EmailIDaloksingh978@gmail.com
Architect Mobile No8863860908
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No28/A
NorthPlot No. - VENDORS LAND & PART OF S.P PLOT NO.-15
SouthRoad Width - 5.18 M WIDE ROAD
EastRoad Width - 4.57 M WIDE ROAD
WestPlot No. - SUB PLOT NO. 14
Owner's Details
NameMITHILESH KUMAR SINHA
AddressBAMBAM BABA COLONY DEOGHAR JHARKHAND
Email IDsinha.mk174@gmail.com
Mobile No7909028669
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 232.52
2 Plot area as per Document by Applicant 231.39
3 Physical area measured at site 231.39
4 Area as per Site Visit (Site Visit Report) 231.39
5Area as per Drawing 231.39

Area of Plot Considered : 231.39

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 231.39
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 231.39
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 204.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 27.30
27.30
Balance Plot Area 204.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 161.97
Proposed Coverage Area ( 57.98 % ) 134.16
Total Prop. Coverage Area ( 57.98 % ) 134.16
Balance coverage area ( 12.02 % ) 27.81
FAR CHECK
Perm. FAR Area ( 1.80 ) 416.50
Total Perm. FAR area 416.50
Residential FAR 320.71
Proposed FAR Area 320.71
Total Proposed FAR Area 320.71
Consumed FAR (Factor) 1.39
Balance FAR Area 95.79
BUA CHECK
Total Proposed BuiltUp Area 347.09


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.57 5.18
Proposed Road Width as per Master Plan 4.57 -
Road Widening Width 0 -
Plot size (as per measurement) 231.39 231.39

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 11.57 27.30 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 27.30 0.00 0.00 - 2.04 - 89.45 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 13 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MITHILESH KUMAR SINHA) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MITHILESH KUMAR SINHA) 9.01 8.61 8.61 8.61 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MITHILESH KUMAR SINHA) Second Floor 2.75 - 2.87 2.75 - 2.76 2.40 - 2.74 OK
First Floor 2.75 - 2.87 2.75 - 2.76 2.40 - 2.74 OK
Ground Floor 2.75 - 2.87 2.75 - 2.76 2.40 - 2.74 OK
Plinth 0.45 - 0.76 - - 0.76 - - 0.76 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (MITHILESH KUMAR SINHA) Terrace Floor 1.00 1.20 1.04 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MITHILESH KUMAR SINHA) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
161.97 134.16 OK
70% 57.98%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MITHILESH KUMAR SINHA) - 134.16
  Total Prop. Coverage Area - 134.16
  Total Coverage Area 161.97 134.16

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (MITHILESH KUMAR SINHA) 1 347.09 26.38 320.71 320.71 320.71 01
Grand Total : 1 347.09 26.38 320.71 320.71 320.71 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MITHILESH KUMAR SINHA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 134.15 107.77 134.15 107.77
First Floor 134.16 134.16 134.16 134.16
Second Floor 78.78 78.78 78.78 78.78
Terrace Floor 0.00 0.00 0.00 0.00
Total : 347.09 320.71 347.09 320.71


[-] UnitBUA Table for Building :A (MITHILESH KUMAR SINHA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 260.63 260.07 7 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 10 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 5 0
Total: - - 260.63 260.07 22 1


[-] Building :A (MITHILESH KUMAR SINHA)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 134.15 26.38 107.77 107.77 107.77 01
First Floor 134.16 0.00 134.16 134.16 134.16 00
Second Floor 78.78 0.00 78.78 78.78 78.78 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 347.09 26.38 320.71 320.71 320.71 01
Total Number of Same Buildings : 1
Total : 347.09 26.38 320.71 320.71 320.71 01
[-] Table 4c-2

  FAR Area
Building FAR Area:320.71
Existing FAR Area :0.00
Perm.
416.50
Prop.
320.71
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MITHILESH KUMAR SINHA) 4.57 MTR WIDE MAINROAD Access Road 2.50 2.97 1.50 1.54 0.90 1.24 0.90 1.53 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (MITHILESH KUMAR SINHA) BldgLine for 4.57 MTR WIDE MAINROAD Access Road 0.26 2.97 4.57 MTR WIDE MAINROAD Access Road 0.26 0.00 Failed





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (MITHILESH KUMAR SINHA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (MITHILESH KUMAR SINHA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.991 0.250 0.254 0.200 0.151 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 0.991 0.250 0.254 0.200 0.151 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.991 0.250 0.254 0.200 0.151 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.991 - 0.254 - 0.000 - 0 - - 2.535 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.92 - - 0.74 - - 1.25 - - 0.00 OK
RAIN WATER HARVESTING - - 1.13 - - 1.20 - - 1.20 - - 0.00 OK
ENT.GATE - - 2.31 - - 0.59 - - 3.94 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.28 - - 0.85 - - 1.50 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MITHILESH KUMAR SINHA)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 231.39 OK
  Plot Width - 13.86 OK
  Plot Depth - 16.70 OK
  Access Width - 5.18 OK
  Plot Frontage - 16.64 OK
  Coverage Area 161.97 134.16 OK
  FAR Area
Bldg. FAR Area : 320.71
Sanctioned FAR Area :0.00
416.50 320.71 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)