No Image Found   

Detail Scrutiny Report

Deoghar Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 26-01-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0052/W18/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameUJJAWAL KUMAR
License No.DGMC/ENG/0005/2016
Architect AddressINDU BHUSHAN SARKAR ROAD,WILLIAMS TOWN
Architect EmailIDujjawalkmr862@gmail.com
Architect Mobile No9835573284
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoT.P- 777
NorthPlot No. - PLOT NO- B
SouthPlot No. - PLOT NO-D
EastRoad Width - 9.14
WestPlot No. - VENDORS LAND
Owner's Details
NameARVIND KUMAR SINGH
AddressDEOGHAR
Email IDUJJAWALKUMAR52@YAHOO.COM
Mobile No7362875462
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 367.10
2 Plot area as per Document by Applicant 367.10
3 Physical area measured at site 355.26
4 Area as per Site Visit (Site Visit Report) 355.26
5Area as per Drawing 355.26

Area of Plot Considered : 355.26

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 355.26
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 355.26
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 304.92
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 50.34
50.34
Balance Plot Area 304.92

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 213.16
Proposed Coverage Area ( 45.48 % ) 161.59
Total Prop. Coverage Area ( 45.48 % ) 161.59
Balance coverage area ( 14.52 % ) 51.57
FAR CHECK
Perm. FAR Area ( 2.50 ) 888.15
Total Perm. FAR area 888.15
Residential FAR 502.08
Proposed FAR Area 502.08
Total Proposed FAR Area 502.08
Consumed FAR (Factor) 1.41
Balance FAR Area 386.07
BUA CHECK
Total Proposed BuiltUp Area 531.67


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 9.14 9.14
Proposed Road Width as per Master Plan 9.14 -
Road Widening Width 0 -
Plot size (as per measurement) 355.26 355.26
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 17.76 50.34 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 14.02 No Access Provided OK
Normal Open Space - 36.32 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 4 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (FOR ARVIND KUMAR SINGH) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (FOR ARVIND KUMAR SINGH) 23.10 9.60 9.60 9.74 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (FOR ARVIND KUMAR SINGH) Second Floor 2.75 - 3.15 2.75 - 3.03 2.40 - 2.78 OK
First Floor 2.75 - 3.15 2.75 - 3.03 2.40 - 2.78 OK
Ground Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 2.93 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (FOR ARVIND KUMAR SINGH) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (FOR ARVIND KUMAR SINGH) G + 6 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
213.16 161.59 OK
60% 45.48%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (FOR ARVIND KUMAR SINGH) - 161.59
  Total Prop. Coverage Area - 161.59
  Total Coverage Area 213.16 161.59

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Archi.Proj. Resi.
A (FOR ARVIND KUMAR SINGH) 1 531.67 13.95 15.64 502.08 502.08 502.08 01
Grand Total : 1 531.67 13.95 15.64 502.08 502.08 502.08 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (FOR ARVIND KUMAR SINGH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 177.23 156.94 177.23 156.94
First Floor 177.22 172.57 177.22 172.57
Second Floor 177.22 172.57 177.22 172.57
Terrace Floor 0.00 0.00 0.00 0.00
Total : 531.67 502.08 531.67 502.08


[-] UnitBUA Table for Building :A (FOR ARVIND KUMAR SINGH)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT FLAT-1 FLAT 438.69 437.03 13 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT FLAT-1 FLAT 0.00 0.00 14 0
Total: - - 438.69 437.03 41 1


[-] Building :A (FOR ARVIND KUMAR SINGH)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Archi.Proj. Resi.
Ground Floor 177.23 4.65 15.64 156.94 156.94 156.94 01
First Floor 177.22 4.65 0.00 172.57 172.57 172.57 00
Second Floor 177.22 4.65 0.00 172.57 172.57 172.57 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 531.67 13.95 15.64 502.08 502.08 502.08 01
Total Number of Same Buildings : 1
Total : 531.67 13.95 15.64 502.08 502.08 502.08 01
[-] Table 4c-2

  FAR Area
Building FAR Area:502.08
Existing FAR Area :0.00
Perm.
888.15
Prop.
502.08
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (FOR ARVIND KUMAR SINGH) 9.14 mt. Wide MainRoad 4.00 10.65 2.50 3.00 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (FOR ARVIND KUMAR SINGH)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (FOR ARVIND KUMAR SINGH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 1.000 0.250 0.250 0.200 0.092 - 9 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN Staircase -3FL 0.900 1.000 0.250 0.250 0.200 0.088 - 9 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 1.000 - 0.250 - 0.000 - 0 - - 2.525 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (FOR ARVIND KUMAR SINGH)
Floor Name Arch Proj Name Width Status
Perm Prop
GROUND FLOOR PLAN PORTICO - 3.48 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 3.19 - - 1.09 - - 2.92 - - 0.00 OK
RAIN WATER HARVESTING - - 2.43 - - 0.87 - - 2.80 - - 0.00 OK
ENT.GATE - - 0.88 - - 0.19 - - 4.62 - - 0.00 OK
Entrance Lobby - 12.00 4.65 - - 1.50 - - 3.10 - - 0.00 OK
Entrance Lobby - 12.00 4.65 - - 1.50 - - 3.10 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.92 - - 0.95 - - 2.02 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (FOR ARVIND KUMAR SINGH) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (FOR ARVIND KUMAR SINGH)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 355.26 OK
  Plot Width - 12.13 OK
  Plot Depth - 29.30 OK
  Access Width - 9.14 OK
  Plot Frontage - 12.13 OK
  Coverage Area 213.16 161.59 OK
  FAR Area
Bldg. FAR Area : 502.08
Sanctioned FAR Area :0.00
888.15 502.08 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection No need to check
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)