Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (BHUNESHWARI JHA) |
Height |
Mt. |
|
23.10
|
11.48
|
OK
|
|
A (BHUNESHWARI JHA) |
Third Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
Third Floor - Clear Height |
Mt. |
2.75
|
-
|
2.79
|
OK
|
Third Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.57
|
OK
|
Second Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
Second Floor - Clear Height |
Mt. |
2.75
|
-
|
2.79
|
OK
|
Second Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.57
|
OK
|
First Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
First Floor - Clear Height |
Mt. |
2.75
|
-
|
2.79
|
OK
|
First Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.57
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
2.87
|
OK
|
Ground Floor - Clear Height |
Mt. |
2.75
|
-
|
2.79
|
OK
|
Ground Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.57
|
OK
|
Basement Floor - Height |
Mt. |
2.40
|
-
|
2.87
|
OK
|
Basement Floor - Clear Height |
Mt. |
2.40
|
-
|
2.79
|
OK
|
Basement Floor - Beam Clear Height |
Mt. |
2.10
|
-
|
2.57
|
OK
|
|
A (BHUNESHWARI JHA) |
Terrace Floor - Height |
Mt. |
1.00
|
1.20
|
1.07
|
OK
|
|
A (BHUNESHWARI JHA) |
Basement Floor - Height Below GL |
Mt. |
|
-
|
2.26
|
OK
|
Basement Floor - Area |
Sq.Mt. |
|
-
|
185.63
|
OK
|
Basement Floor - Ventilation Area (Sq.mt.) |
Sq.Mt. |
-
|
|
2.54
|
OK
|
|
A (BHUNESHWARI JHA) |
Area |
Sq.Mt. |
|
-
|
185.63
|
OK
|
Status |
|
|
|
-
|
OK
|
Total |
Area |
Sq.Mt. |
|
-
|
185.63
|
OK
|
|
A (BHUNESHWARI JHA) |
No. of Basement Floor |
No. |
|
2
|
1
|
OK
|
|
A (BHUNESHWARI JHA) |
No. of Floors |
No. |
|
G + 6
|
4
|
OK
|
No. of Tenements |
No. |
|
-
|
4
|
OK
|
|
A (BHUNESHWARI JHA) |
Number Of Lift(s) |
No. |
2
|
|
2
|
OK
|
|
A (BHUNESHWARI JHA) |
BASEMENT FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
BASEMENT FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
BASEMENT FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
BASEMENT FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
TYPICAL - 1, 2 & 3 FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
TYPICAL - 1, 2 & 3 FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.92
|
OK
|
TYPICAL - 1, 2 & 3 FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
TYPICAL - 1, 2 & 3 FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.90
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
2.02
|
OK
|
|
BASEMENT FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.046
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.254
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
GROUND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.046
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.254
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.103
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
4
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TYPICAL - 1, 2 & 3 FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.046
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.254
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.103
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
4
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
-
|
|
1.046
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
-
|
|
0.254
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
2.816
|
OK
|
|
Toilet |
Area |
Sq.Mt. |
-
|
5.00
|
2.73
|
OK
|
Width |
Mt. |
-
|
-
|
1.52
|
OK
|
Depth |
Mt. |
-
|
-
|
1.80
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Sewage Treatment Plant |
Area |
Sq.Mt. |
-
|
-
|
0.94
|
OK
|
Width |
Mt. |
-
|
-
|
0.81
|
OK
|
Depth |
Mt. |
-
|
-
|
1.15
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
RAIN WATER HARVESTING |
Area |
Sq.Mt. |
-
|
-
|
2.38
|
OK
|
Width |
Mt. |
-
|
-
|
1.41
|
OK
|
Depth |
Mt. |
-
|
-
|
1.69
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
ENT.GATE |
Area |
Sq.Mt. |
-
|
-
|
0.91
|
OK
|
Width |
Mt. |
-
|
-
|
0.36
|
OK
|
Depth |
Mt. |
-
|
-
|
2.56
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Area |
Sq.Mt. |
-
|
-
|
0.91
|
OK
|
Width |
Mt. |
-
|
-
|
0.36
|
OK
|
Depth |
Mt. |
-
|
-
|
2.56
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SOLAR HEATING SYSTEM |
Area |
Sq.Mt. |
-
|
-
|
1.08
|
OK
|
Width |
Mt. |
-
|
-
|
1.04
|
OK
|
Depth |
Mt. |
-
|
-
|
1.05
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
Generator Room |
Area |
Sq.Mt. |
-
|
-
|
2.73
|
OK
|
Width |
Mt. |
-
|
-
|
1.52
|
OK
|
Depth |
Mt. |
-
|
-
|
1.80
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
|
A (BHUNESHWARI JHA) |
Rain Water Harvesting - No |
No. |
1
|
-
|
1
|
OK
|
Entrance Gate - No |
No. |
1
|
-
|
2
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use
|
Plot Width |
No rule provided for Min. Plot size for proposed Use
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use
|
Access Width |
The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use
|
FAR Area |
(1)
In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Consumed FAR |
(1)
In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 10-15 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
|
Basement Margin Rule |
In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
|
Building Level |
Building Height |
For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Below GL Floor Height |
,
|
Basement Floor No. |
Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
|
Floor Number |
For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
|
Lift Count |
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Lift |
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5)
-
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet
(3)
-
(4)
No need to check distance from Building Sewage Treatment Plant
(5)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6)
No need to check distance from Building RAIN WATER HARVESTING
(7)
No need to check distance from Building ENT.GATE
(8)
-
(9)
No need to check distance from Building SOLAR HEATING SYSTEM
(10)
Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11)
No need to check distance from Building Generator Room
|
Accessory Use Number |
(1)
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2)
In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
|
Building Level (Rooms) |
|