-
No Image Found   

Check List Report

Deoghar Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 09-11-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0117/W17/2021/REV1
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentRevision
Revise Case TypeBefore 15th Sept 2004
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameSHANKAR PRASAD SINGH
License No.DGMC/ENG/0007/2018
Architect Address52 BIGHA,RED ROSE SCHOOL ROAD,BEHIND OF MAA LALITA HOSPITAL
Architect EmailIDshivconstruction555@gmail.com
Architect Mobile No8340525212
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No94
NorthPlot No. - LAND OF SMT SONA DEVI
SouthPlot No. - LAND & HOUSE OF SRI MOTILAL
EastRoad Width - 4.57 WIDE ROAD
WestRoad Width - 12.20 WIDE ROAD
Owner's Details
NameSMT SAROJNI DEVI
AddressNEAR BOMPASS TOWN KHORADAH
Email IDshivconstruction555@gmail.com
Mobile No9470281961
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 931.97
2 Plot area as per Document by Applicant 931.97
3 Physical area measured at site 931.90
4 Area as per Site Visit (Site Visit Report) 931.90
5Area as per Drawing 929.83

Area of Plot Considered : 929.83

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 929.83
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 929.83
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 834.14
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 95.69
95.69
Balance Plot Area 834.14

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 557.90
Proposed Coverage Area ( 54.71 % ) 508.74
Total Prop. Coverage Area ( 54.71 % ) 508.74
Balance coverage area ( 5.29 % ) 49.16
FAR CHECK
Perm. FAR Area ( 2.500 ) 2324.57
Total Perm. FAR area 2324.57
Residential FAR 1789.24
Proposed FAR Area 1813.66
Total Proposed FAR Area 1813.66
Consumed FAR (Factor) 1.95
Balance FAR Area 510.91
BUA CHECK
Total Proposed BuiltUp Area 2676.77


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 12.2 -
Road Widening Width 0 -
Plot size (as per measurement) 931.9 929.83
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 929.83 OK
Plot Width Mt. - - 13.22 OK
Plot Depth Mt. - - 70.33 OK
Access Width Mt. 6.10 - 12.20 OK
Plot Frontage Mt. - - 10.18 OK
Coverage Area Sq.Mt. - 557.90 508.74 OK
FAR Area Sq.Mt. - 2324.57 1813.66 OK
Consumed FAR Sq.Mt. - 2.50 1.95 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 92.98 95.69 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 95.69 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.98 OK
Tree Cover (Plantation) - Angle Degree - 83.59 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
Car In Area Sq.Mt. - - 150.00 OK
Two Stack.Car In Area Sq.Mt. - - 125.00 OK
Total Car In Area Sq.Mt. 250.00 - 275.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 25.00 OK
Total Visitor Parking In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 50.00 OK
Total TwoWheeler In Area Sq.Mt. 40.00 - 50.00 OK
Other Parking In Area Sq.Mt. - - 317.66 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 3.70 OK
PLOT - - - DRIVEWAY - Width No. 3.60 - 3.70 OK
PLOT - - - DRIVEWAY - Width No. 3.00 - 3.05 OK
A ( SMT SAROJNI DEVI) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.85 OK
A-1 ( SMT SAROJNI DEVI) Front Margin... 12.20 MTR WIDE MAINROAD Access Road Mt. 6.00 - 6.00 OK
Rear Margin Mt. 5.00 - 5.05 OK
Side1 Margin Mt. 1.00 - 1.63 OK
Side2 Margin Mt. 1.00 - 1.98 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A ( SMT SAROJNI DEVI) Height Mt. 24.30 15.00 OK
A ( SMT SAROJNI DEVI) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.90 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.75 OK
Plinth - Clear Height Mt. - - 0.75 OK
Plinth - Beam Clear Height Mt. - - 0.75 OK
A ( SMT SAROJNI DEVI) Terrace Floor - Height Mt. - - 1.04 OK
Terrace Floor - Clear Height Mt. - - 1.04 OK
Terrace Floor - Beam Clear Height Mt. - - 1.04 OK
A ( SMT SAROJNI DEVI) No. of Floors No. - 5 OK
No. of Tenements No. - 20 OK
A ( SMT SAROJNI DEVI) FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.95 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.81 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.93 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.95 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.81 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.93 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.95 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.81 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.93 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.95 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.81 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.93 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.125 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.150 OK
Fire Escape Staircase - Riser No. On Flight No. 16 3 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TYPICAL - 2, 3 & 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.125 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.150 OK
Fire Escape Staircase - Riser No. On Flight No. 16 3 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.125 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.150 OK
Fire Escape Staircase - Riser No. On Flight No. 16 3 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.125 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.594 OK
Fire Escape Staircase - Flight Width Mt. - 1.200 OK
Fire Escape Staircase - Tread Width Mt. - 0.250 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.594 OK
Toilet Area Sq.Mt. - 5.00 1.42 OK
Width Mt. - - 1.16 OK
Depth Mt. - - 1.22 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.97 OK
Width Mt. - - 1.49 OK
Depth Mt. - - 2.67 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.88 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.55 OK
Width Mt. - - 1.49 OK
Depth Mt. - - 1.72 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.52 OK
Width Mt. - - 0.52 OK
Depth Mt. - - 2.94 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 3.88 OK
Width Mt. - - 1.97 OK
Depth Mt. - - 1.97 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 9.19 OK
Width Mt. - - 2.43 OK
Depth Mt. - - 3.79 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.62 OK
Width Mt. - - 2.12 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.49 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 5.28 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.38 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.10 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 5.64 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 3.14 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 5.73 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 3.19 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.19 OK
Width Mt. - - 2.43 OK
Depth Mt. - - 3.79 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.62 OK
Width Mt. - - 2.12 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.49 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 5.28 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.38 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.10 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.86 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 5.64 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 3.14 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 5.73 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 3.19 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.44 OK
Width Mt. - - 1.49 OK
Depth Mt. - - 1.64 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 2.50 OK
Width Mt. - - 1.46 OK
Depth Mt. - - 1.72 OK
Height Mt. - - - OK
A ( SMT SAROJNI DEVI) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 10-15 mt., Margin required in Front shall be 6.0 mt., Rear 5.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building Entrance Lobby
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
(14) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(15) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)