General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0043/W16/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameUJJAWAL KUMAR
License No.DGMC/ENG/0005/2016
Architect AddressINDU BHUSHAN SARKAR ROAD,WILLIAMS TOWN
Architect EmailIDujjawalkmr862@gmail.com
Architect Mobile No9835573284
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoTPP NO.- 262
NorthPlot No. - SUB PLOT NO.- 5
SouthPlot No. - VENDOR'S LAND
EastPlot No. - LAND OF SOBHA DEVI
WestRoad Width - 3
Owner's Details
NameSMT SANGITA JHA SRI CHANDRA SHEKHAR JHA
AddressSALONATAND WILLIAMS TOWN DEOGHAR
Email IDujjawalkmr862@gmail.com
Mobile No9308082771
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 214.61
2 Plot area as per Document by Applicant 214.61
3 Physical area measured at site 207.92
4 Area as per Site Visit (Site Visit Report) 207.92
5Area as per Drawing 207.92

Area of Plot Considered : 207.92

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 207.92
Deduction from Gross Plot area
- Road Widening Area 7.56
7.56
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 200.36
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 152.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 7.56
- Common Plot 48.27
55.83
Balance Plot Area 152.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 140.25
Proposed Coverage Area ( 38.14 % ) 76.41
Total Prop. Coverage Area ( 38.14 % ) 76.41
Balance coverage area ( 31.86 % ) 63.84
FAR CHECK
Perm. FAR Area ( 1.20 ) 240.43
Total Perm. FAR area 240.43
Residential FAR 167.81
Proposed FAR Area 167.81
Total Proposed FAR Area 167.81
Consumed FAR (Factor) 0.84
Balance FAR Area 72.62
BUA CHECK
Total Proposed BuiltUp Area 182.80


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 3.05 -
Road Widening Width 0 0.60
Plot size (as per measurement) 207.92 207.92
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.02 48.27 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 48.27 0.00 0.00 - 3.45 - 89.13 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 2 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) 6.00 6.11 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) G + 1 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
140.25 76.41 OK
70% 38.14%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) - 76.41
  Total Prop. Coverage Area - 76.41
  Total Coverage Area 140.25 76.41

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Archi.Proj. Resi.
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) 1 182.80 14.99 167.81 167.81 167.81 01
Grand Total : 1 182.80 14.99 167.81 167.81 167.81 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 91.40 76.41 91.40 76.41
First Floor 91.40 91.40 91.40 91.40
Terrace Floor 0.00 0.00 0.00 0.00
Total : 182.80 167.81 182.80 167.81


[-] UnitBUA Table for Building :A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT F1 FLAT 0.00 0.00 8 0
GROUND FLOOR PLAN SPLIT F1 FLAT 134.27 133.98 5 1
Total: - - 134.27 133.98 13 1


[-] Building :A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Archi.Proj. Resi.
Ground Floor 91.40 14.99 76.41 76.41 76.41 01
First Floor 91.40 0.00 91.40 91.40 91.40 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 182.80 14.99 167.81 167.81 167.81 01
Total Number of Same Buildings : 1
Total : 182.80 14.99 167.81 167.81 167.81 01
[-] Table 4c-2

  FAR Area
Building FAR Area:167.81
Existing FAR Area :0.00
Perm.
240.43
Prop.
167.81
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) ROAD WIDENING AREA 2.50 3.55 1.50 2.33 0.90 3.93 0.90 0.92 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) BldgLine for 3.05 mt. Wide MainRoad 0.27 4.15 3.05 mt. Wide MainRoad ROAD WIDENING AREA 0.27 0.60 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN Staircase -4FL 0.750 0.900 0.225 0.250 0.200 0.079 - 5 - - 0.000 OK
GROUND FLOOR PLAN Staircase -4FL 0.750 0.900 0.225 0.250 0.200 0.079 - 5 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -4FL - 0.900 - 0.250 - 0.000 - 0 2.100 - 2.525 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)
Floor Name Arch Proj Name Width Status
Perm Prop
GROUND FLOOR PLAN PORTICO - 3.03 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SEPTIC TANK - - 1.07 - - 0.69 - - 1.57 - - 0.00 OK
RAIN WATER HARVESTING - - 1.07 - - 0.69 - - 1.57 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.07 - - 0.69 - - 1.57 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (FOR CHANDRA SHEKHAR JHA AND SANGITA JHA)


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 200.36 OK
  Plot Width - 12.70 OK
  Plot Depth - 15.78 OK
  Access Width - 3.05 OK
  Plot Frontage - 12.60 OK
  Coverage Area 140.25 76.41 OK
  FAR Area
Bldg. FAR Area : 167.81
Sanctioned FAR Area :0.00
240.43 167.81 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection No need to check
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)